Vaillant VCW GB 221 H, VCW GB 240 X H, VCW GB 280 X H Instructions For Use Manual

Dear
Customer!
All
you
need
know about your
Valliant
Combi
is
conta.inedin
these
instructions, so that you will find:
the
left hand
column,
a series
Of
illustrations demonstrating step by step the whole procedure. ·
Introduction
/r1
the
centre column a// necessary
information
which
explains
the11/ustrated
procedure.
hand
column,
additional
information which may prove useful for
servicing and
handling;
Please
note that your Valliant
COMB!
Compact boiler must
be
installed by a competent person
{L
e.
CORGI
registered),
in
accmdance
with
the
current issue of the
Gas
Safety (Installation
and
Use}
regulations 1994,
as
amended.
Your
boiler requires air
for
combustion
and
to
ensure
safe
and
efficient operation
of
the flue.
Do
not obstruct
any
purpose provided ventilation openings to the outt;ide
air.
This appliance must be earthed.
If the appliance is installed
in
a compartment do not obstruct
any
purpose provided ventilation openings;
and
do notuseJor storage
purposes.
If
a
gas
leak
or
fault exists.
or
is
suspected, turn off the appliance
and
consult your local Gas Region or Service
Engineer.
As
the
colours
of
tile wires
in
the
n1ains
lead of tills appliance
may
not correspond with the
colowred
markings identifying tile terminals
in
your plug, proceed
as
Follows:
The
wire
whic!1
is
coloured must
be
connec::ted
to the terminal
in
the plug which is marked with the letter E or by
the earth symbol
@ or coloured green-and-yellow.
e
The
wire
which
is
coloured blue must be connected
to
the terminal which is marked with the letter N or coloured black:
• The wire which
is
coloured brown mustbe connected to
tl1e
terminal which
is
ma.rl<edwith the letter
Lor
coloured
red.
The following minimum clearances around the appliance case must
be
maintained.
80
mm
(3.2") either side. The side clearance may bereduced to 25
mm
{1
")from removeable fittings such
as
kitchen untis.
150
rnm
(6") below
100
mm
(4") above
2
[PREPARATION·-·FOR
STA:.:;...::R_;;_;:TJ:.::...::N..=.G
___
_
Check
of
supply pipes
Ensure
cold water shut-off valve@
and
both the flow
and
return service ®
and @ are
open.
Also
checl<
that the gas
service
(J)
is
open.
Turn
QOid
water
shut off
valve
anticlockwise to
open.
Check of
water
contents
Open the lower door by pulling outwards.
Check the water contents of the system. The
white hand of the pressure gauge Q)
should
be
within the
green
band (about
1
to.
1.5
bar).
If the
hand
is
on
or below the
mark
(about
0.8
bai')
when
the system
is
cold,
then
your·
installer should
be
called
to refill the system.
{The
pressure
may
increase
when
the appliance
is
in
Normally the
flow.
return and gas service
cocks are
open,
and the line marking
wilr
have
the
same
direction
as
the pipe.
Topping up
should only be carried out by a
servlqe engineer or your
installer.
3
..
_______
-·-
--_-_-_-_
..
-_
..
·-·-_··
_
....
-_
....
____
__,
4
To
light
the
pilot
Op!';n both doors
to
the appliance.
Press
the push
button®
hold
it
down. Light the
pilot
by
operaJing
the
pieZo ignitor@)
several
times.
· Checkthaf
the
pilot
is
alight
by
looking
through the viewing
window®.
After pilot ignition, keep
the
push
button®
depressed
for
about
10 seconds.
If the pilot does
not
light,llold
®
depressed for a longer period to allow any
airto
escapefrom
t!1e
pilot line and operate
tM
piezo igniter several times.lft!wpi!ot
flame goes
outwhen
button®
is released,
WAIT
AT
LEAST
3 MINUTES
before repeating the
pilot
lighting
proce-
duns.
DOMESTIC
HOT
1\....:..::T....:..::IO:=:...:N:...::__
________
_
----···-··-----··········--·····
.......................
1
Switch
on
main
switch
Ensutelleating switch@
and.
main
switch
@are off (position
0}.
