rctic White Version
Part Number 999-6947-000AW (North America)
Part Number 999-6947-001AW (International)
EZIM CCU Slot Card for HD-19
W
™
™
C
C
C
U
H
U
H
C
Quick-Connect CCU Interface for HD-19
D--1199
D
WallVIEW CCU HD-19
Inside Front Cover - Blank
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 2 of 20
WallVIEW CCU HD-19
p
WallVIEW CCU HD-19 Overview:
The WallVIEW CCU HD-19 HD camera, Quick-Connect CCU and
EZCamera™ Cat-5e cabling system using HSDS™, delivers a
system that allows for easy installation and integration. The HD-19
camera is built around a 1/3-type Exmor high-speed CMOS image
sensor with a total of 1.3 Megapixels and a 19X optical zoom lens,
making it the ideal choice for a wide range of HD video applications.
Because the camera module is built around a new, high speed
CMOS image sensor with an increased pixel aperture size, high
frame rate, high signal to noise ratio, using the column-parallel A/D
conversion method, the resolution, saturation and the sensitivity of
the sensor is increased. The HD-19 achieves improved picture
quality even in low light environments requiring a minimum
illumination rated at an astonishing 0.7 LUX (F1.6 - 50IRE).
The HD-19 is paired with the Quick-Connect CCU Interface and EZIM CCU Slot Card, which provides power,
video and control to the camera up to 500’ (152.4m) over three (3) Cat-5e cables. The Quick-Connect CCU
functions allow users to control a variety of image controls built into the camera, including iris, red and blue gain,
pedestal, knee, chroma, SmartShot™ and overall gain. The CCU also has three (3) preset scenes available for
time of day or other interesting lighting conditions.
The WallVIEW CCU HD-19 is an exceptional camera system for integration projects, since no power supply is
required at the camera location. Use the WallVIEW CCU HD-19 for high definition camera applications, such as
houses of worship, corporate boardrooms, live event production and distance-learning.
Intended Use:
Before operating the device, please read the entire manual thoroughly. The system was designed, built and
tested for use indoors, and with the provided power supply and cabling. The use of a power supply other than the
one provided or outdoor operation has not been tested and could damage the device and/or create a potentially
unsafe operating condition.
Important Safeguards:
Read and understand all instructions before using. Do not operate any device if it has been dropped or damaged.
In this case, a Vaddio technician must examine the product before operating. To reduce the risk of electric shock,
do not immerse in water or other liquids and avoid extremely humid conditions.
Use only the power supply provided with the system. Use of any
unauthorized power supply will void any and all warranties.
Save These Instructions:
The information contained in this manual will help you install and operate your product. If these instructions are
misplaced, Vaddio keeps copies of Specifications, Installation and User Guides and most pertinent product
drawings for the Vaddio product line on the Vaddio website. These documents can be downloaded from
www.vaddio.com free of charge.
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 3 of 20
Please do not use “pass-thru” type RJ-45 connectors. These pass-thru type connectors do not
work well for professional installations and can be the cause of intermitten t connections which
can result in the RS-232 control line failing and locking up, and/ or compromising the HSDS™
signals. For best results please use standard RJ-45 connectors and test all cables for proper
in-outs prior to use and connection to Vaddio product.
WallVIEW CCU HD-19
UNPACKING:
Carefully remove the device and all of the parts from the packaging.
Unpack and identify the following parts for 999-6947-000:
One (1) ClearVIEW HD-19 HD Camera
One (1) Vaddio IR Remote Commander
One (1) Quick-Connect CCU Interface
One (1) EZIM CCU Slot Card
One (1) 36 VDC, 2.78A Power Rite™ Switching Power Supply
One (1) 998-1001-232 EZCamera Control Adapter (for control systems)
One (1) Thin Profile Wall Mount with Mounting Hardware
One (1) AC Cord Set for North America
Documentation
(Note: The 999-6947-001 Int’l Version includes the Euro and UK power cables)
ClearVIEW HD-19 PTZ Camera, Front View with Feature Call-outs:
①
④
②
③
1) Zoom Lens and Image Sensor:
The 19X optical zoom lens is built around a 1/3-Type, high-speed, progressive scan CMOS image sensor with a
total of 1.3 Megapixels for precise HD video image acquisition.
