DO NOT OPEN THIS UNIT - THERE ARE NO USER SERVICEABLE
PARTS INSIDE. DO NOT REMOVE THE BOTTOM PLATES. LETHAL
VOLTAGES ARE PRESENT WITHIN THE CHASSIS. DO NOT EXPOSE
THIS UNIT TO MOISTURE OR OPERATE IT IF WET.
VACUUM TUBES BECOME HOT ENOUGH TO CAUSE SERIOUS
BURNS. NEVER TOUCH A TUBE WHEN THE UNIT IS ON. IT MAY
TAKE SEVERAL MINUTES FOR THE TUBES TO COOL DOWN AFTER
THE UNIT IS SWITCHED OFF.
DO NOT PLUG INTO AN AC SOURCE UNTIL ALL CONNECTIONS ARE
COMPLETED.
Introduction
VAC VINTAGE HIGH POWER Mk II
MONOPHONIC POWER AMPLIFIER
Operating Instructions
The Vintage High Power is a wideband low-feedback monoblock power amplifier producing
approximately 100 watts per chassis. It is largely based on the legendary Williamson circuit,
which was first published in England in 1947, and was the mainstay of the original high
fidelity movement. Notable features of this circuit include:
-direct-coupled triode input amplifier and phase splitter, resulting in low phase shift
-inherent precise balance of the phase splitter (if properly executed) at all frequencies
and level, resulting in excellent push-pull balance and low distortion
In the refined form presented in the VAC, this circuit delivers true state-of-the-art
performance, and repudiates the more complex designs seen even to this day. The output
stage features independent cathode bias for each tube, which results in excellent sound and
the most stable and maintenance free operation available anywhere.
Premium parts are employed throughout, including 14 pound 22 section bifilar-wound ultrawideband output transformers, polypropylene and polystyrene signal capacitors, high current
rectifiers, low ESR power supply, and proprietary wiring. The quality of parts and careful
layout allows the use of very little feedback for high sonic purity and low distortion.
Unpacking
Each tube socket on the amplifier is covered by a small round sticker. The color of this sticker corresponds to the color
of the sticker on a tube. Fit each tube into the matching socket, first removing the sticker from the tube and socket. The
bias levels for the output tubes have been factory set, but should be checked during the installation procedure.
Installation
Physical requirements:
1)Provide adequate ventilation - allow at least 3 inches above and 1 inch to each side.
2)Do not place in a completely enclosed cabinet.
3)Do not stack other equipment on top of the VAC units.
4)Do not operate on carpet or any other surface that might block air flow.
5)The chassis and power transformers will become hot in normal use.
6)Do not allow the chassis of the VAC components to touch any metal parts, such as the frame of an equipment
rack. This might create a parallel ground path that will degrade the sound of your system.
Electrical connections:
1)Complete all installation steps before plugging the amplifier into the AC mains supply.
2)Connect signal inputs to the power amplifiers. Single ended interconnect cables equipped with RCA phono
plugs provide the input to each channel.
3)Connect loudspeakers between the appropriate pair of binding posts on the back of the power amplifiers. Most
popular speaker cables can be accommodated by the output terminal strips. Output impedance matching is
available for loads of 2, 4, and 8 ohms. Connect one lead of the speaker cable to the "G" position, and the
other to either 2, 4, or 8. The "G" terminal is at ground potential, and the amplifier does not invert phase.
4)Do not connect two amplifier outputs to each other.
5)Connect the AC cord to the power source indicated on the rear panel (100 volts AC, 120 volts AC, 220 volts
AC, or 240 volts AC at 50 or 60 Hertz).
6)Follow the BIAS procedure described in this manual to set the idle current. Check the idle current at 1 minute,
30 minutes, 1 hour, and 2 hours. Also, read the section entitled INSTALLING NEW OUTPUT TUBES.
Operation
Continuous operation is not recommended. If the amplifiers will not be auditioned for a few hours it is best to turn them
off. This avoids undue stress to the KT88 output tubes.
As with all high fidelity products, the sound characteristics of the VAC amplifiers change somewhat as they warm up.
Best sound will be achieved after 15 minutes of operation, with subtle changes occurring for up to one hour. However,
we advise against leaving the equipment on at all times because of the attendant acceleration of output tube wear. Life
of the output tubes averages between 2,000 and 5,000 hours depending upon brand fitted and random variations within
the tubes themselves.
Any time that the VAC Power Amplifier has not been used for a few weeks the sound may be different. This is also
normal for high resolution audio equipment. Optimum sound should return after a few hours of operation, preferably
with an audio signal.
