Vallox 1992 A Instructions For Installation And Use Manual

Page 1
Room by room ventilation system
In buildings with room by room ventilation the user can influence the level of ventilation. Ventilation can be adjusted in accordance with usage with the ventilation regulator.
Normal operation (position 2 or 3)
Ventilation has to be continual, i.e. air volume in the dwelling has to be exchanged at least every two and a half hours.
Absence operation (position 1)
When the room is empty, ventilation can be adjusted lower than the normal operation position unless it is harmful for the building structures or ventilation system.
Boosted operation (positions 3 and 4)
Cooking, bathing in the sauna or bathroom, drying clothes, using the toilet, having guests, overheat or a similar situation in dwellings may cause a need for higher than normal ventilation. In other rooms, ventilation is boosted in accordance with the usage of the room.
NOTE! Electrical connections must be carried out by an authorised
person only. In case of failure with the control centre, contact the seller or
manufacturer of the device.
NOTE! Carefully push the tongues inwards.
In flush mounting, maximum installation depth is 55 mm.
© VALLOX • We reserve the right to make changes without prior notification. www.vallox.com
SEPARATE CONTROL CENTRE
Use of ventilation
INSTRUCTIONS FOR INSTALLATION AND USE
Operating switch of the control centre:
NOTE! In fans that are controlled with the control panel, a
motor protector is needed. The maximum output of the fan is 340 W.
Follow the ventilation plan that states the position of the regulator in normal living conditions in order to ensure proper air circulation.
Installation
1. Open the cover of the control centre with e.g. a screwdriver.
2. Mark the locations for the fixing screws.
3. Fasten the control panel to the wall with the fixing accessories provided in the kit. (Fixing screws are suitable for wooden, chipboard, concrete and masonry walls; for other surfaces, use appropriate fixing accessories.)
If ventilation of a room is closed, it also prevents new, clean outdoor air from coming in to the house and dirty air from going out. Impurities emanating from human bodies, structures and the soil, such as carbon dioxide, humidity, smells, formaldehyde, dust and radon, quickly spoil indoor air and cause health damage. Too high a humidity may destroy the building structures and cause mould and fungus growth. Therefore, the building regulations require ventilation to be continually in operation and the level of ventilation to be adjusted as needed by the user.
WARNING
Ventilation switch and regulator rotary actuated regulator
For instance in dwellings
0. Ventilation not active
1. Absence position
2. Normal position
3. Boost position
4. Peak boost position
90
140
55
110
• 1.09.340E
• 25.1.2008 © VALLOX
Page 2
© VALLOX • We reserve the right to make changes without prior notification.
www.vallox.com
1.09.340E/25.1.2008/PDF
L
N
W2
U2
V1
V2
U1
W1
L2
N
ROOF VENTIILATORS: VALLOX 15P-2-1 VALLOX 20P-2-1 VALLOX 22P-2-1
L2
N
ROOF VENTILATOR
VALLOX 25P-4-1
L2
DISTRIBUTION PANEL
L
N
PE
N
3*1.5 S
10A
L
3
L
N
N
L
2
3*1.5 S
CONTROL CENTRE VALLOX 1992 A
3*1.5 S
N
ATTIC FAN
L2
N
3*1.5 S
VALLOX 70
N
L3 L2
N
L
3
L
N
N
L
2
L
L
1
DISTRIBUTION PANEL
PE
N
L
10A
DISTRIBUTION PANEL
PE
N
L
L3
L3
VALLOX 75/95
L2
N
L
L
N
N
1
L
L2
N
L
L
5*1.5 S
N
5*1.5 S
10A
L
LN
3*1.5 S
3*1.5 S
CONTROL CENTRE VALLOX 1992 A
N
L
3
L
N
N
L
2
M
120 V
90 V
70 V
230 V
135 V 160 V 180 V
3
2
1
4
0
110 V
f
b
62
3
4
5
Vallox Oy FIN-32200 Loimaa Finland Telephone +358 2 7636 300 Fax +358 2 7631 539
www.vallox.com
CONTROL CENTRE 1992 A
ELECTRICAL DIAGRAMS
Internal electrical connection / Control centre 1992
External electrical coupling / Distribution panel – ventilation unit – control centre
External electrical connection / Distribution panel – control centre – roof ventilator