2) Red Tally Light:
A red tally light is illuminated when the camera receives a VISCA command from an external control system.
3) IR Sensors:
IR sensors are built into the front of the ClearVIEW HD-19 to receive IR signals from the IR remote control
supplied with the camera.
4) Blue Power Light:
A Vaddio blue power light is illuminated when the camera is turned on.
Compatible Switchers and Joystick Controllers:
ProductionVIEW™ HD MV
(999-5625-000)
AutoPresenter
(999-5675-000)
Precision Camera Controller
(999-5700-000)
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 4 of 20
WallVIEW CCU HD-19
ClearVIEW HD-19 PTZ Camera, Rear View with Feature Call-outs:
⑤
⑨
⑥
⑩
⑦
⑪
⑧
5) RS-232 IN & IR Out:
The RS-232 accepts modified VISCA protocol for camera control, as well as transmits IR signaling received by
the IR receivers, which can be transmitted to third party devices.
6) Dip Switch Settings:
Settings for IR remote, baud rate, SD output format, and image flip can be configured on these switches. See
page 5 for additional information on switch settings.
7) HD Video Select:
A rotary switch allows the user to choose the component HD output video resolution and format. See page 6 for
additional information on switch settings.
8) 12 VDC Input:
Power input for the standard, ClearVIEW HD-19 camera power supply.
9) YPbPr Output:
Component HD video is fed through the DB-15 connector. YPbPr and Composite signals are simultaneous. This
is an HD camera and the SD signals are down converted and are really not the sweet spot of this camera.
9) Composite Video (CVBS) Output:
The CVBS output feeds out SD video signals and is configurable with the dip switches to choose between
480i/NTSC or 576i/PAL in 4:3 formats. Squeeze and letterbox modes are also available (see dipswitches 6&7).
11) EZ Power/Video Port:
This RJ-45 connector is only used with the Quick-Connect SR Interface and the Quick- Connect DVI-D/HDMI SR
Interface to supply power and return HSDS video from the camera.
12) Slot for Optional Cards:
Optional slot cards can be plugged into the ClearVIEW HD-19 camera (the HD-SDI and the EZIM CCU Slot Cards
are available).
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 5 of 20
⑫
WallVIEW CCU HD-19
Quick-Connect CCU for HD-19, Front Panel Controls (left to right):
Tally Light:
The blue LED tally light on the front panel is tied to the tally contacts on the rear panel allowing the user to easily
track which camera interface is being used in a multi-camera system by supplying a simple contact closure.
LCD Display:
Backlit (blue) display indicates which parameter (iris, detail, etc.) is being adjusted. When a rotary encoder is
moved, the name of the control being adjusted and the value of that assigned parameter will be displayed.
Quick-Connect CCU Controls (left to right - magnified):
Scenes A, B & C:
Three camera adjustment scenes (A, B & C) can be stored into microprocessor memory. When lit (backlit blue
SPDT Button), the scene is activated. To store a scene, the user adjusts the controls and touches and holds the
scene button down until the button blinks.
Detail: The Detail control sharpens or softens objects in the frame. This control works well to sharpen text.
Red & Blue Gain Controls: The Red and Blue Gain encoders adjust the red and blue gain of the signal when
AWB is disengaged.
AWB: The Automatic White Balance controls/adjusts the color levels automatically when engaged. Turn off
AWB to manually adjust the Red and Blue levels, as well as Red, Green and Blue Enhance.
OPWB: One Push White Balance is not operable in this release
Gamma, Chroma and Brightness Control:
Gamma adjusts the overall brightness of an image. Chroma controls the color of the image being acquired
without affecting brightness. The brightness control governs the overall brightness of the image.
SHIFT: Pressing Shift illuminates the button and changes the Gamma, Chroma and Brightness Control to Digital
Image Stabilization, Shutter Control and Noise reduction. Digital Image stabilization works well if the camera is
hand-held or the surface where the camera is mounted has vibration (front of a church balcony). NOTE: When
using a joystick for control of the camera, leave image stabilization off because the subsampled window if the
video image will cause delay and is not going to allow an operator to be very precise with the cam era movement
and joystick. Shutter adjustments are 1/30 to 1/500. For most applications 1/60 will work fine. Noise Reduction
can be on or off and will help reduce the noise produced by sub optimum conditions.
