Troubleshooting 5
0020277253_00 ecoFIT sustain Operating instructions 9
5. Turn the filling cock on slowly and allow water to flow in
until the required filling pressure has been reached.
6. Close the heating water supply.
7. Purge all radiators.
8. Check the filling pressure in the display.
9. Top up with more water if necessary.
10. Close the filling cock.
11. Return to the basic display. (→ Page 7)
4.12 Protecting the heating installation against
frost
4.12.1 Frost protection function
Caution.
Risk of material damage due to frost.
The frost protection function cannot guarantee flow through the entire heating installation, which means that parts of the heating
installation may freeze and therefore become
damaged.
▶ During a period of frost, ensure that the
heating installation remains in operation
and that all rooms are sufficiently heated,
even when you are away.
Note
To keep the frost protection devices active, you
should switch your product on and off using the
controller, if one is provided.
If the heating flow temperature falls below 5 °C when the
on/off button is on, the product comes into operation and
heats the circulating water to approx. 30 °C on both the heating side and the hot water side (if available).
4.12.2 Draining the heating installation
When the unit is switched off for an extended period, frost
protection can be guaranteed by completely draining the
heating installation and the product.
▶ Consult a competent person about this.
4.13 Switching the product to standby mode
▶ Press the reset button for less than three seconds.
◁ The display shows OFF and goes out.
◁ The product is now in standby mode.
◁ The product's frost protection function is activated.
◁ The main power supply is not interrupted. The
product continues to be supplied with power.
5 Troubleshooting
5.1 Detecting and rectifying faults
▶ If faults occur, proceed in accordance with the table in
the appendix.
Troubleshooting (→ Page 11)
▶ If the fault cannot be eliminated using the specified
measures or if fault messages (F.xx) occur, contact a
competent person.
5.2 Calling up (Live monitor) status codes
▶
Press and at the same time.
Status codes – Overview
◁ The current operating mode (status code) is shown
on the display.
6 Care and maintenance
6.1 Maintenance
An annual inspection of the product carried out by a competent person is a prerequisite for ensuring that the product is
permanently ready and safe for operation, reliable, and has a
long working life.
6.2 Caring for the product
▶ Clean the casing with a damp cloth and a little solvent-
free soap.
▶ Do not use sprays, scouring agents, detergents, solvents
or cleaning agents that contain chlorine.
6.3 Reading maintenance messages
If the symbol is shown in the display, the product requires
maintenance work.
The product is not in fault mode but continues to operate.
▶ Consult a competent person about this.
▶ If the water pressure is flashing at the same time, simply
add more heating water.
6.4 Checking the condensate discharge pipe
and tundish
The condensate discharge pipe and tundish must always be
penetrable.
▶ Regularly check the condensate discharge pipe and tun-
dish for faults and, particularly, for blockages.
You must not be able to see or feel any obstructions in the
condensate discharge pipe and tundish.
▶ If you notice a fault, have it eliminated by a competent
person.