Valcom v-9970 Service Manual

VSP-9970
Issue 5
V-9970
SINGLE ZONE ONE-WAY
STATION LEVEL PAGE CONTROL
The V -9970 is a Single Zone One-way Station Level Page Control designed to provide ring trip and page access circuitry for use on standard telephone lines (PABX, Centrex or C. O. line connections). These instructions contain the specifications and information necessary to install, operate and maintain the Single Zone One-way Station Level Page Control.
Regulatory Information
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
FCC Registration #: BAFUSA-21973-PA-N
Ringer Equivalence #: AC 0.6B/DC 0.1B
This equipment is to be installed only in restricted access areas (Such as dedicated equipment rooms or equipment closets) in accordance with Articles 110-16, 110-17 and 110-18 of the National Electrical Code, ANSI/NFPA 70.
SPECIFICATIONS
Features
Automatic Gain Control
Paging from standard phone lines
Suppression of unwanted sounds (Pops and
tones)
Page disconnect on tones or C.O. open loop
Feedback reduction
Power on LED
Page in progress LED
User contacts provided
-12VDC or -24VDC operation
Background music input
VOX silence disconnect, user selectable
Absolute timeout, user selectable
Connects to telephone line via standard RJ11C
jack
CMOS DSP power efficient green technology
(Uses only 1 Watt average @ 12 Volts when utilizing a VP-412A - 2 Watts during page)
FCC Part 68 Compliant
UL Listed
1 947941
Nominal Specifications
Technical
DC Voltage Input: -12VDC or -24VDC @ 165mA Fusing: 1/2 Amp resettable polyswitch
Voice Paging
Ringing Detection: 38 - 130 Volts AC Tip/Ring Input Level: -20dBm - 0dBm S/N Ratio: 55dBm Tip/Ring Tone Out: -6dBm (1.09Vp-p) Noise Rejection: 1.5Vp -p common mode tip/ring 60Hz Rejection: 2.0Vp-p common mode tip/ring Paging Voice Out: -10dBm (0.693Vp-p) Voice Response: 150 - 5000Hz Tip/Ring Impedance: 600 Ohms with loop current 20 - 80mA REN: 0.2A Silence Timeout: Adjustable from 1 - 31 seconds Absolute Timeout: Adjustable 4 - 124 seconds Dial Tone Disconnect Frequencies: 350/440, 440/480, 440/620, 480/620, 525/660Hz
Background Music Music Response: 20 - 20kHz Music Input Level: -23 - 0dBm (0.15 - 2.2Vp-p) S/N Ratio: 75dBm PS Rejection: 52dBm Music Out: -17dBm (0.311Vp-p) nominal (User adjustable) Music Adjustment: 0.1 - 1.1X
Environmental Dimensions: 8.25" H x 4.50" W x 2.35" D (20.96cm H x 11.43cm W x 5.97cm D) Weight: 1.5 lbs. (.68 kg) Operating Temperature: 0 to +50oC Storage Temperatur e: -40 to +85oC Cooling: Free Air Convection Humidity: 10 - 90% (Non-condensing) Shock: 10G
INSTALLATION
The V -9970 Page Control must be powered by a Class 2 Listed, -12VDC output transformer or by -24VDC NEC Class 2 power source.
When using this equipment, basic safety precautions should be followed to reduce the risk of fire, electric shock and injury to persons:
1. Never install telephone wiring during a
2. Never install telephone jacks in wet locations
3. Never touch uninsulated telephone wires or
4. Use caution when installing or modifying
Mounting/Connections
1. Remove the metal mounting plate from the
2. Open the V -9970 enclosure to allow access
3. Using a 1/8" blade screwdriver, connect Tip
4. Attach two wires from a music source output
DESIGN
The Valcom V -9970 is designed to provide paging access from a standard analog PABX station number, a C. O. line or analog Centrex line. The Page Control incorporates the latest technology Digital Signal Processor (DSP) to recognize and transfer speech only, thus eliminating unwanted noises such as pops and tones. A discriminating Automatic Gain Control (AGC) is provided to make quiet pages louder and loud pages quieter.
The Single Zone One-way Station Level Page Control provides a music input with volume control for background music and an additional 1 Amp internal relay output (This input closes during a page to provide user page notification if desired).
5. A 1 Amp internal relay input is supplied to
6. Plug the RJ11C jack from a single line phone
7. Connect 12V power supply (VP-412A) to
8. Set dip switches for desired options. (See
Note: Dip switches for user options should be set for desired functions prior to replacing the enclosure cover and plugging in the power supply.
9. Replace cover and plug in power supply.
OPERATION
lightning storm.
unless the jack is specifically designed for wet locations.
terminals unless the telephone line has been disconnected at the network.
telephone lines.
rear of the V -9970 enclosure. Using two #6 3/4" wood screws, mount the plate in a vacant space on the backboard with the telephone system common equipment. Both
mounting holes must be utilized to insure secure mounting of the unit.
to connections and option switches. Slide the rear of the unit (Contains the board) onto the mounting plate.
and Ring from the Valcom amplified speakers to PAGE OUT on the V -9970 screw terminals.
to the terminal screws labeled SIG MUSIC and COM IN. Volume is adjusted by rotating R13 clockwise.
provide user page notification. Attach two wires from the notification equipment to the V -9970 if this feature is to be used.
to connector J2 on the V -9970.
connector J1 (If using the 24V option, connect the power supply to the ter minals marked COM and 24V).
chart following for settings).