Auto Iris: The Auto Iris mode automatically adjusts the iris and gain of the camera. To manually adjust the iris or
gain, turn off this control. With auto Iris engage, the SmartShot (AGC Gain Limit) can be set to off, low, med, and
high. SmartShot limits the ACG Gain to avoid poor image reproduction in suspect lighting conditions).
Manual Iris: The Manual Iris control allows the user to set the iris manual to one of the settings available.
Gain: The Gain control boosts the signal level when the iris is open all the way, and there is not enough lighting
available. To manually adjust the Gain, Auto Iris must be off.
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 6 of 20
WallVIEW CCU HD-19
Quick Connect CCU Rear Panel Connections and Controls (left to right)
Power Supply Input:
36V 2.78 Amp power supply on a 5.5mm OD x 2.5mm ID connector.
Power on RJ-45:
Power is provided on a Cat-5e cable to the EZIM CCU Slot Card. Power is on all 4-pr and is connected to the
36VDC RJ-45 on the EZIM CCU Slot Card.
①
RS-232 IN on RJ-45:
RS-232 IN from ProductionVIEW or PTZ controller RS-232 port. Daisy Chain control is not supported.
RS-232 OUT / G/L Out on RJ-45:
The RS-232 OUT is connected to the HD-19 RS-232 RJ-45 jack. The HD-19 camera does not support
GENLOCK.
Tally on 2-pin Phoenix type connector:
Contact Closure lights a Vaddio blue LED on front panel allowing indication of which CCU/camera combination is
active in a multi-camera/CCU installation. A tally command will also be sent to the HD-19 camera to illuminate
the red LED on the camera’s base.
G/L Input on BNC-F:
This option is not used with the HD-19 camera.
Camera Feature Switches:
The Quick-Connect CCU has an 8-position dip switch on the rear panel. For the HD-19, all these switches should
be set to the down position.
Y-Gain:
Adjusts Y-Gain and allows the user to fine tune the video signal especially over longer cable lengths. Adjust to
system requirements (100 IRE on waveform analyzer).
Distance:
Distance adjustments for Cat-5e cable (<100’, 200’, 300’, 400’+) which, equalizes the length of the twisted pairs
for improved video performance.
Four video signals can be transmitted from the EZIM CCU concurrently allowing the CCU system to return HD
and SD (composite video on cameras with simultaneous outputs, such as the HD-19) at the same time. Note: YC (S-Video is not available on the HD-19 camera).
Connector Labels and Supported Video Signals
Y/Y: Y of YPbPr on BNC-F connector
PB/C: PB of YPbPr on BNC-F connector
PR: PR of YPbPr on BNC-F connector
COMP: Composite (CVBS) Video on BNC-F connector
Video RJ-45
This jack is connected to the HD-19 EZIM CCU Slot Card Video RJ-45 Jack to return HD video to the CCU.
②
EZIM CCU Slot Card
①②
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 7 of 20
WallVIEW CCU HD-19
First Time Set-up with the HD-19:
The ClearVIEW HD-19 was designed to be exceptionally easy to use and operate. There is documentation at the
back of the manual for pin-outs for all of the connectors on the ClearVIEW HD-19 camera.
Step 1: Using the HD Video Select Rotary Switch and Camera Settings Dip Switch on the back of the camera,
set up the camera’s output resolution and functional preferences. There is a label on the bottom of the camera
that identifies the choices.
HD Video Select Switch Camera Settings 10-Pos Dip Switch
HD-19
Rear
Panel
Label on the Bottom of HD-19
IR 1
1 & 2 UP
IR 2ONIR 3
ON
21
1234
DIP SWITCH SETTINGS
IR
OUT
OFF
ON
3
9600
bps
38400
bps
4
SD
NTSC
SD
PAL
5
56
IMAGE
SD 4:3
SD
LB
7
7
FLIP
OFF
ONON
8
6 & 7 UP
SD
SQ
68109
TEST
10
BARS
OFF
OFF
ON
910
0
1
2
3
4
5
6
7
HD VIDEO SELECT
720p/59.94
1080i/59.94
1080p/59.94
1080p/60
720p/50
1080i/50
1080p/50
480i/29.97
576i/25
8
9
A
B
C
D
1080p/30
E
1080p/25
F
Set the HD output resolution for the camera with the Rotary Switch.
