Issue 1
Issue 1
VIP-432-DF
IP TALKBACK FLUSH MOUNT SPEAKER/CLOCK ASSEMBLY
INTRODUCTION
The VIP-432-DF IP Talkback Speaker with Clock
enables handsfree talkback access and visual time
indication to a single location over an IP-based
LAN/WAN. This allows handsfree communication
anywhere on the network. The speaker level is
adjusted via software during set up. A call switch
input is provided for call initiation. Clock
synchronization is initiated via connection to any
Network Time Protocol (NTP) server accessible via
the network. The enclosure is made of steel with a
durable gray powder coated finish. The color of the
enclosure can easily be changed to match any
decor. A detachable black clothe grille is included.
Power is provided to the VIP-432-DF via a Power
over Ethernet (PoE) switch meeting the 802.3af
specification.
SPECIFICATIONS
Access Methods
PBX, FXO Port w/VIP-811
POTS telephone set w/VIP-811
PBX, FXS Port w/VIP-821
Valcom M Cast Page Group
SIP telephone system
Features
RJ-45 network connection
Power over Ethernet (PoE) 802.3af compatible
High Efficiency Class-D Amplifier
DIMENSIONS/WEIGHT
20.28” H x 14.38” W x 3.40” D
(51.51cm x 36.53cm W x 8.64cm D)
Weight: 4.25 LBS (1.91 kg)
Environment
Temperature: 0 to +40° C
Humidity: 0 to 85% non-precipitating
Packing List
Qty. Item
1 VIP-432-DF
1 VSP Document
INSTALLATION
FCC Information
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when
the equipment is operated in a commercial
environment. This equipment generates, uses
and can radiate radio frequency energy and if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference in which case
the user will be required to correct the
interference at his own expense.
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electric shock,
Refer se rv ic ing to q u alif ie d serv ice personne l.
Do not remove cover.
No user serviceable parts inside.
This symbol indicates that dangerous
voltage constituting a risk of electric
sho ck is pre s ent within th is unit.
This symb o l indica tes that there are
imp o rta nt op erating an d ma in tena nc e
instruc tio n s in the litera tu re accom pan yin g
this unit.
1 947794

Mounting
The VIP-432-DF is designed for flush mounting on
a hollow surface or to a Valcom backbox. Using the
dimensions shown in Figure 2 as a guide, cut a hole
in the mounting surface large enough to allow
recessing the VIP-432-DF into the wall. Next, drill
mounting holes in the surface to align with the four
mounting holes in the grille. Using appropriate
anchors and screws (not included), mount the
VIP-432-DF to the surface. Alternatively, Valcom
backbox model VB-R19 is available for mounting
this model.
Network Connection
The VIP-432-DF has one RJ-45 network connector
on the rear panel. Use the standard Ethernet
patch cable and connect the VIP-432-DF to an
Ethernet switch. (See Figure 1)
Call Switch Connection
The VIP-432-DF provides a call switch input via
screw terminal connections. (See Figure 1)
Mute Out Connection
The Mute Out may optionally be connected to the
mute input of Valcom Classroom audio
management systems in order to suspend locally
originated classroom audio during intercom
announcements.
LED Connection
LED (+) and (-) is a current limited output designed
to illuminate an optional LED. The LED is intended
to provide visual indication of call progress. The
LED illumination will flash when the call switch is
pressed and will continue to flash until the call is
answered. The LED illumination will be solid when
a connection to the unit is established.
-10 dB Line Level Out Connection
The -10dBm Line Level Out may be connected to
up to 40 Valcom Self Amplified Speakers in order to
provide additional sound reinforcement in an area.
Setup
Information specific to your application will need
to be programmed into the VIP-432-DF using a
computer. The PC used for programming should
be connected to the same subnet as the
VIP-432-DF. Setup will be done using the IP
Solutions Setup Tool. The IP Solutions Setup Tool
may be downloaded from the Valcom website at
www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being
supplied to the unit and there are no broken
connections. If a spare unit is available, substitute
a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the
factory. Call (540) 563-2000 and press 1 for
Technical Support or via email at
support@valcom.com
When requesting assistance, you should include all
available information. It is strongly suggested that
you go to the web site and review the information
available at http://www.valcom.com.
Valcom equipment is not field repairable. Valcom,
Inc. maintains service facilities in Roanoke, VA.
Should repairs be necessary, attach a tag to the
unit clearly stating your company name, address,
phone number, contact person and the nature of
the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
Figure 1. Connections
2