Valcom V-5335100 Service Manual

PagePac
®
by
PAGEPAC PLUS ZONE EXPANSION UNIT
V-5335100
INTRODUCTION
SPECIFICATIONS (see Table 2)
FEATURES
• Provides same features as PP+ Controller
• Maximum of 3 Z.E.U.s per Controller
Power Requirements
• Power from the PP+ Controller through the interconnect cable
Dimensions/Weight
• 16.00”W x 1.75”H x 6.875”D (40.64cm x 4.45cm x 17.46cm)
• 3.0 lbs (1.35 kg)
Environment
• Temperature:0 to 40°C (32 to 104°F)
• Humidity: 5 to 95%
Locate in an area free of excess moisture, corro­sive gases, dust and chemicals.
Issue 1
2. Connect 8-pin Molex from Controller to first Z.E.U., and next Z.E.U’s, if used.
NOTE: Up to 3 Z.E.U.s can be used, providing up to 56 paging and/or control zones.
3. Set DIP switches on each Z.E.U .(s).
4. Set the Zone Option switches on the Controller and Z.E.U.(s).
NOTE: For each zone used, no matter what its function, this switch needs to be set to one of three settings for proper zone operation before applying power to the system.
The Controller has eight switches for zones 1-8. Each subsequent Z.E.U. has switches for zones 9-24, 25-40, 41-56.
INSTALLATION
MOUNTING
NOTE: When installing the Zone Expansion Unit,
leave at least four inches of space above and below for proper ventilation.
Installing the paging equipment in a ventilated room where there is easy access to speaker cabling (preferably in the tel ephone equipment room). Disconnect all power before installing equipment.
1. Mount the Zone Expansion Unit(s)(Z.E.U.) to either a wall, cabinet or a rack (below the con­troller).
Refer to the Zone Map and Zone Configuration Tables filled out during facility paging system design. You can find these in the PagePac® Sys­tem Installation and Configuration Guide.
5. Locate and mount all speakers in accordance with the floor plan drawing for this installation.
6. Connect each speaker to the appropriate Home Run or Speaker-to-Speaker wiring scheme as shown on the floor plan.
NOTE: Adjust all speakers p er volume and power requirements as noted on floor plan, during or after installation. Figures 7 and 8 show wiring methods using local and zone connector blocks, and contact closure zone applicat ions.
1947187
7. Test speaker wiring for short circuits. Measure the resistance of each Home Run wi ring with an ohmmeter. Any pair indicating a value of less than 15 Ohms must be rechecked for possi­ble shorted wiring or speakers. Correct any prob­lems and retest.
8. Make zone connections to Controller and Z.E.U. (see Figures 5 thru 7).
The zone connectors on the Contr oller and Z.E. U. can accommodate up to two 22 AWG wir es or four 24 AWG wires per zone output. Check zone option switch setting with Zone Map and Zone Configuration tables as you connect each zone. NOTE: DO NOT over tighten zone connector screws.
Powering Up System
With all zones wired and connected to the Con­troller and Z.E.U.(s), initial testing can begin. Once initial testing is done, you can begin to pro­gram the Controller with the features for each zone.
1. Plug the power cord into the AC input connec­tor on the AmpliCenter®. the following should happen: a. The green Power LED on the AmpliCenter
will turn on and stay on.
b. The green Page Access LED on the
AmpliCenter also turns on, but will go out after a few seconds.
c. On the Controller, verify that th e green
Phone System Enabled LED is off.
d. On the Controller, verify that the yellow
Attendant Access Enabled LED is off.
e. The green Power LED on the Z.E.U.( s) will
turn on and stay on. NOTE: If during power up, the system does not respond as described, refer to the Troubleshoot­ing section of this guide, and/or the PagePac® Plus System Installation and Configuration guide for detailed troublesh ooting.
TROUBLESHOOTING
Some common problems encountered when the paging system is not operating are described below. Check each item in the order listed.
1. No AC power to AmpliCenter or Controller (they supply power to the Z.E.U.(s)).
2. Host telephone system failure.
3. Host system page port failure.
4. A hardwire disconnect between host system and Controller.
5. AmpliCenter, Controller, or Z.E.U. zone switches or DIP switch settings tampered with .
If the problem has not been resolved by checking the preceding items, refer to the troubleshooting tables in the PagePac Plus Install ation and Con­figuration Guide.
Controls and Indicators, Terminals and Connectors
Figure 9 shows the controls and indicators, termi­nals and connectors on the rear panel of the Z.E.U.(s). Table 1 identifies them by function.
Table 1: Controls and Indicators, Terminals
and Connectors
1. Zone option 3-position slide switch: 70V audio out, contact closure input, contact closure output.
2. Zone connector for expansion zones: plus, minus, and ground screw terminals.
3. 8-pin Molex connector from controller: power, control, and audio or previous Z.E.U.
4. 8-pin Molex connector to additional Z.E.U.: power, control and audio.
2. Begin programming the Controller. A quick reference card for telephone program­ming, along with detailed programming instruc­tions, can be found in the PagePac Plus System Installation and Configuration Guide, Programming
.
5. DIP switch to be set when one, two, or three Z.E.U.(s) are used.
2947187
TECHNICAL ASSISTANCE
When calling, have a VOM and a telephone test set available and call from the job site. Call (540) 427-3900 and ask for PagePac Technical Sup­port, or call (540) 427-6000 for Valcom 24-hour Automated Support or visit our websites at http://www.pagepac.com and www. valcom.com.
Table 2. Z.E.U. Specifications
Capacities Each Z.E.U. connects up to 16 zones of audio out put (inc lu din g ta lk bac k ), cont act
closure outputs or inputs.
Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number , contact person, and the nature of the problem. Send the unit to:
PagePac
®
Repair Dept.
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Dimensions and Weights
Electrical Relay Contacts
Temperature Range: 0 to +40 deg. C (32 to 104 deg. F) operational
Humidity Range: 5 to 95% (non-condensing) storage/shipment and operation Altitude: Sea level to 10,000 ft. operational (1048 to 648 millibars) 40,000 ft. max. shipment Environmental Locate in an area free of excess moisture, corrosive gases, dust, and chemicals Interconnect Cable 8-position, 5 Amp contact rating, locking, keyed, 22 AWG wire, housing material
Height: 1.75” (4.4 cm) Width: 16” (40.64 cm); 19” (48.3 cm) with brackets attached Depth: 6.9” (17.53 cm) Weight: 3.0 lbs (1.35 kg)
Control Contact Closure: Contacts ar e rated at 120VAC/50VDC at 1 Amp Audio Zone: Contacts are rated at 2 Amps
-40 to +66 deg. C (-40 to +150 deg. F) storage and shipment
94V-2, prov iding 70 .0 Vrms (4), common ground, +17VDC, Serial Dat a and Clock D ata
Figure 1. Wall Mounted Hardware
3947187