Set the IR frequency of the camera if it is to respond to the IR remote control.
If using RS-232 for control, leave the IR OUT OFF (SW3) and choose 9600bps for most applications.
If using the IR forwarding feature, turn the IR OUT ON (SW3).
If inverting the camera, turn the IMAGE FLIP ON (SW8).
Dip Switch Settings:
IR 1 & 2: The IR remote has the capability of operating up to three different PTZ cameras from one remote. Use the selector buttons at the top of the IR remote to select the frequency.
IR Out 3: The IR output is sent out on the RS-232 RJ-45 jack on the back of the camera. Turning on the IR
output will allow IR signals to be transmitted over the CAT-5 cable to the head end. When using RS-232 control
or Vaddio CCU controllers (also via RS-232), turn the IR OUT to OFF.
Baud Rate 4: The options for baud rate are either 9600 bps or 38,400 bps. Default is 9600 bps.
SD Format 5: Choose between NTSC or PAL formats
SD Configurations 6 & 7: SD video can be set to standard 4:3, squeeze mode or letterbox mode.
Image Flip 8: To invert the HD-19, turn the IMAGE FLIP ON (switch down).
Test Bars 9: Turning on the non-standard test bars will override the camera video output. These non-standard
test bars are 75% IRE.
Switch 10: Leave up - or in the OFF position
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 8 of 20
WallVIEW CCU HD-19
Installation Basics:
The WallVIEW CCU HD-19 camera was specifically designed for installation on a vertical wall surface with Cat-5e
cable connectivity for Video, Power and Control signaling (three Cat-5e cables are required). Installation is
simplified in that no custom 8-Pin mini-din cables or expensive plenum coax cables are needed and no power
outlets are required near the camera bracket. All cabling is routed to the head-end using Cat-5e cables. “Pass-
thru” type RJ-45 connectors should never be used (see notice on page 3 and comments below).
Before Installing:
Locate the camera mounting location paying close attention to camera viewing angles, lighting conditions,
possible line of site obstructions, and checking for in-wall obstructions where the camera is to be mounted.
Pick a mounting location that will optimize the performance of the camera.
The Thin Profile Wall Mount for the WallVIEW HD-19 can be mounted directly to a 2-gang wall box or can be
mounted to the drywall using four dry wall anchors.
Pre-wire all cabling as required, test and mark the cables POWER, VIDEO and CONTROL. Do not guess at
the cable’s function and try the “process of elimination method” and plug the POWER cable into all the RJ-45
jacks to see which one cable powers the camera. In all likelihood, this method will cause damage to your
system and your warranty will be voided.
RS-232 Cabling:
For RS-232, use a standard straight through RJ-45 connectors (568B termination) from the RS-232 port on
the back of a Vaddio camera controller or switcher to the camera. If the camera is connected to a third-party
control system (such as AMX or Crestron), a DB-9 to RJ-45 control adapter cable is supplied.
Please do not use “pass-thru” type RJ-45 connectors. The Vaddio Cat-5e wiring standard uses pins 7
and 8 on both the video and the control Cat-5e cables. The pass-through connectors have proven to
provide insufficient connectivity for these important signals. They are “ok” for voice and data, but
not for video and control.
Videoconferencing Codecs and RS-232:
Depending on the videoconferencing codec and RS-232 port used, special DB-9 to RJ-45 adapters may
sometimes be required. Refer to Vaddio’s price list or website for part numbers and codec compatibilities.
Any special adapters and configuration information will be noted.
When using a videoconferencing system, remember to always power up the cameras before booting
up the codec.
Another Note about the IR OUT Dip Switch 4:
When operating the HD-19 camera with the Quick-Connect CCU, the IR OUT dip switch must be
set to the OFF (up) position on the back of the camera. If it is not turned off, it can/will interfere
with proper operation of the HD-19 PTZ camera. This would be, not so good, so please turn the
IR OUT switch OFF.
