TALKBACK INTERCOM SYSTEM
V-2925A - ADD ON EXPANSION UNIT
FOR THE V-2924A
The basic V-2924A Talkback Intercom System provides 24 stations with one-way, two-way, group call and all call pages. The V-2925A Expansion Unit is an add on unit for the V-2924A. Each V-2925A Expansion Unit will expand the V-2924A by twenty-four (24) additional stations. Up to three (3) Expansion Units can be added to a system for a total of 48, 72, or 96 zones of paging.
The V-2925A can ONLY be used with the V-2924A. If you have the V-2924 model, please contact Technical Support for assistance.
WARNING: Disconnect main power before servicing. Mounting
Plug the Expansion Unit into the Control Unit. For the first Expansion Unit, insert the P1 connector from the
Expansion Unit into the P8 connector on the Control Unit (Refer to Figure 1 for location of connectors). (For each additional Expansion Unit, insert P2 into P1 – Refer to Figure 1 of the Control Unit document).
Close latches attached to the top and bottom of the Expansion Unit over the keepers on the top and b ottom of
the Control Unit.
Drill holes into backboard through mounting flanges on the Expansion Unit.
Insert screws into ho les and tighten screws firmly.
Connections
Each Expansion Unit requires (2) 66B type punchdown blocks. Mount these on the backboard near the associated Expansion Unit. Make connections to the punchdown blocks as specified in Figure 2 – Punchdown Block Connections.
Setting Option Switches
All options programmed for the Control Unit are available on the additional stations provided by the Expansion Units. The only switches on the Expansion Unit requiring attention are those for Background Music. Refer to Figure 1 for location and Table 1 for the default values of these switches. Make changes as desired for the various zones.
Dimensions/Weight
17.5”H x 8.37”W x 3.06”D
(44.45cm H x 21.26cm W x 7.77cm D)
11 lbs. (5.0 kg)
Operation
Same as Control Unit.
V-2924A with V-2925A Expansion Unit.
1 947212
FIGURE 1 - V-2925A CONTROL AND CONNECTOR LOCATIONS
Side View Top View
P1
P1
P4
P2
SW1
P3
Power LED
Connectors: P1
- Connects to the V-2924A Contro l Unit
P2
- Connects to an additional V-2925A Expansion Unit
P3
- Switch Inputs
P4
- Speaker Outputs
AC Power
115/230 Switch
Fuse
Battery Backup Connector
Switches: SW1 - BGM Group Select Dip Switch (See Table)