Valcom V-2001A Service Manual

Issue 8
V-2001A
SINGLE ZONE (PLUS) PAGE CONTROL UNIT
The V-2001A provides telephone system access to a single zone of one-way paging.
“WARNING: To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture.”
“WARNING: Shock Hazard - Do Not Open.”
“AVIS: Risque de Choc Electrique ne pas Ouvrir.”
“PELIGRO: Corriente Electrica - No Abra.”
“CAUTION: To reduce the risk of fire replace only with same type 1A, 125V fuse. 1A, 125V may be replaced by a 0.5A, 250V provided voltage selector is set for 230V.”
“DANGER: Afin de réduire le risque de feu, remplacez le fusible par le même type de fusible à 1A, 125V. On peut utiliser un fusible à 0.5A, 250V pourvu que le sélecteur ďalimentation soit fixé sur 230V. Ne pas ouvrir.”
“VORSICHT: Zur verringerung von feuergefahr die sicherung nur mit derselben type 1A, 125V ersetzen. Statt 1A, 125V Kann
0.5A, 250V Benutzt werden, vorausgesetzt, die spannung ist auf 230V eingestellt. Nicht öffnen.”
“PELIGRO: Para reducir el peligro de incendio remplazarlo unicamente con un fusible del mismo tipo 1A, 125V. El fusible de 1A, 125V podra ser remplazado por uno de 0.5A, 250V si el selector de voltaje esta puesto en 230V. No abres.”
SPECIFICATIONS
Access Methods
Electronic Key System (C. O. Line Position)
PABX (Loop Start Trunk Port)
1A2 Key Systems (400 type line card
required)
600 Ohm Page Port
Dedicated Single Line Telephone(s)
Features
Pre-Page Alert Tone
Page override capability (Using C. O. line
position or loop start trunk port)
Switchable battery feed for loop start operation
RJ-11 for Tip and Ring connections
AGC on all voice outputs
Provides audio for up to 150 Valcom
one-way amplified speaker assemblies
Background music input
Voice operated VOX to mute music during
page
Easily accessible music and tone volume controls
Removable screw terminal connectors provided
1 947202
Supplies 20 Valcom power units for powering Valcom one-way amplified speakers (1 Amp -24VDC); Additional power supplies are required for a quantity of speakers using over 20 power units
Page with music outputs (2 provided); music mutes during page
Page without music output
Battery backup input (Use Valcom VPB-260
battery backup supply)
Time clock/single tone (Contact closure activated)
Night ring/warble tone (Closure or 90VAC activated) Priority sequence of tones: Page overrides music Night ring mixes with music and page Time clock mixes with music and page
Individual switches for selection of night ring and time clock tones per output
May be used with 25 or 70 Volt amplifiers
AC powered, 115 or 230VAC
Internationally recognized power connector
AC input fused at 1 Amp @ 115VAC, 60Hz
or 0.5 Amp @ 230VAC, 50Hz
115/230 Volt selector switch for international use
UL listed
Dimensions/Weight
7.06"H x 9.00"W x 2.40"D
(17.93cm H x 22.86cm W x 6.10cm D)
Weight: 3.7 lbs. (1.68 kg)
Nominal Specifications
Input Impedance: 600 Ohms Input Level: -10dBm nominal Voice Switch Sensitivity: -21dBm Music Source Input Impedance: 8 to 600 Ohms Music Input Level: -10dBm nominal Output Impedance: 8 Ohms Output Level: -10dBm nominal DC Output: 1 Amp at -24VDC
Nominal Power Requirements
Voltage: Current: 115VAC 1.0 Amp
230VAC 0.5 Amp
Battery Backup
The V-2001A is equipped with a standard 3-prong polarized MOLEX connector to allow connection of a fused output (3 Amp) battery backup supply (Valcom VPB-260 or equivalent) in case of AC power failure. Backup time will be a function of system usage.
Use a cord set consisting of a minimum 18 AWG cord and grounding type attachment plug rated a minimum of 15A, 250V. The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and should be marked HAR.
The socket outlet shall be installed near the equipment and shall be easily accessible.
NOTE: The AC line cord of the VPB-260 and the AC line cord of the V-2001A should be plugged into the same AC circuit.
Environment
Temperature: 0 to +40° C Humidity: 0 to 85% non-precipitating
INSTALLATION
NOTE: The telephone system referred to in this manual is the customer premise equipment such as an electronic key system, a PABX or a dedicated single line telephone(s). The V-2001A is not intended for direct or indirect connection to the public telephone network or to PABX analog station ports. When used with a customer premise telephone system such as a key system or PABX system, these units are interfaced to the system via a fully protected page port or system central office port, which is a fully protected interface device. Also, the host system must be configured to disallow central office trunk conferencing in order to prevent indirect connection to the public network.
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electric shock,
Refer servicing to qualified service personnel.
Do not remove cover.
No user serviceable parts inside.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
2
Loading...
+ 4 hidden pages