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 9 of 20
WallVIEW CCU HD-19
Basic System Connectivity with the EZIM CCU and the EZIM CCU Slot Card in the HD-19 Camera
HD-19 Rear with EZIM
CCU Slot Card
Note: HDMI video and
Analog HD YPbPr video
outputs remain active for
local use while a CCU is
being used
PowerRite
Power Supply
36VDC
Power (4pr.)
⇢
RS-232
Cat-5e Cables
Up to 500’ (152.4m)
YPbPr & CBVS (HSDS Differential)
⇢
Vaddio Precision Camera Controller
(Up to 7 PTZ cameras can be controlled)
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 10 of 20
RS-232
HD YPbPr
HD Monitor
(No Catfish Were Harmed in the
Making of the Simulated Video)
Cheap SD
Monitor
WallVIEW CCU HD-19
Basic Installation Instructions:
Step 1:
After determining the optimum location of the camera system, route the required 3
(three) Cat-5e cables from the camera to the Quick-Connect CCU interface
located at the head-end. The three Cat-5e cables should feed-through the oval
slot located on the rear flange of the wall mount. If the bracket is to be mounted
Thin Profile
Camera
Wall Mount
on a 2-gang wall box, use the screws supplied with the wall box cover plate to
attach the Thin Profile Wall Mount. If mounting to the drywall with wall anchors,
use four (4) provided drywall anchors. The mounting holes are slotted and are
90° opposing to provide easy leveling. Level the mount and tighten down the
mounting screws.
Step 2:
Remove the blank panel below the connectors on the back of the camera. Slide
the EZIM CCU Card into the slot on the back of the camera until the connector is
seated into the camera. Tighten the thumb screws on the EZIM CCU Card.
Yet Another Note About the IR OUT Dip Switch 4:
EZIM CCU
Slot Card
When operating the HD-19 camera with the Quick-Connect CCU, the IR OUT dip switch must be
set to the OFF (up) position on the back of the camera. If it is not turned off, it can and will
interfere with proper operation of the HD-19 PTZ camera.
Step 3:
Follow the sample wiring diagram on the previous page for connecting the Cat-5e from the Quick-Connect CCU to
the camera. Additional diagrams are available on our website for installation with other equipment.
IMPORTANT NOTE: Check all Cat-5e cables for continuity in advance of the final
connection. Plugging the POWER Cat-5e Cable into the wrong RJ-45 may cause damage to
the camera system and void the warranty.
Step 4:
Place the camera onto the camera mount, connect the previously marked cables to their proper jacks (please do
not guess - especially on the power Cat-5e). Slide the camera back onto the mount and “stuff” the extra cable
back into the wall cavity (dress the cabling) and use the provided ¼” x 20 screws to attach the camera to the
mount securely.
Step 5:
Connect the Vaddio 36 VDC, 2.78A power supply to the Quick-Connect CCU and AC side the into an AC outlet.
Power will travel down the Power Cat-5e cable to the camera. The camera will “Home” to a centered position
ready for control information from CCU and the camera controller (ProductionVIEW HD or maybe the Precision
Camera Controller). To ensure proper continuity of control and operation of the cameras, the boot order should
be camera first (cameras are always first), the Quick-Connect CCU and lastly, the controller.
Step 6:
Set-up the CCU:
Make sure that the HD video monitor that you are using is set up correctly and is delivering accurate color
reproduction.
Adjust the iris level of the camera so that brighter areas are not washed out.
Adjust the Red & Blue Gain, Gamma, Detail and Chroma controls. Adjust other parameters to taste..
NOTE: Gain (next to Iris) should be left at 0 (zero), unless lighting is inadequate, then turn it to a level where the
signal brightness is at an appropriate level. Gain adds additional noise (grain) to the video the higher it is turned
up.
