Valcom V-9904M, V-9915M Installation Instructions Manual

UL LISTED (UUMW) FLUSH MOUNTED
LOUDSPEAKER INSTALLATION INSTRUCTIONS
V-9904M-5 Bridge
Bend tabs down to
locate bridge in
Attach backbox to
bridge using 4 screws provided with V-9915M
Cut 5.25" round
hole in ceiling tile 4" Ceiling Grille
and Speaker
4" SPEAKERS
Issue 9
14.50" X 13.60"
23.75" X 1.00"
REGULATORY INFORMATION
Listed by Underwriters Laboratories, Inc.
Category UUMW. Material and construction
permits use where ceiling plenum is part
of the air handling system.
Compound knockout(s) provided for listed
type metallic fittings for 1/2" and 3/4" plenum
rated cable and plenum whip flex conduit.
V-9915M UL LISTED BACKBOX AND V-9904M BRIDGE
ceiling tile cutout
1 947914
2
V-9914M + V-9915M = V-9916M
INSTALLATION INSTRUCTIONS
V-9915M-5 Backbox
V-9914M-5 Bridge
Attach backbox to
bridge with 4 screws
provided with V-9915M
Cut 8.5" round
hole in ceiling tile
Bend tabs down to
locate bridge in
ceiling tile cutout
8" Ceiling Grille
and Speaker
(4 white screws
provided)
8 " SPEAKERS
14.50" x 13.60"
23.75" x 1.00"