The V-2003A-E Three Zone control Unit provides
telephone system access to multiple zones (up to 3)
of one way paging plus all call.
The V-2003AHF-E Three Zone Talkback Control Unit
provides telephone system access to multiple zones
(up to 3) of handsfree talkback and/or one-way
paging with a one-way all call.
"WARNING: To reduce the risk of fire or electric
shock, do not expose this equipment to rain or
moisture."
"WARNING: Shock Hazard - Do Not Open."
"AVIS: Risque de Choc Electrique ne pas
Ouvrir."
"PELIGRO: Corriente Electrica - No Abra."
“CAUTION: To reduce the risk of fire replace
only with same type 1A, 125V fuse. 1A, 125V
may be replaced by a 0.5A, 250V provided
voltage selector is set for 230V.”
“DANGER: Afin de réduire le risque de feu,
remplacez le fusible par le même type de fusible
à 1A, 125V. On peut utiliser un fusible à 0.5A,
250V pourvu que le sélecteur ďalimentation soit
fixé sur 230V. Ne pas ouvrir.”
“VORSICHT: Zur verringerung von feuergefahr
die sicherung nur mit derselben type 1A, 125V
ersetzen. Statt 1A, 125V Kann 0.5A, 250V
Benutzt werden, vorausgesetzt, die spannung ist
auf 230V eingestellt. Nicht öffnen.”
“PELIGRO: Para reducir el peligro de incendio
remplazarlo unicamente con un fusible del
mismo tipo 1A, 125V. El fusible de 1A, 125V
podra ser remplazado por uno de 0.5A, 250V si el
selector de voltaje esta puesto en 230V. No
abres.”
SPECIFICATIONS
Access Methods
• Electronic Key System
• PABX (Loop or Earth Call Trunk)
• 600 Ohm page port equipped with separate
contact closure and MF dialing capability
(NOTE: Page port must be -directional if
talkback paging is desired)
•Stand Alone Handset (used only for access of
the V-2003A-E and V-2003AHF-E).
Features of the V-2003A-E
• 3 zones of one-way paging
• One-way all call
• Integrated power supply
• Volume Controls supplied for
* Background music
* Page
* Warble tone/single tone
•Dip switch programmable per zone (music
and tones)
• Dial tone (optional)
• (#) Button returns dial tone
• Supplies 1 Amp at -24VDC for powering speaker
amplifier assemblies
•Provides audio for up to 150 Valcom one-way
speaker amplifier assemblies per zone
• 230VAC at 50Hz or 115VAC at 60Hz operation
• AC input fused at 0.5 Amp at 230VAC or 1 Amp
at 115VAC
• Override capability
• Inhibit circuitry (speaker cancel)
• UL, CSA and VDE Listed
1947205
Additional Features Supplied by the
V-2003AHF-E
•3 zones of handsfree talkback, one-way or
mixed paging.
•Dip switch programmable per zone (music,
tones, and one-way or talkback).
• Pre-announce tone (optional).
• Repeated alert tone (optional).
• Two volume controls for handsfree paging
* Page (phone to speaker)
* Receive (speaker to phone)
•Supplies 0.5 Amp at 24VDC for powering
one-way amplified speakers (a reduction of
0.5 Amps from the V-2003A-E).
Priority Sequence
The V-2003A-E and V-2003AHF-E are designed to
allow a time clock signal to override an ongoing
override page, override page to override system
page, system page to override night ring or music
and night ring to override music.
Physical Description
The V-2003A-E and V-2003AHF-E are contained in
single, gray steel cases which can be wall or
shelf-mounted.
•V-2003A-E:
7.15" H x 10" W x 3" D
(18.16cm H x 25.40cm W x 7.62cm D)
4.1 lbs. (1.86 kg)
•V-2003AHF-E:
7.15" H x 10" W x 3" D
(18.16cm H x 25.40cm W x 7.62cm D)
5.6 lbs. (2.54 kg)
Nominal Specifications
Input Impedance: 600 Ohms
Input Level: -10dBm
Music Source Impedance: 8 to 600 Ohms
Music Input Level: -10 to -18dBm
Output Impedance: 8 Ohm (1 way)
45 Ohm (talkback)
Output Level: -10dBm (1 way)
1 Watt (talkback)
DC Output: -24VDC at 1 Amp (V-2003A-E)
-24VDC at 0.5 Amp (V-2003AHF-E)
Nominal Power Requirements
Voltage: Current:
115VAC 1 Amp
230VAC 0.5 Amp
NOTE: The V-2003A-E/V-2003AHF-E is equipped
with a standard 3-prong MOLEX connector to
allow connection of a battery backup supply in
case of AC power failure.
•Use a cord set consisting of a minimum 18 AWG
cord and grounding type attachment plug rated a
minimum of 15A, 250V. The cord set should
have the appropriate safety approvals for the
country in which the equipment will be installed
and marked HAR.
