INTRODUCTION
These instructions contain the specifications and information necessary to install, operate, and maintain the VPB-260, Battery Back-up Power Supply.

SPECIFICATIONS

The VPB-260 provides a battery source to permit system operation in the event of an AC power failure.
Features
12 and 24 volt DC outputs
Outputs fused at 3 amps
AC input fuse protected
Power on LED indication
Full current limiting on battery charger
Long life Gel Cell Batteries
Battery test switch with light indication
Capacity
Table 1 shows the approximate times for a fully charged supply to reach 90% voltage under different load conditions.
NOTE: All electronic key systems will begin to operate intermittently below a certa in input voltage. Typically reliable operation will be maintained to 90% of full voltage.
Table 1
Discharge Current vs. Time
Current Time
2.5 Amps 1 hr. 40 min. 1 Amp 4 hours
.5 Amp 10 hours
.325 Amp 20 hours
VSP-VPB-260
Issue 5
Applications
The VPB-260 is known to be compatible with the following systems: Telephone Systems: CMX CKS-308
CKS-616 CKS-408/816/1224
Gaitronics Cohort 616 Sanyo EKS 6120 Tie EK-612
Modkey 16 Modkey 1032 DS-01 Onyx VS
Executone Encore CX 512
Encore CX 816
Premier Telecom Siemans Telplus
Trillium Panther 612
Vodavi Starplus 308EX
1A2 Telplus 816 Telplus 1224
Panther 1032 Panther II (820)
Starplus 616EX Starplus 1224EX
(see Application Note)
(reverse 12V & 24V leads)
(WA-260T may be required)
(WA-260P required)
(WA-260P required)
(WA-260P required)
Valcom Page Cont rols V-2001, V-2001A, V-2003, V-2003A, V-2003HF, V-2003AHF, V-2006, V-2006A, V-2006HF, V-2006AHF, V-2901, V-2901A, V-2904, V-2920, V-2924
1 947260
Dimensions/Weight
9.25" H x 7.5" W x 5.25" D
(23.5cm H x 19.05cm W x 13.3cm D)
19 lbs (8.6 kg)
INSTALLATION
Mounting
Using the appropriate hardware, mount the VPB-260 within 6 feet of an AC receptacle.
Specifications
Output 24 Vdc and 12 Vdc fused at 3 amps each
Current limited, constant voltage charger
Gel Cell no maintenance type batteries
Typical battery life is 3-5 years
Power Requirements
Input 105-120 Vac, 60 Hz
Environment
Temperature 0 to 50 Degrees C
Humidity 0 to 85% non-precipitating

DESIGN

The VPB-260 is a fully filtered battery back-up power supply. The input and both outputs are fuse protected. The charger circuit output is floating with respect to ground. The charging circuit provides a constant voltage and is current limited to 1.5 amps to the two Gel Cells. There is a "power on" LED that is illuminated when the supply is connected to the AC power source. There is also a test button for testing the batteries. When pressing this button, the LED will illuminate if the batteries are fully charged.
Connections
Unplug the KSU power cord. Consult the installation manual of the key system for the location of the input socket for the battery backup supply. Plug the low voltage power cord of the auxiliary power system into the socket.
NOTE: The plug is polarized and will only fit one way. After making sure that the plug is seated in the socket, plug in the AC power cords. Both the AC power cord for the VPB-260 and the power cord for the KSU should use the same AC outlet. Figure 1
shows low voltage plug outputs.
NOTE: Time to reach a full charge after initial installation or after a deep discha rge is approximately 9 hours.

MAINTENANCE

In order to insure proper operation of the battery supply, the following operation should be performed once a month.
Unplug the key system from the AC power receptacle to allow operation from the batteries for 15 minutes. Plug key system power cord into AC outlet.
Figure 1: Low Voltage Plug Outputs
24VDC
12VDC

TECHNICAL ASSISTANCE

When trouble is reported, verify that AC power is being supplied to the unit and there are no blown fuses. To test the batteries for full charge, unplug the VPB-260 and press the button marked test on the side of the unit. The LED lights when batteries are okay. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM and a test set available and be calling from the job site. Call (703) 427-3900 and ask for Technical Support, or (540) 427-6000 for Valcom 24-hour Automated Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person, and the nature of the problem. Send the unit to: