The VIP-480L IP Paging Horn is a self contained
paging system which enables voice paging up to
1200 feet from an Ethernet connection. The
VIP-480L consist of a high efficiency 3 Watt
Class-D Horn and a VIP-LLE Network Extender
allowing stand alone capability when used with a
SIP Phone System or can be accessed from a
variety of Valcom managed VoIP products.
SPECIFICATIONS
Access Methods
PBX, FXO Port w/VIP-811
POTS telephone set w/VIP-811
PBX, FXS Port w/VIP-821
Valcom M Cast Page Group
SIP telephone system
Features
RJ-45 network connection
LED Status Indicator
Network activity LEDs
Power over Ethernet (PoE) 802.3af compatible
High Efficiency Class-D 3 Watt Amplifier
Dimensions/Weight
(HORN)
6.8”H x 8.3”W x 3.3” D
(17.3cm H x 21.1cm W x 8.4cm D)
2.1 lbs. (0.95 kg)
Network Extender
(VIP-LLE)
1.30” H x 6.10" W x 6.00" D
(3.51 cm H x 15.72 cm W x 13.51 cm D)
Weight: 0.85 lbs. (0.39 kg)
ISSUE 4
Nominal Specifications – HORN
Input Impedance: 600 Ohms
Input Level: -10dBm
Nominal Specifications – VIP-LLE
Via 802.3af PoE Ethernet Switch:
Class 3 (12.95W)
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference in which case
the user will be required to correct the
interference at his own expense.
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electric shock,
Refer servicing to qualified service personnel.
Do not remove cover.
No user serviceable parts inside.
This symbol indicates that dangerous
voltage constituting a risk of electric
shock is present within this unit.
This symbol indicates that there are
important operating and maintenance
instructions in the literature accompanying
this unit.
Mounting (VIP-LLE)
The VIP-LLE Network Extender is designed for wall
or shelf mounting and must be within 300 feet of the
network switch.
Shelf: Provided with the VIP-LLE Network Extender
are four rubber stick on pads. Peel pads off their
carrier backing and place at the four corners of the
bottom of the unit.
Wall: Using the brackets and wood screws
provided, secure the VIP-LLE Network Extender
to the wall.
Mounting (horn)
FLUSH MOUNT
The cardboard packing material in which the horn is
shipped also serves as the template for flush
mounting. Using the template, draw the speaker
outline on the wall to be cut. Make appropriate
wiring connections and test the speaker for
operation. Using appropriate mounting screws
(not furnished) drill and mount the flange as
shown.
UNIVERSAL BRACKET
Loosen or separate the universal bracket leaves
by loosening or removing the handle and
hardware. Using the back leaf as a template,
mark the wall through the mounting holes. Drill
and mount to the wall using appropriate screws
(not furnished) or mount directly to a junction box.
Mount the T-bracket to the back of the horn as
shown using the (2) ½ inch screws provided.
“C” CLAMP FOR “I” BEAM MOUNTING
A “C” clamp is provided with the horn to allow
mounting to a beam. Attach the “C” clamp to the
back of the horn as shown using the (2) ½ inch
screws provided. Place the bolt through the hole
in the bottom of the base to secure the “C” clamp
to the beam. It is suggested that the horn be
mounted to the underside of the “I” beam to
provide maximum positioning adjustments.
Interconnections
The only method of powering a VIP-480L IP
Paging Horn is via a Power over Ethernet (PoE)
switch or power injector meeting the 802.3af
specification.
Make all required signal connections before
connecting to Ethernet switch or power injector
meeting the 802.3af specification. Power is
supplied to the horn assembly via the
VIP-LLE Network Extender.
Network Connection
As shown in Figure 1, the LLE Network Extender
has one RJ-45 network connector on the front
panel. Use a standard Ethernet patch cable to
connect the NETWORK connector of the LLE
Network Extender to a 802.3af compliant PoE port
(300 feet maximum distance).
Signal Connections
As shown in Figure 1 and 2, audio output
connections are made on the rear panel of the
LLE Network Extender. Versions of the LLE
Network Extender with the color-coded, 8-pin
screw connector will connect standard CAT-5
twisted-pair cable from the rear panel color coded
connector of the LLE Network Extender to the
supplied VM-186 RJ-45 connector (900 feet
maximum distance). Connect RJ-45 connector
of horn to VM-186 RJ-45 socket.
2
Page 3
For versions of the LLE Network Extender with the
RJ-45 Audio Output connector, the horn may be
connected directly to the RJ-45 port. If additional
length is required, any standard T568A or T568B
extension may be used (900 feet maximum).
