Table of Contents
Table of Contents 2 Important Safety Instructions 3 Identify Your Clock 4 Wall Mount Installation - 5 - 8 Flag Mount Installation - 9 - 15 Double Mount Installation - 16 - 20 Wiring Information - 2-Wire Digital Communication 21
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
- 3-Wire Synchronous (Sync-Wire) Communication 24V 22
- 3-Wire Synchronous (Sync-Wire) Communication 110VAC 23 Frequently Asked Questions 24 Questions about Protocols 25 Troubleshooting 26 Diagnostic #1 - Protocol Verification 27 - 28 Diagnostic #2 - Comprehensive Test 29 - 30 Diagnostic #3 - Manufacturing Default 31 - 32 Warranty 32
Manuals may change without prior notice
2
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
Important Safety Instructions
VERY IMPORTANT:
KNOW YOUR COMMUNICATION PROTOCOL
The Valcom Wired clock is designed to support the 2-Wire Digital Communication Protocol as well as 3-wire (sync-wire) communication protocols. To run either system properly, the clock requires the correct wiring format. It is very important that you only follow the wiring instructions appropriate to your clock’s communication protocol. For example: if your system includes converter boxes which are only used for the 2-wire system, then you should only follow the instructions that relate to the 2-wire digital communication protocol wiring.
DANGER
! !
SHOCK HAZARD
,
• Keep the electricity to this device turned OFF until the clock installation is complete.
• Do not expose the clock movement to water, or install the clock in a location where it may be exposed to water.
H
|
NOTICE
• Do not install the clock outdoors. Damage to the clock if placed outdoors voids the warranty.
• Do not hang objects from the clock or clock mounting parts. The clocks are not designed to support the weight of other objects.
• The clock face and housing may be cleaned with a damp cloth or disinfectant. Test other cleaning products on a small part of the clock housing before attempting to use on the rest of the clock. Avoid bleach and chemicals known to dissolve plastics.
WARNING
FIRE HAZARD
• Always follow your national and regional electrical codes or ordinances.
• The AC power circuit for the clock must be attached to a circuit breaker that can be reset by the user.
PHYSICAL INJURY HAZARD
• If you are standing on an object while installing your clock, make sure that the object can support your weight, and will not sway or move as you stand on it.
• Take precautions to avoid injury by potential safety hazards near the point of installation including (but not limited to) heavy machinery, sharp objects, hot surfaces, or exposed cables carrying an electric current.
• Follow all mounting instructions exactly as stated in this manual. Failure to do so may result in the device falling off the point of installation.
• Packaging materials and mounting items include plastic bags and small pieces, which pose a suffocation hazard to young children.
3
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
Identify Your Clock
A label containing the part number of your clock is attached to the clock movement.
P. 540-563-2000 F. 540-362-9800 www.valcom.com
ORIGINAL CLOCKS
V-A2412
V-A2416 V-A11012 V-A11016
B-MODEL CLOCKS
V-A2412B V-A2416B
V-A11012B
V-A11016B
4
Wall Mount Installation
Included in Package
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
Description
Valcom analog clock
Mounting Bracket
12”: M- M B -12- 4
16”: M-MB-16 -2
Included in Wiring Kit (A-PK-12-2A)
Power/grounding wires and connector
#6 -32x1/ 2 screw
Quantity
1
1
1
2
Picture
M4 - 0.5x10
#10x1.5 Self-tapping screw
Wall anchor
Additional grounding wire
2
1
1
1
with connector
PLEASE NOTE: A user will also have to provide a Phillips-head screwdriver, a small slot-head screwdriver, a drill with a 1/4 inch drill bit, a pencil, a single gang box, any equipment needed to install the gang box, and any additional wiring needed to extend the signal, power, or ground cables.
If any of the items listed in the wiring kit are missing, you may contact Valcom and order a replacement kit.
