Issue 5
V-2003A-E - THREE ZONE CONTROL UNIT
V-2003AHF-E - THREE ZONE TALKBACK CONTROL UNIT
INTRODUCTION
The V-2003A-E Three Zone control Unit provides telephone system access to multiple zones (up to 3) of one way paging plus all call.
The V-2003AHF-E Three Zone Talkback Control Unit provides telephone system access to multiple zones (up to 3) of handsfree talkback and/or one-way paging with a one-way all call.
"WARNING: To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture."
"WARNING: Shock Hazard - Do Not Open."
"AVIS: Risque de Choc Electrique ne pas Ouvrir."
"PELIGRO: Corriente Electrica - No Abra."
“CAUTION: To reduce the risk of fire replace only with same type 1A, 125V fuse. 1A, 125V may be replaced by a 0.5A, 250V provided voltage selector is set for 230V.”
“DANGER: Afin de réduire le risque de feu, remplacez le fusible par le même type de fusible à 1A, 125V. On peut utiliser un fusible à 0.5A, 250V pourvu que le sélecteur ďalimentation soit fixé sur 230V. Ne pas ouvrir.”
“VORSICHT: Zur verringerung von feuergefahr die sicherung nur mit derselben type 1A, 125V ersetzen. Statt 1A, 125V Kann 0.5A, 250V Benutzt werden, vorausgesetzt, die spannung ist auf 230V eingestellt. Nicht öffnen.”
“PELIGRO: Para reducir el peligro de incendio remplazarlo unicamente con un fusible del mismo tipo 1A, 125V. El fusible de 1A, 125V podra ser remplazado por uno de 0.5A, 250V si el selector de voltaje esta puesto en 230V. No abres.”
SPECIFICATIONS
Access Methods
Electronic Key System
PABX (Loop or Earth Call Trunk)
600 Ohm page port equipped with separate
contact closure and MF dialing capability
(NOTE: Page port must be -directional if talkback paging is desired)
Stand Alone Handset (used only for access of the V-2003A-E and V-2003AHF-E).
Features of the V-2003A-E
3 zones of one-way paging
One-way all call
Integrated power supply
Volume Controls supplied for
* Background music * Page * Warble tone/single tone
Dip switch programmable per zone (music
and tones)
Dial tone (optional)
(#) Button returns dial tone
Supplies 1 Amp at -24VDC for powering speaker
amplifier assemblies
Provides audio for up to 150 Valcom one-way
speaker amplifier assemblies per zone
230VAC at 50Hz or 115VAC at 60Hz operation
AC input fused at 0.5 Amp at 230VAC or 1 Amp
at 115VAC
Override capability
Inhibit circuitry (speaker cancel)
UL, CSA and VDE Listed
1 947205
Additional Features Supplied by the V-2003AHF-E
3 zones of handsfree talkback, one-way or mixed paging.
Dip switch programmable per zone (music, tones, and one-way or talkback).
Pre-announce tone (optional).
Repeated alert tone (optional).
Two volume controls for handsfree paging
* Page (phone to speaker)
* Receive (speaker to phone)
Supplies 0.5 Amp at 24VDC for powering one-way amplified speakers (a reduction of
0.5 Amps from the V-2003A-E).
Priority Sequence
The V-2003A-E and V-2003AHF-E are designed to allow a time clock signal to override an ongoing override page, override page to override system page, system page to override night ring or music and night ring to override music.
Physical Description
The V-2003A-E and V-2003AHF-E are contained in single, gray steel cases which can be wall or shelf-mounted.
V-2003A-E:
7.15" H x 10" W x 3" D (18.16cm H x 25.40cm W x 7.62cm D)
4.1 lbs. (1.86 kg)
V-2003AHF-E:
7.15" H x 10" W x 3" D (18.16cm H x 25.40cm W x 7.62cm D)
5.6 lbs. (2.54 kg)
Nominal Specifications
Input Impedance: 600 Ohms Input Level: -10dBm Music Source Impedance: 8 to 600 Ohms Music Input Level: -10 to -18dBm Output Impedance: 8 Ohm (1 way) 45 Ohm (talkback) Output Level: -10dBm (1 way) 1 Watt (talkback) DC Output: -24VDC at 1 Amp (V-2003A-E)
-24VDC at 0.5 Amp (V-2003AHF-E)
Nominal Power Requirements
Voltage: Current: 115VAC 1 Amp 230VAC 0.5 Amp
NOTE: The V-2003A-E/V-2003AHF-E is equipped with a standard 3-prong MOLEX connector to allow connection of a battery backup supply in case of AC power failure.
Use a cord set consisting of a minimum 18 AWG cord and grounding type attachment plug rated a minimum of 15A, 250V. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and marked HAR.