2
To make a page from a remote location, dial the phone number the page adapter is connected to and issue page. The background music will fade and the page will be heard through the amplified speakers. When the page ends, the music will resume.
Note: For most efficient operation, use Valcom VP-412A, 120VAC plug-in power supply.
TECHNICAL ASSISTANCE
When trouble is reported, verify the unit is properly connected and there are no broken connections leading to this unit. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM and a test set and be calling from the job site. Call (540)
767-1555 for Valcom 24-hour Faxback System or visit our website at http://www.valcom.com.
Valcom equipment is not field repairable and fuses are not user replaceable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person and the nature of the problem. Send the unit to:
Repair and Return Dept.
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
563-2000 and ask for Technical Support or call (540)
VALCOM LIMITED WARRANTY
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service
4. freight charges for the return of products to Valcom are prepaid;
5. all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (Major repairs will be
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
Headquarters: In Canada Valcom, Inc. CMX Corporation 5614 Hollins Road 35 Van Kirk Drive #11 and 12 Roanoke, VA 24019-5056 Brampton, Ontario L7A 1A5 Phone: (540) 563-2000 Phone: (905) 456-1072 FAX: (540) 362-9800 FAX: (905) 456-2269
charge plus parts and labor will be applied to units defaced or physically damaged);
subject to additional charges for parts and labor).
3
DIP SWITCH SETTINGS
SW OFF ON
1 Silence Timeout Enable, Default Absolute Timeout Enable 2 No Disconnect on Dial Tone Disconnect on Dial Tone*, Default
Silence Timeout or [Absolute Timeout] Silence Timeout or [Absolute Timeout] 3 Off, Default 16 [64] Seconds 4 Off, Default 8 [32] Seconds 5 Off 4 [16] Seconds, Default 6 Off, Default 2 [8] Seconds 7 Off, Default 1 [4] Seconds (Selected timing options will be added to determine total time) 8 Loop Detect Disable Loop Detect Enable, Default
Changes in dip switch settings will take effect when an idle unit first senses ringing.
* Frequencies of Disconnect Tones: 350 / 440Hz 440 / 480Hz 440 / 620Hz 480 / 620Hz 525 / 660Hz
DIP SWITCH TERMINOLOGY
The word "default" refers to the factory dip switch setting. Dip switches 2, 5 and 8 are set "ON" at the factory enabling silence timeout, dial tone disconnect and loop detect enable. The pager will "disconnect" after a page is made when the caller places the receiver on-hook thus dropping the current loop (Loop detect) OR by dial tone if the current loop detect is not passed through the telephone switching system (Dial tone disconnect) OR if silence is detected on the line for 4 seconds (Silence timeout).
Dip switch 1 OFF, "Silence Timeout Enable" means the Page Adapter will hang up when the caller does not speak for a period of time as selected by dip switches 3 through 7 (Dip switch 5 is default set to 4 seconds). Note the times can be added on the dip
TIMING OPTIONS
switch settings. If dip switches 3 through 7 are set to OFF for no timeout, dip switch 1 has no effect and the timeout option does not occur. Dip switch 1 is default set to "OFF".
Dip switch 1 ON, "Absolute Timeout Enable" means the Page Adapter will hang up after a period of time as set by dip switches 3 through 7 regardless of silence from the person paging.
Loop Detect is factory set to the default setting of ON or enable which causes the V -9970 to "hang-up" when loop current is no longer detected signifying that the caller has hung-up. Sometimes the local telephone switch internal to the building does not pass this signal and then it becomes necessary to utilize other disconnect options.
4
Dipswitches (shown with Default Settings)
(Refer to Chart for actual times)
VP-412A Power Supply
J1
12V IN
24V Option (If used)
COM 24V
ON
PAGE OUT
8 7 6 5 4 3 2 1OFF
- +
R13
COM SIG
MUSIC IN
SW1
USER
CONTACT
SW2
LED designates page in process
Power On LED
Music Volume
J2
Connection made via an RJ11C jack
Incoming Telephone Line or PABX Station
OR
-24VDC Power Supply
Up to 150 Valcom
+
Amplified Speakers
Line Level
Music
Source
FIGURE 1 - ONE ZONE CONNECTIONS
LOCATION OF SCREW TERMINALS,
OPTION SWITCHES AND MUSIC VOLUME CONTROL
5
24V Option (If used)
12V IN
COM 24V
PAGE OUT
COM SIG
- +
MUSIC IN
W-BL BL-W W-O O-W
V-2003A
SW2 Must be OFF
USER
CONTACT
FIGURE 2
CONNECTIONS TO A V-2003A FOR 3 ZONES
Connection made
J2
via an RJ11C jack
Incoming Telephone Line or PABX Station
OR
VP-412A Power Supply
-24VDC Power
Supply*
J1
+
* May be provided by V-2003A
24V Option
12V IN
(If used)
COM 24V
- +
PAGE OUT
COM SIG
MUSIC IN
USER
CONTACT
Connection made
J2
via an RJ11C jack
J1
Incoming Telephone Line or PABX Station
OR
VP-412A Power Supply
-24VDC Power Supply
+
*
* May be provided by V-2006A
W-BL BL-W W-BR O-W
V-2006A
SW6 Must be OFF
FIGURE 3
CONNECTIONS TO A V-2006A FOR 6 ZONES
6
Loading...