5
Wall Mount Installation
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
1) Install the single gang box in the wall. Leave at least 17 inches between the bottom of the gang box and ceiling. Confirm that the bottom of the gang box is level with the floor.
1 2
17” Minimum
43.2 cm
2) Run power and communication wiring to the gang box. See the sections of this manual labeled “Wiring Information” for additional details, depending on your system.
If you are using a 2-wire system, pull the YELLOW and GREEN wires out of the connector.
CHECK YOUR WIRING
The voltage between the white and black wires should measure 105-126 volts AC in the 110 volt model or 21.5-26.5 21.5-26.5 volts DC in the 24 volt model.
If you are using the 24 volt model, make sure that the wiring leading to the clock is from a Valcom power supply or V-VCU.
3) Attach the communication, power, and grounding wires from your kit to the communication and power wires in the gang box. See the Wiring Guide included later in this manual for additional details.
3
4) Use the #6-32x1/2 screws to attach the mounting bracket to the gang box. The gang box should be at the bottom of the mounting piece.
4
6
Wall Mount Installation
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
5) Use the pencil to mark the location of the large, circular hole at the top of the mounting bracket. Once finished, remove the mounting piece and drill a hole at the location you just marked.
5
6) Insert the wall anchor into the hole, then reattach the mounting bracket. This time, also insert the #10x1.5 through the top of the mounting piece and into the wall anchor.
6
7) Remove the gearbox pin, then, if the case is made of metal, attach the grounding wire to the grounding tab below and to the right of the clock movement.
7
8) Attach the Power connector to the port on the clock movement.
3-Wire Sync 2-Wire Digital
8
Black
Green
White
Yell ow
3-Wire Sync 2-Wire Digital
Black
White
Yell ow
White
Green
Black
White
Black
7
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
Wall Mount Installation
9) Attach the clock to the mounting piece so that the hole at the top of the clock lines up with the hole at the top of the mounting piece, and the hole at the bottom of the clock lines up with the hole at the bottom of the mounting piece.
P. 540-563-2000 F. 540-362-9800 www.valcom.com
9
10) Use the two M4-0.5x10 screws to attach the clock to the mounting bracket. The screws should pass through the top and bottom holes on the clock, followed by the top and bottom holes of the mounting bracket.
10
8
Flag Mount Installation
Included in Package
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
Description
Valcom analog clock
Mounting Bracket
Included in Wiring Kit (A-PK-12-2A)
Power/grounding wires and connector
#6 -32x1/ 2 screw
M4 - 0.5x10
Quantity
1
1 (not used)
1
(not used)
2
2 (not used)
Picture
#8x1.5 Self-tapping screw
Wall anchor
Additional grounding wire with connector
If any of the items listed in the kits are missing, you may contact Valcom and order a replacement kit.
1 (not used)
1 (not used)
1
Continued on next page
9
Flag Mount Installation
Included in Adapter Kit (V-SMR12A) or (V-SMR16A)
Valcom, Inc. 5614 Hollins Road Roanoke, VA 24019 USA
P. 540-563-2000 F. 540-362-9800 www.valcom.com
Description
Round Clock Adapter
Internal-tooth washer
#8-32x7/16 screw
Included in Pole Kit
Dual-mount pole, including mounting plate
Quantity
1
4
4
1
Picture
#10-32x3/8 green screw
PLEASE NOTE: A user will also have to provide a Phillips-head screwdriver, a small slot-head screwdriver, a drill with a 1/4 inch drill bit, a pencil, a double gang box, Four wall anchors that can support 50 lbs and a maximum screw size of 10x1.5”, four #8 screws for the wall anchors, four #6-32x1 screws for attaching the mounting plate to the gang box, any equipment needed to install the gang box, and any additional wiring needed to extend the signal, power, or ground cables.
1
If any of the items listed in the kits are missing, you may contact Valcom and order a replacement kit.
10
Loading...
+ 23 hidden pages