Valcom VIP-480AL-IC Quick Start Manual

Issue 1
VIP-480AL-IC IP One-Way Flexhorn
InformaCast® Compliant
SPECIFICATIONS
Access Methods
Singlewire InformaCast server  SIP-enabled telephone system
Features
RJ-45 for network connection  LED Status Indicator  Network activity LEDs  Power over Ethernet (PoE) 802.3af compatible
Dimensions/Weight
Horn
6.8” H x 8.3” W x 3.3” D
(17.3 cm) x (21.1 cm) x (8.4 cm)
Weight: 2.10 lbs. (0.95 kg)
Network Interface
1.62” H x 5.63” W x 3.45” D
(4.11 cm) x (14.30 cm) x (8.73 cm)
with brackets – 8.22” W (20.87 cm)  Weight: 2.10 lbs. (0.95 kg)
Nominal Power Requirements
Via 802.3af PoE Ethernet Switch: Class 3
Environment
Network Interface
Temperature: 0 to +40° C Humidity: 0 to 85% non-precipitating
Horn:
Suitable for indoor or outdoor installation
Packing List
Qty Item
1 Network Interface 1 VIP-480AL-IC Horn 1 VSP Document 1 VM-186 RJ-45 Connector
Precautionary Designations
CAUTION: To reduce the risk of electric shock,
Refer servicing to qualified service personnel.
CAUTION
DO NOT OPEN
Do not remove cover.
No user serviceable parts inside.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
FCC Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense.
Issue 1
1 947827
IMPORTANT SAFETY INFORMATION CONSIGNES DE SÉCURITÉ IMPORTANTES
1. Read these instructions. Lisez ces instructions.
2. Keep these instructions. Conservez ces instructions.
3. Heed all warnings. Respectez tous les avertissements.
4. Follow all instructions. Suivez toutes les instructions.
5. Do not use this apparatus near water. Ne pas utiliser cet appareil près de l'eau.
6. Clean only with dry cloth.
Nettoyer avec un chiffon sec.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Ne pas bloquer les ouvertures de ventilation. Installer formément aux instructions du
fabricant.
8. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat. Ne pas installer à proximité de sources de chaleur telles que radiateurs, registres de
chaleur, poêles ou autres appareils (y compris les amplificateurs) produisant de la chaleur.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade and the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet. Ne pas contourner le dispositif de sécurité de la fiche polarisée ou de mise à la terre. Une
fiche polarisée possède deux lames dont une plus large que l'autre. Une fiche de terre a deux lames et une troisième broche de mise à la terre. La lame large et la troisième broche sont fournies pour votre sécurité. Si la fiche fournie ne rentre pas dans votre prise, veuillez consulter un électricien pour le remplacement de la prise obsolète.
10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point where they exit from the apparatus.
11.Only use attachments/accessories specified by the manufacturer. N'utilisez que des fixations / accessoires spécifiés par le fabricant.
12. Use only with the cart, stand, tripod, bracket or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. Utilisez uniquement avec le chariot, stand, trépied, support ou table spécifié par le
fabricant ou vendu avec l'appareil. Quand un chariot est utilisé, Soyez prudent lorsque vous déplacez l'ensemble chariot / appareil pour éviter des blessures dues au renversement.
13. Unplug this apparatus during lightning storms or when unused for a long period of time. Débranchez cet appareil pendant les orages ou lorsqu'il n'est pas utilisé pendant une
longue période de temps.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way. Such as when the power supply cord or plug is damaged, liquid has been spilled, objects have fallen into the apparatus or the apparatus has been exposed to rain or moisture and does not operate normally or has been dropped.
Confiez toute réparation à un personnel qualifié. Une réparation est nécessaire lorsque l'appareil a été endommagé de quelque façon. Par exemple lorsque le cordon d'alimentation ou la fiche est endommagé, du liquide a été renversé, si des objets sont tombés dans l'appareil ou le appareil a été exposé à la pluie ou à l'humidité et ne fonctionne pas normalement ou s'il est tombé.
INSTALLATION
Mounting
The VIP-480AL-IC Network Interface is designed for wall or table mounting and must be within 100 meters of the network switch.
Wall: Using the wood screws and mounting brackets provided, secure the VIP-480AL-IC Network Interface to the wall.
Mounting (Horn)
Flush Mount using Mounting Screws
The cardboard packing material in which the horn is shipped also serves as the template for flush mounting. Using the template, mark the location of opening and mounting holes on wall. Drill holes appropriate to mounting hardware and cut out the opening. Make appropriate wiring connections and test the speaker for operation. Using appropriate mounting screws (not furnished) drill and mount the flange as shown.
UNIVERSAL BRACKET Loosen or separate the universal bracket leaves by loosening or removing the handle and hardware. Using the back leaf as a template, mark the wall through the mounting holes. Drill and mount to the wall using appropriate screws (not furnished) or mount directly to a junction box. Mount the T-bracket to the back of the horn as shown using the (2) ½ inch screws provided.
Power Connections
The only method of powering a VIP-480AL-IC Network Interface is via a Power over Ethernet (PoE) switch or power injector meeting the 802.3af specification. Make all required signal connections before connecting to Ethernet switch or power injector meeting the 802.3af specification.
Network Connection
The VIP-480AL-IC Network Interface has one RJ-45 network connector, and one RJ-45 horn connector. Use standard Ethernet patch cable to connect the NETWORK connector of the VIP-480AL-IC Network Interface to a PoE Ethernet switch.
Signal Connections
Audio output connection is made from the Signal Output. The RJ-45 connector on the horn is connected directly to the RJ-45 Signal Output socket on the IP Link. See Figure 1.
If additional length is required, any standard T568B extension may be used. See Figure 2.
Status Indicator Lights
The VIP-480AL-IC has 2 status indication lights located on network jack:
Green LED: (Link) Indicates Ethernet connection when illuminated.
Yellow LED: (Activity) Indicator flashes to indicate network activity.
Setup
The VIP-480AL-IC will automatically acquire an IP address (using DHCP) and connect to the InformaCast server when connected to the network and powered up. Information specific to your application will need to be programmed into the InformaCast server. Refer to the InformaCast documentation for further information.
2 947827
Loading...
+ 3 hidden pages