Table of Contents—2
Wall Mount Installation —3
Metal Double Mount Installation —4
Plastic Double Mount Installation —5
Plastic Double Mount Installation—6
Plastic Double Mount Installation—7
Wiring Information —8
Operational Instructions—9
Installation Option #1—10
Installation Option #2—10
Installation Option #2 Continued—11
Installation Option #3—12
Installation Option #4—12
Frequently Asked Questions—13
Troubleshooting—14
Overview - Diagnostic —15
Diagnostic #1—15
Diagnostic #2—16
Diagnostic #3—16
Diagnostic #4—17
FCC Wants You to Know—18
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019
540-563-2000 P. 540-362-9800 F. www.valcom.com
*manuals may change without prior notice
2
Wall Mount Installation
24 Volt/110 volt options shown in diagrams
12” Clock 16” Clock
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019
540-563-2000 P. 540-362-9800 F. www.valcom.com
1. Connect the wiring as shown on the wiring diagram (110V or 24V ONLY).
2. Mount both plastic anchors in the wall.
3. Insert the sheet metal screws (#10) through the mounting bracket into the plastic anchors.
4. Plug the connector into the movement (110V or 24V ONLY).
5. Hang the clock on the mounting bracket.
6. Put the screw (4mm) through the hole on the top of the clock into the hole at the top of the mounting bracket.
3
Metal Double Mount Installation
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019
540-563-2000 P. 540-362-9800 F. www.valcom.com
1. Screw the mounting bracket to the double gang box using four (4) inner holes on mounting bracket, or mount the mounting bracket directly to the wall or ceiling using the four (4) outer holes.
2. Insert the wires through the mounting bracket (110V or 24V ONLY).
3. Fish the wires through the clock hanging rod.
4. Secure hanging rod to mounting bracket with screws supplied, and place cover over connection.
5. Connect the wiring as shown on the wiring diagrams.
6. Plug the connectors into the movements (110V or 24V ONLY).
7. Place the clocks on the double mount housing and tighten the screws to secure clocks as shown above.
4
Plastic Double Mount Installation
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019
540-563-2000 P. 540-362-9800 F. www.valcom.com
y
e
y
r
Ethernet
Bracket
w
q
e
y
t
y
5
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019
540-563-2000 P. 540-362-9800 F. www.valcom.com
Plastic Double Mount Installation
*For metal mounting bracket: Use anchor that can support 50 lbs with a maximum screw size of 10/1.5”
Install metal mounting bracket - First, remove the metal mounting bracket from the inside of the double mount base by unscrewing
q
the two (2) 6-32 x 1/2” screws located on the underside of the base (save these screws for step #3). Next, screw the metal mounting
bracket to the wall or ceiling in which the clocks are being installed. To mount to the switch box, screw the four (4) 6-32 x 1” screws
supplied in the assembly kit through the inner four holes of the metal mounting bracket to the wall or ceiling. Use the outer four holes
to mount anchors to the wall or ceiling (both anchors and screws for anchors not supplied in kit). For IP clocks, if using an Ethernet
bracket (*as shown in the diagram) use the two (2) 6-32 x 1/4” included in the assembly kit to mount the Ethernet bracket to the metal
mounting bracket (Ethernet bracket not supplied in assembly kit).


w
Note: if the installer wishes to adjust the distance between the clock adaptor and the base of the double
mount, this can be accomplished by removing the adaptors from the double mount pole and choosing a
different hole on the double mount pole to route the wiring through before mounting to the wall.
e
Note: if using a plastic switch box, a ground wire must be routed through the switch box and into one (1) of
the four (4) metal mounting bracket screws in order to provide ground to the metal mounting bracket.
Note: the metal mounting bracket
anchors going into the wall.
Feed wiring through base and pole - Take the wiring coming from the switch box and begin to feed it through the center of the
base of the mounting assembly until it emerges from the hole in the center of the clock adaptor. Make sure there is roughly 1.5’ - 2’
of wiring coming from the switch box. Perform this task for both clocks. If installing IP clocks, run bare Ethernet wire without an RJ45
connector and install the connector after it has been routed through the clock if possible (this will be much easier than running the
wire with the connector on). If not possible, make sure that there is no boot present on the connector to run the wire through the
assembly. If you are using an Ethernet bracket with the installation of IP clocks, the assembly of the clocks in steps 4 through 6 can be
accomplished before mounting the assembly to the wall in step 3 - making the overall installation more simple.
Snap and screw base to metal mounting bracket - Snap the base to the metal mounting bracket by first making contact with the
lip in the upper side of the base and the metal mounting bracket. When the base has been snapped onto the bracket, take the two (2)
6-32 x 1/2” pan head screws that originally came installed on the base of the mounting assembly and screw them back into the two
holes on the underside of the base to secure the base to the metal mounting bracket.
MUST
be secured by both the screws going to the switch box
AND
the
Connect switch box wires to clock harness - Take the wiring harness supplied with the clock and make all necessary connections
r
between the wiring harness and the switch box wires using wire nuts. Perform this task for both clocks.
*instructions continued on next page
6
Loading...