Issue 1
V-1055
45 OHM TALKBACK CORNER SPEAKER
INTRODUCTION
The interior corner speaker, the V-1055 is a 8”
interior talkback speaker for use with Valcom
“Handsfree” talkback page control units. The
enclosure is made of steel with a durable powder
coated finish. The color of the enclosure can
easily be changed to match any decor. A cloth
covered detachable grille is included.
Mounting
Remove cloth covered grille from baffle. Place
speaker in the desired mounting location. Mark
“keyhole” slot for mounting (see figure 1). After
making the required connections, secure baffle to
wall with a suitable mounting screw (#10 sheet
metal screw or similar). Attach cloth covered
grille to baffle.
Connections
Two conductor twisted wire is required for the 45
Ohm talkback speakers. Standard 22 or 24
gauge station wire is acceptable. Shielded wire is
not required or recommended. Connections are
as follows:
• Speaker out from page control to speaker tip
• Speaker common to speaker ring
SYSTEM DESIGN
General
The 45 Ohm Talkback Speakers are designed to
be used with the Valcom "handsfree" talkback
control units. In combination with these units,
they will provide both loudspeaker and talkback
functions.
A standard Valcom talkback paging system is
made up of three basic components:
1. A talkback page control unit
2. Speakers (45 Ohm)
3. A power supply
Consult Valcom's VSP - Handsfree Talkback
Paging (Part # 947099) for detailed information on
selecting the control unit and power supply.
1 947675
Dimensions/Weight
• 10.00"H x 12.00”W x 4.50”D
(25.4cm H x 30.48cm W x 11.43cm D)
• 3.0 lbs (1.36 kg)
Environment
Temperature: -20 to +55oC
Humidity: 0 to 95% non-precipitating
Coverage
The distance you can be away from a speaker
and still have good talkback depends on the type
of speaker and the ambient noise level. In a
typical office environment, a wall speaker will
cover approximately 600 square feet when
mounted eight feet from the floor
TYPICAL REPLY DISTANCE CHART
Machine
Shop
(Noisy)
Shipping
(Moderate)
Waiting
Rooms
(Quiet)
90
Talkback not recommended above 80dB
80
70
60
50
10' 20' 30' 40' 50'
Maximum Talkback Reply Distance
FIGURE 1
NOTE:
The speaker is no better than your ears. If you
cannot carry on a conversation at normal
Voice levels over the required talkback distance,
then the talkback page equipment will not function
satisfactorily.
Use common sense when mounting a talkback
speaker. The speaker should be as close as
possible to the area where talkback is desired.
It should not be mounted close to or pointed at,
noise producing equipment such as fans, air
conditioners, machinery or compressors.
TROUBLESHOOTING CHART
SYMPTOMS ACTIONS
• No sound in page mode • Check tip and ring for audio at speaker.
• Check tip and ring for audio at control unit.
• Low sound in page mode • Check volume controls at page control.
• Poor listening in talkback
mode
Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of
one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective
device within the warranty period, provided that:
1. inspection by Valcom, Inc. indicates the validity of the claim;
2. the defect is not the result of damage, misuse or negligence after the original shipment;
3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (a service charge plus parts
and labor will be applied to units defaced or physically damaged);
4. freight charges for the return of products to Valcom are prepaid;
5. all units ‘out of warranty’ are subject to a service charge. The service charge will cover minor repairs (major repairs will be subject to
additional charges for parts and labor).
This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any
anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation
or use of the product.
This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be
notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point.
• Check talkback volume control at page control. Set control
where audio is clearly audible.
VALCOM LIMITED WARRANTY
Headquarters:
Valcom, Inc.
5614 Hollins Road
Roanoke, VA 24019-5056
Phone: (540) 563-2000
FAX: (540) 362-9800
TECHNICAL ASSISTANCE
When trouble is reported, verify there are no
broken connections. Troubleshooting assistance
is available from the factory. Call (540) 563-2000
and press 1 for Technical Support or visit our
website at http://www.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair and Return Dept.
5614 Hollins Road
Roanoke, VA 24019-5056
2