Please note that although your VAC amplifiers have been run for 48 hours at the factory, they will continue to "break
in" for approximately 150 hours. The break in is most pronounced in the ultra-linear mode. Note that the optional
triode mode and ultra-linear mode do not require separate break in periods, and that the ultra-linear mode will improve
even if you only operate the amplifiers in the triode mode (this is in most cases the most listenable way to break them
in).
Also be aware that many components display the need for a new break in period after being transported in unheated
cargo aircraft.
Bias Adjustment
Your VAC Power Amplifier has been shipped with output tube bias preset. This should be checked when you install
your amplifier, and approximately every month thereafter. It must also be set whenever an output tube is changed.
Monitoring and adjustment of the output tubes is quite easy, and requires a simple voltmeter. To start, place the black
test lead in the center test point (TP5) and the red lead in TP1 (the test probes will "snap" into the test point jacks with
moderate pressure). Adjust the associated bias control to obtain the DC voltage reading listed on the top of the chassis.
Perform the same operation for TP2, TP3, and TP4. Finally, since the tubes interact slightly, repeat this procedure two
or three times until the readings are unchanged. Lower bias readings will not damage the amplifier or tubes, but may
affect the sound if more than 1 or 2 volts low. It is most important to have all of the tubes read the same within +/- .5
VDC.
When installing new tubes, adjust the bias controls to the centers of their rotations. Check the bias of all tubes as theamplifier warms up - don't wait ten minutes. Recheck after 10 minutes, one hour, and one week.
Bias levels should be checked monthly to ensure optimum sound quality. Allow the amplifier to warm up for an hourbefore checking. It is not unusual for bias current to change with time, particularly when tubes are new. In fact, the
greatest amount of drift occurs during the first 200 hours of a tube's life. The drift may change direction periodically,
such that the bias control must be increased and then later decreased, or vice versa. Also check bias if the sound seems
to be lacking in detail or dynamics.
Tube Types
The input/splitter tube V1 and the driver tube V2 may be type 12AU7A/ECC82/E82CC or type 12BH7. The output
tubes V3, V4, V5, and V6 may be type KT88, KT88 Super, or type 6550A. Golden Dragon tubes are generally
recommended and have been used extensively during the development of this amplifier. Please feel free to contact VAC
if you require additional information or advice.
Installing New Output Tubes
Replacement tubes are available from VAC and other sources. Output tubes may be KT88 Beam Power Kinkless
Tetrodes or 6550A Beam Power Tetrodes. It is not necessary that they be matched pairs, although an improvement in
measured performance may be achieved in this way. Make certain that each tube fits firmly in its socket. A tube that
fits loosely may not make correct contact on all pins and might "run away" (read on). DO NOT MIX TYPE KT88 AND
TYPE 6550A TUBES. DO NOT MIX BRANDS OF TUBES.
ALL POWER MUST BE OFF. Remove the old tubes after they have cooled down (TUBES BECOME HOT ENOUGH
TO CAUSE SERIOUS BURNS WHEN IN OPERATION AND MAY TAKE SEVERAL MINUTES TO COOL
DOWN). Install the new tubes firmly and fully in the sockets, taking care to observe the direction of the locating ridge
on the plastic center pin of each tube.
Follow the normal turn on procedure and begin the BIAS procedure. While doing this, keep an eye on the plate (the
outermost metal structure) of the output tubes. SWITCH OFF IMMEDIATELY IF THEY BEGIN TO GLOW RED.
This indicates that the tube is "running away", being destroyed rapidly by conducting excessive current. (Note: with
some KT88s a slight dull orange glow may occur over a very small section of the plate, usually at an edge. This is
acceptable and not the same as running away, in which most of the plate will become bright orange or red.)
Tubes may run away for several reasons:
1)The tube is not fully inserted in the socket.
2)The tube fits loosely in the socket and thus can not make correct contact. Such a tube is unusable and should
be returned to its seller.
3)The tube is defective.
4)The bias is misadjusted.
5)There is a problem with the amplifier. Contact VAC or your dealer to arrange service.
In the event that trouble is encountered, try another tube. Stop if the problem persists and consult with your dealer or
VAC.
Follow the BIAS procedure described previously in this manual to set the correct idle current for each tube. Recheck
the idle current at 1 minute, 30 minutes, 1 hour, and 2 hours.
Replacement of Low Level Tubes
All power must be switched off. Allow tubes to cool down. Remove and replace with new tubes of the appropriate types,
noting the location of holes in the socket and pins of the tubes.
Replacement tubes are available from VAC and other sources.