The socket outlet shall be installed near the equipment and shall be easily accessible.
Environment
Temperature: 0 to 40°C Humidity: 0 to 85% non-condensing
OPERATION
DO NOT OPERATE UNIT WITH COVER REMOVED!
Press the line key button (key system) or dial the appropriate loop or earth call trunk or page port access code (PABX) to access the control unit. Dial desired zone code: 1, 2, 3 or 5, 6, 7 for individual zones (1, 2 and 3 respectively); 4 or 8 for the all call. Ringback tone (if so optioned) will be heard in the telephone. Make announcement and hang up. Page automatically disconnects and background music (if programmed) returns. (Ringback tone, when optioned, provides an alert tone to the talkback zones on a V-2003AHF-E).
Background Music
Background music may be connected to the control unit. Background music will mute in the zone accessed for the duration of the page.
Warble and Single Tones
Warble tone is available over the P.A. system when a common audible contact closure or 90VAC ring voltage is supplied by the telephone system. A single tone is provided over the P.A. when the unit is activated by an additional contact closure.
The single tone and warble tone may be dip switch selected on a per zone basis. (One dip switch is supplied per zone for tones, so single tone and warble tone are both selected on or both selected off).
2
INSTALLATION
Precautionary Designations
Wiring Instructions for Loop or Earth Call Access
Plug 50 pin, female amphenol connector into J2 of
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electri c shock,
Refer servicing t o qualified service personnel.
Do not remove cover.
No user serviceable parts i nside.
the control unit and use a KRONE block for crossconnections (See Figure 2).
1. Make certain Battery Feed switch (SW2) is ON
(in the Down position, see Figure 3).
2. Ascertain SW1 is in proper position. SW1
should be in the UP position for loop start
This symbol indicates that dangerous voltage constitut ing a risk of electri c shock is present within this unit.
operation; SW1 should be in the DOWN position for earth call operation.
NOTE: When using an earth call trunk port, an
This symbol indicates that there are important operati ng and maintenance instructi ons in the literat ure accompanying this unit.
NOTE: The telephone system referred to in this manual is the customer premise equipment such as a key system or PABX. The V-2003A-E/ V-2003AHF-E cannot be connected directly to the public telephone network (a central office line). All connections must be made prior to plugging the unit to AC power.
Mounting
The V-2003A-E/V-2003AHF-E was designed for wall or table mounting. Secure the unit to wall studs or suitable brace away from heat sources or strong magnetic fields (motors, fans, power supplies, etc.) with control and terminal strip accessible. Four wood screws are included for mounting.
NOTE: All controls and terminations are accessed by removing the right side panel.
Switch Selectable Options
Loop or earth call access, are switch selectable on the V-2003A-E/V-2003AHF-E. SW1 selects the loop/ earth call option for system tip and ring. SW5 selects the loop/earth call option for override tip and ring. (See Figure 3 for location). A 12-position dip switch is provided for programming capabilities. Figure 3 indicates the function of each dip switch (i.e., the feature it activates).
NOTE: For one-way paging on a V-2003A-E, the dipswitch for the talkback feature on a one-way zone must be set to "Off" (no zone x talkback).
The V-2003A-E/V-2003AHF-E requires a power down reset in order to implement dipswitch changes. (Unplug AC power from the V-2003A-E/ V-2003AHF-E for a minimum of 30 seconds then reconnect to effect a dipswitch change).
earth strap must be used to connect GND of the unit to an appropriate telephone system GND (see Figure 2).
If a modular cord is used for Tip and Ring connections, connect (J1) RJ-11 A/Tip and B/Ring to the appropriate loop exchange port of the phone system.
For punch down block A/Tip and B/Ring connections, connect Tip of the telephone system or loop or earth call trunk to the Tip (W/BL) pin and Ring to the (BL/W) of the KRONE block.
Connection of One-Way Amplified Speakers
Using twisted pair telephone wire, connect:
Zone 1 Speaker A/Tip, B/Ring - R/BL, BL/R Zone 1 Speaker -24VDC - R/O Zone 1 Speaker GND - O/R Zone 2 Speaker A/Tip, B/Ring - R/G, G/R Zone 2 Speaker -24VDC - R/BR Zone 2 Speaker GND - BR/R Zone 3 Speaker A/Tip, B/Ring - R/S, S/R Zone 3 Speaker -24VDC - BK/BL Zone 3 Speaker GND - BL/BK
NOTE: The V-2003A-E provides external power of 1 Amp of -24VDC to operate amplified speaker assemblies. Additional power supplies are required if more than one Amp is needed.
Each speaker should be connected to only one power source.
3
Loading...
+ 5 hidden pages