Vaillant turboMAX plus, thermoCOMPACT Instructions For Use Manual

GB
Instructions for use
turboMAX plus, thermoCOMPACT
Instructions for use turboMAX plus, thermoCOMPACT2
Table of contents
Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specified use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
EC designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . 3
3 Factory Guarantee . . . . . . . . . . . . . . . . . . . . . . . 3
4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Initial checks before turning ON . . . . . . . . . . . . . . . . . 5
Heating operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Resetting the appliance . . . . . . . . . . . . . . . . . . . . . . . . 7
Turning the boiler OFF . . . . . . . . . . . . . . . . . . . . . . . . . 8
Care and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . 9
Frost protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Status display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1 General
Thank you for choosing a Vaillant boiler. The information given in this booklet will enable you to obtain the best performance from your boiler.
turboMAX plus provides both central heating and domestic hot water, with the domestic hot water supplied directly from the boiler. The boiler will operate automatically to provide domestic hot water whenever a hot water tap is opened, and automatically adjusts to meet the demand for both central heating and domestic hot water in the most economical way.
thermoCOMPACT provides central heating and domestic hot water where a separate indirect hot water cylinder is also incorparated to the system. The turboMAX/ thermoCOMPACT range of boilers have a SEDBUK band 'D' rating.
If, after reading these instructions, you have any questions on the operation of the boiler, please contact either your installer or Vaillant Technical Department.
Key to symbols
Important Note
This symbol is used to indicate important instructions.
• This symbol is used to indicate a required step.
Liability
We can accept no liability whatsoever for damage or injury resulting from failure to obser­ve these instructions.
Specified use
Vaillant turboMAX plus and thermoCOMPACT boilers are made to fulfil the latest technical specifications and offi­cial safety regulations. These appliances are designed as boilers for use in central heating and hot water supply systems. thermoCOMPACT boilers only supply domestic hot water where a separate indirect hot water cylinder is also incorparated to the system. If the appliances are used for purposes other than or in excess of these speci­fications, this shall be classed as incorrect operation, and neither the manufacturer nor supplier will accept any liability for resulting damage or injury. Use of this type is entirely at the owner’s risk. The term „specified use” also covers observance of the operating and installation instructions, along with adherence to the servicing schedules.
EC designation
The purpose of EC designation is to certify that the boiler complies with the requirements of the directives covering gasfired appliances (Council directive 90/396/EEC) and electromagnetic compatibility (Council directive 89/336/EEC). These appliances also comply with the requirements of the directive on operating efficiency (Council directive 92/42/EEC).
Note! Vaillant Ltd. support the Benchmark initiative. In the installation manual you will find the Benchmark gas boiler commissioning checklist. It is very important that this is completed correctly at the time of installation and com­missioning.
Table of contents 1 General information
Instructions for use turboMAX plus, thermoCOMPACT 3
Safety instructions 2
Factory guarantee 3
2 Safety instructions
Setup and adjustments
Installation and adjustment of the boiler as well as service maintenance and repair of the boiler may only be carried out by a competent person in accordance with the Gas Safety (Installation and Use) Regulations
1998. (In the U.K. „CORGI“ Registered installers under­take the work to a safe and satisfactory standard). If the boiler is installed in a compartment do not obstruct any purpose provided ventilation openings, and do not use the compartment for storage purposes.
Gas smell
If you smell gas or suspect a gas leak:
- Turn off the boiler
- Do not switch any electrical switches in the hazardous area on or off
- Do not smoke in the hazardous area
- Turn off the gas supply at the gas meter
- Ventilate the room
- Consult your gas supplier, service agent or other com­petent person.
Modifications in and around the boiler
No modifications may be made to the following items:
- The boiler
- The gas, water and electrical supply
- The flue system
- The safety valve for the heating water
- Any structural changes around the appliance that could affect the operational safety of the boiler.
Explosive and flammable materials
Do not use or store any explosive or highly flammable materials (e.g. gasoline, paper or paint) near to the appliance.
Inspection
The boiler should be serviced annually. We recommend that you sign a service agreement with your service agent or Vaillant Ltd.
Attention! The device may only be used
• for initial operation
• for testing
• for continuous operation with the chamber cover closed and with the flue system fully mounted and sealed.
3 Factory guarantee
Vaillant provide a full parts and labour warranty for this appliance.
The appliance must be installed by a suitably competent person in accordance with the Gas Safety (Installation and Use) Regulations 1998, and the manufacturer’s instructions. In the UK ‘CORGI’ registered installers undertake the work in compliance with safe and satisfac­tory standards. All unvented domestic hot water cylinders must be installed by a competent person to the prevailing buil­ding regulations at the time of installation. (G3)
Terms and conditions apply to the warranty, details of which can be found on the warranty registration card included with this appliance.
Failure to install and commission this appliance in com­pliance with the manufacturer’s instructions may invali­date the warranty (this does not affect the customer’s statutory rights).
Immediate help
If your Vaillant boiler develops a fault your first action should be to contact your installer, as his professional assessment is needed under the terms of our Guarantee. If you are unable to contact your installer, phone Vaillant Service Solutions: 0870 6060 777.
Vaillant is a member of the Benchmark initiative and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of instal­lation and commissioning of central heating systems in the UK and to encourage the regular servicing of all cen­tral heating systems to ensure safety and efficiency.
4
4 Operation
Instructions for use turboMAX plus, thermoCOMPACT
4 Operation
Overview turboMAX plus
Fig. B.1a: Operating elements turboMAX plus
Operating controls
For access to the controls press the upper middle of the lower front panel and drop it down. The following can be seen: 1 Maximum radiator temperature control 2 The „+“ and „-“ buttons for the display panel 3 Main ON/OFF control 4 Built in control/timer module (if fitted) 5 The „i“ information button 6 Boiler display 7 Indicator lights to display the current operating mode 8 „Reset“ button 9 Maximum hot water temperature control and warm-
start ON/OFF control
10 Pressure gauge displaying the pressure in the heating
system
thermoCOMPACT
Fig. B.1b: Operating elements thermoCOMPACT
You can identify a thermoCOMPACT boiler by the sticker which is situated at the top left hand side of the control panel (see A, Fig. 1.b)
Operating controls
For access to the controls press the upper middle of the lower front panel and drop it down. The following can be seen: 1 Maximum radiator temperature control 2 The „+“ and „-“ buttons for the display panel 3 Main ON/OFF control 4 Built in control/timer module (if fitted) 5 The „i“ information button 6 Boiler display 7 Indicator lights to display the current operating mode 8 „Reset“ button 9 Pressure gauge displaying the pressure in the heating
system
Indicator lights/boiler display
turboMAX plus and thermoCOMPACT boilers have an advanced multifunction boiler display (1). When the main ON/OFF control is in the „ON“ position the display will normally show the temperature of water in the boiler circuit (45 °C in the example), which confirms that the boiler is functioning correctly.
Fig. B.2: LED displays
1 In the unlikely event of a fault developing which
prevents the boiler from operating, the display may show a fault code.
2 Red indicator
Illuminated = Boiler has locked out
3 Yellow indicator
Illuminated = Main burner ignited