Setup
Information specific to your application will need to
be programmed into the VIP-480L using a
computer. The PC used for programming should be
connected to the same subnet as the VIP-480L.
Setup will be done using the IP Solutions Setup
Tool. The IP Solutions Setup Tool may be
downloaded from the Valcom website at
www.valcom.com.
Status Indicator Lights
The VIP-LLE Network Extender has 3 status
indication lights:
STATUS: Flashes during normal operation, and
solid when unit in reset.
LINK: Indicates 100 Mbit Ethernet connection when
illuminated. No activity indicates 10 Mbit
connection.
ACT: Indicator flashes to indicate network activity.
Operation:
Provides paging from SIP connection or from
another Valcom VIP unit. Interface to customer
telephone system can be via SIP registration,
FXO port (with VIP-811), or FXS port (with
VIP-821).
TECHNICAL ASSISTANCE
Assistance is available from the factory when
problems are encountered. Call (540) 563-2000
and press 1 for Technical Support or visit our
website at http://www.valcom.com
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
Valcom, Inc. warrants its products only to the original purchaser, for its own use, to be free from defects in materials and workmanship under conditions of
normal use and service for a period of one year from the date of shipment. This Limited Warranty obligation shall be limited to the replacement, repair or
refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units 'out of warranty' are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This Limited Warranty is in lieu of and excludes all other warranties, expressed or implied and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation,
maintenance, installation, removal or use of the product. The maximum liability of Valcom under this warranty is limited to the purchase price of the
specific Product covered by the warranty.
Disclaimer. Except for the Limited Warranty provided herein, the product is provided “as-is” without any warranty of any kind whatsoever including, without
limitation, any WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified
immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
VALCOM LIMITED WARRANTY
Headquarters:
Valcom, Inc.
5614 Hollins Road Roanoke, VA 24019-5056
Phone: (540) 563-2000 FAX: (540) 362-9800
3
Page 4
There are two versions of the VIP-LLE.
Refer to the diagram below that corresponds to the version being installed.
Note: The scr e w terminals are removable.
Gently lift away from the circuit board to
remove. Make the necessary wire connections,
Paging Horn
W/BL W/O W/GN W/BR
Status
Link
Act
then replace the screw terminals over the pins
on circuit board.
Front View
802.3af Compliant PoE Network Po r t
ALCOM
V
VIP-LLE
WHITE/BROWN
WHITE/GREEN
RJ45
BROWN
GREEN
BLUE
WHITE/BLUE
Rear View with Screw Terminal Connector
WHITE/ORANGE
NOT USED
900' MAX DISTANCE
CAT 3/5/6
Note: The Brown and White/brown pair should
be twisted together and inserted into the
connector noted on the drawing and the Green
and White/Green pair should also be twisted
together and inserted into the connector that is
noted on the drawing.
VM-186
BROWN
BLUE
BROWN
WHITE/BROWN
GREEN
WHITE/GREEN
ORANGE
WHITE/ORANGE
BLUE
WHITE/BLUE
Figure 1. (VIP-LLE ve rsions with 8-pin scr ew terminal output connector.)
AUDIO OUTPUT
Rear View with RJ-45 Connector
Figure 2. (VIP-LLE versions with RJ-45 output connector.)
If using the VM-186 or other patch panel to extend the connection between the VIP-LLE (with RJ-45 connector)
and the Paging Horn, use standard T568B wiring connections.
IP Paging Horn
4
Page 5
UNIVERSAL BRACKET
SURFACE MOUNTED WITH A
UNIVERSAL MOUNTING BRACKET
"C" CLAMP FOR "I" BEAM MOUNTING
ATTACH CLAMP TO HORNATTACH FLEXHORN TO BEAM
FLUSH MOUNT USING MO UNTING SCREWS:
USING THE TEMPLATE, MARK LOCATION OF
OPENING AND MOUNTING HOLES ON WALL.
DRILL HOLES APPROPRIATE TO MOUNTING
HARDWARE AND CUT OUT THE OPENING.
HOLDING FLEXHORN FIRMLY AGAINST A FLAT
SURFACE, DRILL THROUGH EACH MOUNTING BOSS
AS SHOWN.
UNIVERSAL BRACKET WITH CLAMP
FLUSH MOUNTING IN A STUD WALL
INSTALLED WITH MOUNTING SCREWS
OR CONSTRUCTION CEMENT.
PENDANT MOUNTING WITH
OPTIONAL CHAIN AND
'EYE' SCREW
5
OTHER MOUNT I NG OPTIONS:
OPTIONAL V-9805
VANDAL RESISTANT ENCLOSURE
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.