•The socket outlet shall be installed near the
equipment and shall be easily accessible.
Environment
Temperature: 0 to 40°C
Humidity: 0 to 85% non-condensing
OPERATION
DO NOT OPERATE UNIT WITH COVER
REMOVED!
Press the line key button (key system) or dial the
appropriate loop or earth call trunk or page port
access code (PABX) to access the control unit.
Dial desired zone code: 1, 2, 3 or 5, 6, 7 for
individual zones (1, 2 and 3 respectively); 4 or 8 for
the all call. Ringback tone (if so optioned) will be
heard in the telephone. Make announcement and
hang up. Page automatically disconnects and
background music (if programmed) returns.
(Ringback tone, when optioned, provides an alert
tone to the talkback zones on a V-2003AHF-E).
Background Music
Background music may be connected to the control
unit. Background music will mute in the zone
accessed for the duration of the page.
Warble and Single Tones
Warble tone is available over the P.A. system when
a common audible contact closure or 90VAC ring
voltage is supplied by the telephone system.
A single tone is provided over the P.A. when the unit
is activated by an additional contact closure.
The single tone and warble tone may be dip switch
selected on a per zone basis. (One dip switch is
supplied per zone for tones, so single tone and
warble tone are both selected on or both selected
off).
2
INSTALLATION
Precautionary Designations
Wiring Instructions for Loop or
Earth Call Access
Plug 50 pin, female amphenol connector into J2 of
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electri c shock,
Refer servicing t o qualified service personnel.
Do not remove cover.
No user serviceable parts i nside.
the control unit and use a KRONE block for
crossconnections (See Figure 2).
1. Make certain Battery Feed switch (SW2) is ON
(in the Down position, see Figure 3).
2. Ascertain SW1 is in proper position. SW1
should be in the UP position for loop start
This symbol indicates that dangerous
voltage constitut ing a risk of electri c
shock is present within this unit.
operation; SW1 should be in the DOWN
position for earth call operation.
NOTE: When using an earth call trunk port, an
This symbol indicates that there are
important operati ng and maintenance
instructi ons in the literat ure accompanying
this unit.
NOTE: The telephone system referred to in this
manual is the customer premise equipment such
as a key system or PABX. The V-2003A-E/
V-2003AHF-E cannot be connected directly to the
public telephone network (a central office line).
All connections must be made prior to plugging
the unit to AC power.
Mounting
The V-2003A-E/V-2003AHF-E was designed for wall
or table mounting. Secure the unit to wall studs or
suitable brace away from heat sources or strong
magnetic fields (motors, fans, power supplies, etc.)
with control and terminal strip accessible. Four wood
screws are included for mounting.
NOTE: All controls and terminations are
accessed by removing the right side panel.
Switch Selectable Options
Loop or earth call access, are switch selectable on
the V-2003A-E/V-2003AHF-E. SW1 selects the
loop/ earth call option for system tip and ring. SW5
selects the loop/earth call option for override tip and
ring. (See Figure 3 for location). A 12-position dip
switch is provided for programming capabilities.
Figure 3 indicates the function of each dip switch
(i.e., the feature it activates).
NOTE: For one-way paging on a V-2003A-E, the
dipswitch for the talkback feature on a one-way
zone must be set to "Off" (no zone x talkback).
The V-2003A-E/V-2003AHF-E requires a power
down reset in order to implement dipswitch
changes. (Unplug AC power from the V-2003A-E/
V-2003AHF-E for a minimum of 30 seconds then
reconnect to effect a dipswitch change).
earth strap must be used to connect GND of the
unit to an appropriate telephone system GND
(see Figure 2).
If a modular cord is used for Tip and Ring
connections, connect (J1) RJ-11 A/Tip and B/Ring to
the appropriate loop exchange port of the phone
system.
For punch down block A/Tip and B/Ring connections,
connect Tip of the telephone system or loop or earth
call trunk to the Tip (W/BL) pin and Ring to the
(BL/W) of the KRONE block.
Connection of One-Way Amplified
Speakers
Using twisted pair telephone wire, connect:
Zone 1 Speaker A/Tip, B/Ring - R/BL, BL/R
Zone 1 Speaker -24VDC - R/O
Zone 1 Speaker GND - O/R
Zone 2 Speaker A/Tip, B/Ring - R/G, G/R
Zone 2 Speaker -24VDC - R/BR
Zone 2 Speaker GND - BR/R
Zone 3 Speaker A/Tip, B/Ring - R/S, S/R
Zone 3 Speaker -24VDC - BK/BL
Zone 3 Speaker GND - BL/BK
NOTE: The V-2003A-E provides external power
of 1 Amp of -24VDC to operate amplified speaker
assemblies. Additional power supplies are
required if more than one Amp is needed.
Each speaker should be connected to only one
power source.
3
Loading...