Turn
the elecficity supply
on.
Pusl1
main switch@ into position L (main
switch lights up).
Attention
The main switch should only
be
operated
if
'-as
described under "Check water
con-
tents"
on
r:>age3-the appliahce is correctly
filled with water. Otherwise the heating pump
may
be damaged.
To obtain
hot
water
Onopening hot water tap@
at
a supply
point
(basin,
shower,
sink)
the Combi
will
light after
an
initial short
delay.
Witli the tap
fully open, should receive the maxi-
mum flow rate
of
hot water.
With
the tap
only approx. hajfopen, a lower flow rate
may
be
achieved
..
By
mixing
in
cold water
you
can
adjust tq any required lower
temperature.
On
closing
the
tap the
appliance automatically
cuts
out.
or
changes
to
heating,
if
set to do
so,
After
opening
U1e
upper door by pulling out-
wards, tile operation of the burner can
be
seen
through
vlowing
window
Q_p.
At this stage your Vaillant Combi
is
ready
to
supply hot water.
Wl1en
the
main switch lights
llp,
the app-
liance
can
be opetated.
If
the
hot water flow rate appears reduced,
check
- cold
water shut-off
valve
is
completely
open.
-
arty
valve.s
fitted between tap
and
appliance
are
open.
-
spout
outlet
is
n()t blocked.
Note: Boiler will not light at very
low flow
rates.
Tile· supply
of
hot water takes precedence
over the heating system, yet has
no
distur-
bing effect
on
tile steady heating of your
rooms for normal periods of use.
5
I TEMPERATURE SELECTOR · I
6
Set the domestic
l1ot
water
temppraturo
selector
.f.9
a$
follows:
The
domestic hot water temperature
can
be
increased by reducing the. water flow
rate
from
the
appliance.
Turn
the.
knob anti-
clockwise.
Tt1e
domestic hot water temperature
can
be reduced
by
increasing the
water
flow
rate
from
the.appliance.
Turn
the knob
ClockWise;
I HEATING-OPERATION
Set
the
flow
thermostat
The flow thermostat
knob®
adjusts
the
operating temperature.oi
the
boiler for
central heating.
Turn the
knob:·
Clockwise to Increase boiler temperature,
the
maximum setting
is
Anti-Clockwise to Decrease boiler
temperature, the minimum setting is
1.
For optimum control of your lwating
system
the
follo;,ving settings are
recommended:
Setting room temperature
Set the
room
thermostat.@
or
thermostatic
radiator
valve®
according
to
the
instruc-
tions supplied with the controL
..
·--1
Spring and Autumn Winter
EltoT
8to9
The
room
thermostat or thermostatic
radiator valves
:Will
provide more accurate
and economic room temperature control than
jqst
the
boiler thern1ostat.
7
[ HEATING OPERATION
-··--···-
..
·-
8
Switching
on
the
heating
switch
Push
the
heating switch@ to
I.
The
central
heating
system
will then start if beat is
required.
The
system
\Nill
now operate
automatically
and controls the
room temperature according to the temperature selected
on
the
bdilerthermostat or
external controls.
The
flow thermometer® indicates
the
temperature of
the
water
in
the central
heating circuit,
NOT
of
domestic hot water.
On
this setting your
Vaillant
Oombi
will
also
provide domestic
hot
water.
Note:
in
the
summer
time,
when
central heating
is
rioti"equired,
push
heating to
position 0
(OFF).
·
On
turning the room thermostat or boiler
thermostat to
a higher setting, the boiler
may
not fire immediately.
This
is
due
to the
integral
"anti-cycling" device
in
the boiler
preventing rapid
on
and
off operation of
the boiler.
[SHUTTING • CARE AND FROST PROTECTION
Note:
If outdoor temperatures
are
low,
the high
efficiency of the
f1ppliance
(energy
saving)
may
lead tovapourformation
on
the ex-
ternal terminal of the
flue duct. This
is
a
normal
physical phenomenon!
Care ami Maintenance
Clean
the outer casing
of
the boiler with a
damp
qloth
and a littlE?
soap.
