Valcom IP Solutions VIP-431-DS User Manual

Issue 1
Issue 2
VIP-431-DS
IP TALKBACK WALL SPEAKER/CLOCK ASSEMBLY
The VIP-431-DS IP Talkback Wall Speaker with Digital Clock enables two-way handsfree voice access to a single location over an IP-based network. This allows a page zone extension anywhere on the network. The speaker audio level is electronically adjusted via software. Clock synchronization is acquired from a Network Time Protocol (NTP) server, either a private internal server or from the Internet. A call switch input is provided for call initiation. The enclosure is made of steel with a durable gray powder coated finish and features an angled design to direct sound downward. The color of the enclosure can easily be changed to match any decor. A detachable black cloth grille is included. Power is provided to the VIP-431-DS via a Power over Ethernet (PoE) switch meeting the 802.3af specification.
SPECIFICATIONS
Access Methods
PBX, FXO Port using a VIP-811  POTS telephone set using a VIP-811  PBX, FXS Port using a VIP-821  Valcom M Cast Page Group  SIP–enabled telephone system
Features
RJ-45 network connection  802.3af compatible  High Efficiency Class-D Amplifier  Network Time Protocol (NTP) synchronization
INSTALLATION
FCC Information
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense.
DIMENSIONS/WEIGHT
15.0” H x 12.25” W
4.0” D (top) 1.45” D (bottom)
(38.1cm H x 31.1cm W
10.2cm D (top) 3.7cm (bottom)
Weight: 4.25 LBS (1.91 kg)
Environment
Temperature: 0 to +40° C Humidity: 0 to 85% non-precipitating
Precautionary Designations
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: To reduce the risk of electric shock, Refer se rvic ing to qu alifie d serv ice pers onn e l.
Do not remove cover.
No user serviceable parts inside.
This symbol indicates that dangerous voltage constituting a risk of electric sho ck is pre s ent within this un it.
This symb o l indica tes that there are imp o rtant op er ating a nd m a inte nance instruction s in the lit erature accompanyin g
this unit.
1 947793
NETWORK CONNECTION
Packing List
Qty. Item
1 VIP-431-DS 1 VSP Document
MOUNTING
Remove the screw holding the mounting bracket to the enclosure. Mount the bracket using appropriate hardware such as #8 pan head crews. After making the required connections, reattach the enclosure to the mounting bracket
SPEAKER CONNECTION DETAILS
LED (+) LED (-)
IP TALKBACK
CONNECTS TO SPEAKER OUT ON POWER FAIL
P6
P5P3P2P4
CALL SWITCH
SPEAKER OUT
NETWORK
-10 dB LINE LEVEL OUT
MOUNTING BRACKET
Figure 1. Connections
Network Connection
The VIP-431-DS has one RJ-45 network connector on the rear panel. Use a standard Ethernet patch cable to connect the VIP-431-DS to an Ethernet switch. (See Figure 1)
Call Switch Connection
The VIP-431-DS provides a call switch input via screw terminal connections. See Figure 1 for detailed connections.
LED (+) and (-) Connection
LED (+) and (-) is a current limited output designed to illuminate an optional LED. The LED is intended to provide visual indication of call progress. The LED illumination will flash when the call switch is pressed and will continue to flash until the call is answered. The LED illumination will be solid while a connection to the VIP-431-DS is established.
-10 dB Line Level Out Connection
The -10dBm Line Level Out may be connected to up to 40 Valcom Self Amplified Speakers in order to provide additional sound reinforcement in an area.
Setup
Information specific to your application will need to be programmed into the VIP-431-DS using a computer. The PC used for programming should be connected to the same subnet as the VIP-431-DS. Setup will be done using the IP Solutions Setup Tool. Download the latest version of the free IP Solutions Setup Tool from Valcom web site at www.valcom.com/vipsetuptool.
TECHNICAL ASSISTANCE
When trouble is reported, verify power is being supplied to the unit and there are no broken connections. If a spare unit is available, substitute a spare unit for the suspected defective unit.
Assistance in troubleshooting is available from the factory. Call (540) 563-2000 and press 1 for Technical Support or via email at support@valcom.com
When requesting assistance, you should include all available information. It is strongly suggested that you go to the web site and review the information provided at http://www.valcom.com.
Valcom equipment is not field repairable. Valcom, Inc. maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating your company name, address, phone number, contact person and the nature of the problem. Send the unit to:
Valcom, Inc.
Repair & Return Dept.
5614 Hollins Road
Roanoke, Va. 24019-5056
2 947793
Loading...