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 11 of 20
WallVIEW CCU HD-19
General Specifications:
WallVIEW CCU HD-19 High Definition PTZ Camera System
Part Numbers WallVIEW HD-19 North America 999-6947-000 (Black), 999-6947-000AW (Arctic White)
Image Sensor 1/3-Type Exmor High-speed, Progressive Scan CMOS Sensor with 1.3 Megapixels
Video Output Resolutions
Lens/ Focal Length 19X Optical Zoom, F=4.5mm wide to 85mm tele end (F1.6-F2.9), Min. Focus Distance 1.0m
Horizontal Viewing Angle 58.1° Wide End to 3.2° Tele End - 16:9 Format
Video S/N Ratio >52 dB
Minimum Illumination 0.7 LUX (F1.6, 50IRE)
Serial Control Protocol RS-232 (Modified VISCA)
Pan Range Pan: +170 degrees to -170 degrees, Tilt: +90 degrees to -30 degrees, Invertible for Ceiling Mount
Preset Positions 16 (internal), 6 recalled via IR Remote
Tally Light Available through RS-232 Control
Connectors
HD Video Select 16-Position Rotary Switch: Used to set HD Video Resolution Output
Camera Settings 10-Position Dip Switch: Settings for IR Select, Baud Rate 9600, Image Flip, SD LB and SQ, Test Bars
Accessories Thin Profile Wall Mount 535-2000-230 (Black), 535-2000-230W (White)
General Information
Operating Temperature 32° to 104° F (0° to 40° C) / 20% to 80% Relative Humidity
Dimensions (H x W x D) 8.5” (215.9mm) H x 6.75” (171.45mm) W x 7.7” (195.58mm) D
Weight 5.79 lbs. (2.625635463kg.)
WallVIEW HD-19 International 999-6947-001(Black), 999-6947-001AW (Arctic White)
12 VDC Power Input: EIAJ-04 Coaxial Power Connector
HD Video Outputs: YPbPr on DE-15 (D-Sub 15-pin HD)
SD Video Output: BNC Connector
RS-232/IR Out: RJ-45 Jack (RS-232 Communication and IR Out (with Quick-Connect -SR Interfaces)
EZ Power HD Video: RJ-45 Jack, for use with Quick-Connect SR Interface or Quick-Connect DVI/HDMI SR
Interface. Supplies power to the camera and returns HD video from the camera to the Quick-Connect - SR
Systems.
OSD (On Screen Display) for fine tuning
EZIM HD-SDI Slot Card PN# 998-6900-007
EZIM CCU Slot Card PN# 999-6900-006 - For Use with Quick-Connect CCU Only
WARRANTY INFORMATION
(See Vaddio Warranty Policies posted on vaddio.com for complete details):
Hardware* Warranty: One year limited warranty on all parts. Vaddio warrants this product against defects in materials and workmanship for
a period of one year from the day of purchase from Vaddio. If Vaddio receives notice of such defects during the warranty period, they will, at
their option, repair or replace products that prove to be defective.
Exclusions: The above warranty shall not apply to defects resulting from: improper or inadequate maintenance by the customer, customer
applied software or interfacing, unauthorized modifications or misuse, operation outside the normal environmental specifications for the
product, use of the incorrect power supply, improper extension of the power supply cable or improper site operation and maintenance.
Vaddio Customer Service: Vaddio will test, repair, or replace the product or products without charge if the unit is under warranty and is
found to be defective. If the product is out of warranty, Vaddio will test then repair the product or products. The cost of parts and labor charge
will be estimated by a technician and confirmed by the customer prior to repair. All components must be returned for testing as a complete
unit. Vaddio will not accept responsibility for shipment after it has left the premises.
Vaddio Technical Support: Vaddio technicians will determine and discuss with the customer the criteria for repair costs and/or replacement.
Vaddio Technical Support can be contacted through one of the following resources: e-mail support at support@vaddio.com or online at
www.vaddio.com.
Return Material Authorization (RMA) Number: Before returning a product for repair or replacement, request an RMA from Vaddio’s
technical support. Provide a technician with a return phone number, e-mail address, shipping address, and product serial numbers and
describe the reason for repairs or returns as well as the date of purchase and proof of purchase. Include your assigned RMA number in all
correspondence with Vaddio. Write your assigned RMA number on the shipping label of the box when returning the product. All returns are
subject to a restocking fee without exception (see warranty policies at vaddio.com).
Voided Warranty: The warranty does not apply if the original serial number has been removed or if the product has been disassembled or
damaged through misuse, accident, modifications, or unauthorized repair. Cutting the power supply cable on the secondary side (low voltage
side) to extend the power to the device (camera or controller) voids the warranty for that device.