Do
not use
any
abrasive or solvent
cleoming
rnateriaf
which could damage the casing or plastic
fittings. ·
To
turn
off
the
boiler
To
turn
off
the
central heating and
hot
water
for
short
periods
of
time
push the
rnain
switch
@to
position '0',
To
turn
off
the
the
central
heating
only
switch off by pushing the h0ating switch
@to
positiqn '0'.
(No1maf
position during summertime!)
To
turn
oft
central
heating
and
hot
water
for
longer periods
of
time
push
the
main
switGh@ to position
'0'
and
also
press
!he
push button
@to
shut
off
the pilot.
To
ensure
continued efficient operation of
the
appliance,
it
is recommended that
it
is
checked
and
serviced
as
necessary
at
re-
gular intervals.
The
frequency of servicing
will
depend upon the particular installation
conditions
and
usage,
l:)ut
in
ger!eral
once
per
year should
be
adequate. !tis the law
that
all
servicing work
is
carried out
by
a
competent person such as British Gas
or
other Corgi registered
persona!.
Refer
to.
the
label
on
the appliance
"Advice;
Service,
Repairs"
for
details
of
who
to contact
Frost
Protection
Please
ensure
that, if
you
are
absent during
a period offrost, the central
heating
system
Should
you
leave
for
alongertime
(i.e.
?ummer holidays)
you
shpuld
<;tlso
close
the cold watersl1ut·off valve@, isolate the electrical supply
and
turn
off the
gas
swpply.
The
pressure relief
valve
@is provided for
safety
reasons
and must
not
be
Interfered
with.
remains
ln
operatioi)
aM
the roorns are
kept
above
freezing
point.
It
must
then
be
remembered,
however,
that
the
appliance will
be
automatically swit-
ched off
by
the monitoring devices
lfcertain
faults
occur,
e.g.
interruption
!n
tht:l
energy
supply
(gas,
oil,
electricity)
or
tau
its
in
the
flue
gas
system.
Alternatively,
you
can
drain
both the
central
heating
system
and
the
E\ppli<;ince.
We
do not recommend the addition ofanti·
freeze
to
the
system
water,
This
could
lead
deterlot'ation of
seals
and diaphragms
as
well
as to
noisy
operation,
forwhfch-
lncluqing
any
consequentil;l.l
damage-
we
cannot accept
any
i·esponsibility.
9
I
FUEL
SPILLAGE SENS9Rtonlytorvcwg_B240,200}q
--·-·
-------
These
Vaillant open flued central heating
boilers are
fitted
with
a.
flue spillage
sensor.
In
the event thatflue.gasesare not
properly drawn into the flue system the flue spillage $ensor
will
automatically
shut
down the appliance,
If the
bOiler
shuts down for
any
reason,
operation will
be
prevented for between
15
and
20
minutes. After 20 minutes it will
be
possible to use the appliance
in
accordance with the instruCtions for
use.
IMPORTANT
In
case
of a repetive boiler cut-off,
disconnect the
main
switch
and
charge a
qualified fitter with the appliance check.
If
the
appliance repeatedly shuts down
do
not
use
It
and
consult your qualified
installer or service
engineer.
10
I OPERATING SUMMARY
---·-···
CD
Pressure gauge
® Flow thermometer
@ Pressure relief
valve
@ Heating return service
® Piezo lgnifer
® Cold water shut off
valve
(j)
Gas
service cock
® Heating flow service
cock
® Flow thermostat
@ Push button
to
light
the
pilot
0 Push button
to
shut-off the pilot
@ Heating switch
@ Main switch
@ Viewing window
(behind
the appliance upper door)
@ Room thermostat
@ Water outlet
(fj
Hotwatertap
@ Thermostatic. radiator
valve
Of
fitted)
We
do
not accept any liability for damage
arising as a result
of
the non-observance
of
these operating instructions.
i1
..........
£Q
C)
......
.....
N N
(")
Q:)
I
HEATING,
CONTROLS,
HOT
WATER
Head
Office
Voillaotltd.,
Vaillant
House,
MedwayCi!y
Estate,
Trident
Close,
Ro<:hester,
KentME2 4 EZ
Soles
Service
Solution&
Technical
Advice
Training
01634292310 0870 6060 777 01634 292392