Valcom v-9945a Service Manual

VSP-V-9945A
Issue 7
V-9945A
SINGLE TONE/INTERRUPTED
WARBLE TONE LOUD HORN
INTRODUCTION
The V -9945A is a horn with built-in tone generator and amplifier used for loud signaling applications. These instructions provide identification, connection, installation, operation and maintenance information for the V -9945A, Single Tone/Interrupted Warble Tone Horn Ringer.
SPECIFICATIONS
Purpose
The V -9945A provides amplified electronic tones for signaling in large or noisy areas or outside.
Applications
Night ringing
C. O. audi ble ringing
Time clocks
Special purpose signaling
Features
Self-contained tone generator, amplifier, volume
control and horn speaker
Single tone or warble tone outputs
Power supply included
Activated by dry contact closure
Single tone will override warble tone
Warble tone interrupted 1 second on, 5 seconds
off
Single tone continuous for duration of closure
Weatherproof
Units may be multipled for simultaneous access
Capacity
The V -9945A has provisions for two inputs, either or both of which can be used in an application. If both inputs are activated simultaneously, the single tone will override the warble tone.
The V -9945A is a stand alone ringer horn activated by
a relay. If more than one ringer horn is required, contact Valcom Technical Support at (540) 563-2000 for design assistance.
Dimensions/Weight
6.50"H x 8.20"W x 10.40"D, plus mounting
(16.51cm H x 20.83cm W x 26.42cm D)
4.3 lbs. (1.95 kg)
Power Requirements
-21.5 to -26.0VDC "B" battery, 250mA nominal.
Environment
Temperature: -20 to +55 degrees C
Humidity: 0 to 95% non-precipitating
DESIGN
Access Requirements
The V -9945A requires a dry contact closure for activation of each tone (If both tones will be used, two closures are required). The closures may be in the form of night ringing relay contacts, time clock contacts, a standard normally open switch or equivalent.
bracket
1 947747
Equipment Requirements
A system using the V -9945A will consist of the following:
Access equipment (See Design Section)
-24VDC power supply (Included with horn)
INSTALLATION
General
These instructions cover only the installation procedure for the Valcom V -9945A. Please consult practices for other equipment if any other equipment is being used.
TELEPHONE SYSTEM
NIGHT RING
CONTACT CLOSURE
TIME CLOCK
CONTACT CLOSURE
RED GREEN BROWN WHITE BLACK
-24VDC
POWER SUPPLY
V-9945A
A "C" clamp is provided with the ringer to
Connection to an electrical backbox is
The V -9945A may be rotated or moved up and down to obtain the desired position by loosening the knob (See Figures 2 and 3) at the bottom of the unit approximately 1 turn. Make required adjustment and re-tighten knob.
Lead Designations
Black Ground (+)
provided. Knockout holes are provided for punch out should additional holes be desired.
allow mounting to a beam. Place the bolt through the hole in the bottom of the base to secure the "C" clamp to the beam. (See Figure 2).
accomplished by channeling wire through the ball of the base (See Figure 3) and making appropriate connections. The base has holes punched for a double-gang square box, but by punching out additional knockout holes, the base can be mounted to a single-gang or octagon box.
White -24VDC
FIGURE 1 - TYPICAL INSTALLATION
Precautions
All precautions have been taken at the factory to insure that the equipment functions properly. To insure proper operation and to prevent equipment damage, please observe the following:
Unplug the power supply before making any
connections to the unit.
Do not apply power to the uni t until all
connections have been double-checked.
Attaching Speaker to Base
NOTE: For ease of installation, the base can be attached to the speaker before or after the base is mounted.
Loosen position adjustment knob.
Insert the ball of the base into the socket of
the speaker.
Tighten the position adjustment knob.
Mounting
The V -9945A should be mounted 12 feet to 25 feet high in the area requiring signaling. The unit can be
Connections
Connections should be accomplished using twisted pair telephone wire. The power supply should be located within 500 feet of the horn.
Connect negative (-)(-24VDC) lead of the
For warble tone access, connect contact
For single tone access, connect contact
Connections for both single tone and warble tones may be made to the same speaker.
Red Warble tone access Green Common Brown Single tone access
power supply to the white lead; connect positive (+)(Gnd) lead of the power supply to the black lead.
closure between red and green.
closure between brown and green.
mounted to a wall, a beam or an electrical box.
Mount the base to a wall using the two holes 2