Vaillant VER 75/3, VER 100/3, VER 200/3, VER 150/3, VER 250/3 Installation And Operating Instructions Manual

Vaillant-Witte
®
Elektro-Raumheizer
Vaillant-Witte
®
Independent Room Heaters
VER 75/3, VER 100/3, VER 150/3, VER 200/3, VER 250/3
INSTALLATIONS- UND BEDIENUNGSANLEITUNG INSTALLATION AND OPERATING INSTRUCTIONS
Typ Art.-No. Connected load Voltage
[kW] [V] VER 75/3 6205 0,75 VER 100/3 6206 1,00 1/N/ VER 150/3 6207 1,50 PE~ VER 200/3 6208 2,00 230 VER 250/3 6209 2,50
8
Contents
page 1 Application 8 2 Construction 9 3 Installation 10 4 Electrical connection 11 5 Starting up 11
Technical data 12
Tabelle 1.1 Typenübersicht
Please read carefully through all the information given in this manual. It provides important instruction for the installation and maintenance of the appliance.
After installing the heater,please hand these instructions as well as the opera­ting instruction to the user for safe keeping.
Installation and initial start-up only by a qualified contractor.
Guarantee will only be valid if the appliance has been installed and started up initially by an approved contractor, who is responsible for the observance of applicable standards and installation instructions. We do not accept responsability for damage arising from the non-observance of these instruction.
1 Application
Universal independant room heaters, wallvanvectorsVER75/3-VER250/3, are designed and manufactured for a wide range of applications: residenti­al and business premises, bathrooms, halls, landings etc.
The VER 100 - 250/3applianceshave a splash-prof enclosure.
V-W 139/0
Fig. 2.1 Construction VER 75/3
Legend to fig. 2.1
1 Air outlet grille 2 Thermostat 3 Switch 4 1 m connecting lead up to
75/3 ... VER 200/3 with Euro-standard elbow plug
5 Air inlet grille
9
2 Construction
(Fig. 2.1, page 8) The housing which accommodates the
special-purpose heating unit is provi­ded with air slots underneath and at the front. The air is heated by free convection without a fan.
The cold air enters the appliance on the underside, is heated as it flows past the special heating element and leaves the heater through the air outlet grille.
At the rear, the convector is fitted with a thermostat on which the temperature can be infinitely selected with a dial.
Please note
The room heater must not be installed underneath a wall socket outlet.
The room heater must not be permanently wired to the mains.
The appliance must be installed in the bathroom in such a way that switches, regulating and control elements cannot be touched by a person using the bath or the shower.
Important! The housing temperature exceeds 60 °C. There is a danger of fire. See warning notice on the appliance.
Never cover the heater; not even for a short time!
There is a danger of fire. See warning notice on the appliance.
Never mount the appliance directly next to a curtain, screens or similar (see fig. 2.2).
V-W 108/0
Fig. 2.2 Wall mounting
V-W 142/0 X
Fig. 3.1 Appliance bracket
6 bracket 7 fixing clips 8 hooking tab
A =
>
10 cm
B =
>
10 cm
C =
>
75 cm
D =
>
20 cm
Appliance a b c d e type
VER 75/3 340 84 430 289 > 200 VER 100/3 420 164 430 289 > 200 VER 150/3 580 324 430 289 > 200 VER 200/3 740 484 430 289 > 200 VER 250/3 900 564 430 289 > 200
Distance from wall with appliance bracket 20 mm
10
V-W 106/1
Fig. 3.2 Fixing
V-W 143/0
Fig. 3.3 Mounting
6 bracket 7 fixing clips 8 hooking tab
If the heater is left off for a lengthy period or when cleaning it, switch it off with the switch (3, fig. 2.1, page 8) on the side.
After the installation the line connection has to be accessible.
The installation and electrical connection of the heater must be carried out by an approved skilled person.
3 Installation
Wall mounting
The heater must be mounted vertically (see fig. 2.1, page 8).
Fix the appliance bracket to the wall as shown in the installation sketch (fig. 3.1 and 3.2), using the enclosed installation materials. See fig. 3.1 on page 9 for installation measurements.
It is essential to maintain the minimum distance of 20 cm from the floor to the lower fixing hole.
Hook the heater into the lower fixing hooks.
Insert the upper fixing clips(7, fig.3.3) in their positions and press in.
7 fixing clips
Tabelle 3.1 Distance
11
V-W 141/0
Fig. 5.1 Starting up
V-W 140/0
Fig. 5.2 Thermostat setting
4 Electrical connection
The appliance must be connected to a 230 V~ supply via the mains plug. (For the VER 100/3 - VER 200/3).
A PE conductor is not present, since the appliance is of the totally insulated type.
The regulations of the local electricity board must be observed.
The appliance must be installed so that it can be disconnected from the supply before any intervention (e. g. pulling out the mains plug for VER 75/3 - VER 200/3).
The connecting lead is specific to con­vectors.
Changing the connecting lead must only be carried out by an approved contractor.
Only use original Vaillant special­purpose cables.
5 Starting up
Set the switch (3) to position „I”. The built-in room thermostat keeps the
required room temperature constant. If a room which is not being used is to
be protected against frost, set the ther­mostat knob (2) to position (❄).
5.1 Switch (3)
The heater is switched off when the O marking is visible. Involuntary control is therefore impossible.
The frost protection safeguard is also switched off at this setting.
5.2 Thermostat setting
Pull the two slides off the room ther­mostat (fig. 5.1).
Fit the slides at both sides of the stop according to the temperature/ temperature range.
Position ❄approx. 4 °C. Position 7 approx. 20 °C.
Legend to fig. 5.1 and 5.2
2 Thermostat 3 Switch 9 Slide
10 Case
t Temperature setting range
Technische Daten
Für Schäden, die durch Nichtbeach­tung dieser Anleitung entstehen, über­nehmen wir keine Haftung.
Technical data
We do not accept responsability for damage arising through the non­observance of these installation instruction.
8300 97 INT05 · 09/2000 V · Änderungen vorbehalten · Subject to alteration · Printed in Germany · Imprimé en Allemagne · Gedruckt auf 100 % Altpapier · Printed on 100% recycled paper
Vaillant GmbH
Berghauser Straße 40 .D-42850 Remscheid
Telefon (0 21 91) 18-0 .Telefax (0 21 91) 18-28 10
http://www.vaillant.de .E-Mail: info@vaillant.de
Typ VER75/3 VER100/3 VER150/3 VER200/3 VER250/3 Art.-Nr. 6205 6206 6207 6208 6209
Anschlußwert 0,75 kW 1,00 kW 1,50 kW 2,00 kW 2,50 kW connected load
Spannung 1/N/PE ~ 230 V Voltage
Frostschutz ca. 4 °C frost protection
Abmessungen: Dimensions: Höhe - height 430 mm 430 mm 430 mm 430 mm 430 mm Breite - width 340 mm 420 mm 580 mm 740 mm 900 mm Tiefe - depth 85 mm 85 mm 85 mm 85 mm 85 mm
Wandabstand 20 mm dist. from wall
Anschlußkabel 1 m Anschlußkabel 1 m
mit Euro-Winkelstecker Anschluß-
kabel Length of 1 m supply connection connection lead via mains plug lead
Gewicht 3,2 kg 3,8 kg 4,9 kg 6,3 kg 7,3 kg weight
Schutzart Spritzwasserschutz IP 24, Schutzklasse II
entspricht der Niederspannungs- und EMV-Richtlinie
type of enclose IP 24
Stand der Tabellenangaben: Juli 1995. Weiterentwicklung vorbehalten. Data in this valid July 1995. Subject to chance in the course of further development.