Shipping and Handling: Vaddio will not pay for inbound shipping transportation or insurance charges or accept any responsibility for laws
and ordinances from inbound transit. Vaddio will pay for outbound shipping, transportation, and insurance charges for all items under warranty
but will not assume responsibility for loss and/or damage by the outbound freight carrier. If the return shipment appears damaged, retain the
original boxes and packing material for inspection by the carrier. Contact your carrier immediately.
Products Not Under Warranty: Payment arrangements are required before outbound shipment for all out of warranty products.
*Vaddio manufactures its hardware products from parts and components that are new or equivalent to new in accordance with industry standard practices.
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 12 of 20
WallVIEW CCU HD-19
Compliance and CE Declaration of Conformity - ClearVIEW HD-19
Compliance testing was performed to the following regulations:
FCC Part 15, Subpart B Class A
ICES-003, Issue 4: 2004 Class A
EN 55022 A: 2006 + A1: 2007(CISPR 22:2005/A1:2005) Class A
AS/NZS CISPR 22: 2009 + A1: 2010 Class A
VCCI V-3/2010.04 Class A
EMC Directive 2004/108/EC Class A
FCC Part 15 Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15, Subpart B, of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his/her own
expense.
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This
device must accept any interference including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the
user’s authority to operate this equipment.
ICES-003 Compliance
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out
in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le
ministère des Communications du Canada.
European Compliance
This product has been evaluated for Electromagnetic Compatibility under the EMC Directive for Emissions and
Immunity and meets the requirements for a Class A digital device. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate measures.
EN 61000-4-4: 2004 + Corrigendum 2006 Electrical Fast Transients
EN 61000-4-5: 2006 Surge Immunity
EN 61000-4-6: 2009 Conducted Immunity
EN 61000-4-8: 2010 Power Frequency Magnetic Field
EN 61000-4-11: Second Edition: 2004 Voltage Dips, Interrupts and Fluctuations
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 13 of 20
WallVIEW CCU HD-19
Compliance and CE Declaration of Conformity - Quick-Connect CCU and EZIM CCU
Compliance testing was performed to the following regulations:
FCC Part 15, Subpart B Class A
ICES-003, Issue 4: 2004 Class A
European Standard EN 55022 A: 1998 + A1: 2000 Class A
European Standard EN 55024: 1998 + Amendments A1: 2001 + A2: 2002 Class A
EMC Directive 89/336/EC Class A
FCC Part 15 Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15, Subpart
B, of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his/her own expense.
Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must
accept any interference including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by Vaddio can affect emission compliance and could void the user’s
authority to operate this equipment.
ICES-003 Compliance
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’emet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numeriques de la classe A préscrites dans le Règlement sur le brouillage radioélectrique édicte par le ministère des
Communications du Canada.
European Compliance
This product has been evaluated for Electromagnetic Compatibility under the EMC Directive for Emissions and Immunity and
meets the requirements for a Class A digital device. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Standard(s) To Which Conformity Is Declared:
EMC Directive 89/336/EC
EN 55022 A: 1998 + A1: 2000 Conducted and Radiated Emissions
EN 55024: 1998 + Amendments A1: 2001 + A2: 2002 Immunity
EN 61000-4-2: Electrostatic Discharge
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: Electrical Fast Transients
EN 61000-4-5: Surge Immunity
EN 61000-4-6: Conducted Immunity
EN 61000-4-8: Power Frequency Magnetic Field
EN 61000-4-11 Voltage Dips, Interrupts and Fluctuations
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 14 of 20
WallVIEW CCU HD-19
Appendix 1: YPbPr Video Pin-Out for the HD-19 Camera & Quick-Connect Analog YPbPr Output
Pin YPbPr
1 Pr
2 Y
3 Pb
4 5 6 Pr GND
7 Y GND
8 Pb GND
9 10 11 12 13 14 15 -
EZIM CCU Slot card Pin out Assignments
(568B Wiring Standard)
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 15 of 20
WallVIEW CCU HD-19
Appendix 3:Communication Specification
Communication Speed: 9600 bps (default)
Start bit: 1
Stop bit: 1
Data bits: 8
12345678
Parity: None
No Flow control
NOTE: The Vaddio ClearVIEW HD-19 Control Protocol is similar, but not identical to the Sony® VISCA™
command set in order to be compatible with several popular control devices. Not all VISCA commands are
supported and there are many HD-19 specific commands in the following Command and Inquiry Lists.
Pin # RJ-45 RS-232 and IR Out Pins
1) Unused
2) Unused
3) Unused
4) IR Output (Diff Signal to Quick-Connect SR)
5) IR Ground (Diff Signal to Quick-Connect SR)
6) GND (GND of IR Short Range - Pin 3)
7) RXD (from TXD of control source)
8) TXD (to RXD of control source)
HD-19 Command List (1/2)
Command Set Command Command Packet Comments
Address Set Broadcast 88 30 01 FF Address Set (Daisy chain)
IF_Clear Broadcast 88 01 00 01 FF IF Clear
Command Cancel 8x 2p FF p:socket number(1,2)
CAM_Power On
Off(Standby)
CAM_Zoom Stop
Tele(Standard)
Wide(Standard)
Tele(Variable)
Wide(Variable)
Direct
Direct(Variable)
CAM_Focus Stop
Far(Standard)
Near(Standard)
Far(Variable)
Near(Variable)
AutoFocus
ManualFocus
Auto/Manual
Direct
Preset Pan Speed Pan/Tilt/Zoom Speed 81 01 7E 01 0B WW SS ZZ FF WW: Pan Speed (0x01-0x18)
Motor Config Hard Motor Stops
BLK.Enhance Pedestal No Support No Support
GMA.Enhance Gamma 8x 01 7E 54 00 00 0p 0q FF pq: Gamma (0x00-0x10)
CRM.Enhance Chroma 8x 01 7E 55 00 00 0p 0q FF pq: Chroma (0x00-0x64)
KNE.Enhance Knee No Support No Support
DIS.Enhance Digital Image
SNR.Enhance Super Noise
AGC.Enhance AGC Mode 8x 01 7E 59 00 FF
CAM_Shutter Reset
CAM_ExpComp On
CAM_ICR
Cut Filter
Off
Up
Down
Direct
Set
Recall
Off
On/Off
Down
Left
Right
UpLeft
UpRight
DownLeft
DownRight
Stop
Absolute Position
Do not attempt to take this product apart at any time. There are no user-serviceable components inside.
Do not spill liquids or liquid type substances onto the device.
Keep this device away from food or liquid.
For smears or smudges on the devices, wipe with a clean, soft cloth.
Do not use any abrasive pads or caustic chemicals at any time on any Vaddio equipment.
Operating and Storage Conditions:
Do not store or operate the device under the following conditions:
Temperatures above 40°C (104°F) or temperatures below 0°C (32°F)
High humidity, condensing or wet environments
In inclement weather
Dusty environments
In a swimming pool or water park
Dry environments with an excess of static discharge
Under severe vibration
On
Off(Standby)
Auto
Manual
One Push WB
On
Off
On
Off
qq:Tilt 0x01-0x14
qqqq: Tilt 0xE890-0x4C2C
On
Off
qq:Tilt 0x01-0x14
rr:Zoom 0x00-0x07
Hard Motor Stops
Soft Motor Stops
On
Off
On
Off
Off
Low
Medium
High
Manual AGC
Auto Exposure Mode
Manual Control Mode
Shutter Priority Mode
Exposure Priority Mode
On - AE Mode Off
Off – AE Mode On
On - ICR filter Out
Off – ICR filter In
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 18 of 20
Do not attempt to take this product apart at any time. There are no user-serviceable components inside.
Do not spill liquids or liquid type substances onto the device.
Keep this device away from food or liquid.
For smears or smudges on the devices, wipe with a clean, soft cloth.
Do not use any abrasive pads or caustic chemicals at any time on any Vaddio equipment.
Operating and Storage Conditions:
Do not store or operate the device under the following conditions:
Temperatures above 40°C (104°F) or temperatures below 0°C (32°F)
High humidity, condensing or wet environments
In inclement weather
Dusty environments
In a swimming pool or water park
Dry environments with an excess of static discharge
Under severe vibration
WallVIEW CCU HD-19 Manual 342-0268 Rev. A Page 19 of 20