With functionality, exibility, and ease of installation at top of mind, V7 UPS systems are designed
with high grade durable components and materials. Rigorous load and performance testing
ensure safety and protection for the devices connected. Manufactured at ISO certied facilities
with high standard procedures for material handling and inspection.
Page 2
UPS 1500VA Tower
• 1500VA tower UPS with Simulated Sine Wave Output with 10 Outlets
• Boost AVR automatically adjusts for under-voltage ensuring stable power and longer life batteries
• Energy ecient design
• Quick-access front panel for changing batteries
• Audio & Visual alarms for immediate warning of battery, load, and other issues
• EU version includes both EU and UK Power Cords
LCD Indicator
Quick Access Battery Panel
Modem Surge Protection
5 Surge
Protected Outlets
Coaxial Surge Protection
5 Battery +
Surge Protected
Outlets
UPS1TW1500-1N
US
VPNUPS1TW1500-1N
SKU8Q9026
www.V7-world.com
Page 3
UPS 1500VA Rack Mount 2U
• 1500vA Rack Mount UPS with Pure Sine Wave Output with 8 Outlets
• Boost and Buck AVR automatically adjusts for under-voltage and over-voltage ensuring stable power and longer life batteries.
• ECO (Eciency Corrective Optimizer) for energy saving and EPO function (Emergency Power O)
• Programmable power management outlets maximize backup time to critical devices by setting shorter backup time for non-critical devices
• Audio & Visual alarms for immediate warning of battery, load, and other issues
• Includes rail kit for rack installation
Rotatable LCD Panel
UPS1RM2U1500-1N
Surge Protected
Modem Outlets
EPO Function
Protected +
Programmable Outlets
Vertical SetupRack Mount Setup
www.V7-world.com
Quick Access Battery Panel
Included Vertical Setup Feet
Included Rack
Mounting Hardware
Protected Outlets
Included Rack Mounting Hardware
US
VPNUPS1RM2U1500-1N
SKU6B3134
Page 4
UPS 3000VA Rack Mount 2U
• 3000vA Rack Mount UPS with Pure Sine Wave Output with 8 Outlets
• Boost and Buck AVR automatically adjusts for under-voltage and over-voltage ensuring stable power and longer life batteries.
• ECO (Eciency Corrective Optimizer) for energy saving and EPO function (Emergency Power O)
• Programmable power management outlets maximize backup time to critical devices by setting shorter backup time for non-critical devices
• Audio & Visual alarms for immediate warning of battery, load, and other issues
550VA Desktop US750VA Desktop US1500VA Rack Mount 2U US
Model #UPS1DT550-1NUPS1DT750-1NUPS1RM2U1500-1N
SKU6B31326B31336B3134
Backup/Run Time (Full
Load)
Backup/Run Time (Half
Load)
Load Capacity (VA)550VA750VA1500VA
Load Capacity (Watt)330W450W1350W
Transfer Time6 ms (max 10ms)6 ms (max 10ms)4 ms (max 8ms)
Waveform TypeSimulated Sine WaveSimulated Sine WaveSine Wave
InputNEMA 5-15PNEMA 5-15PNEMA 5-15P
Receptacles:10 (5 Surge) NEMA 5-15R10 (5 Surge) NEMA 5-15R8 x NEMA 5-15R
Surge ProtectionL-N:632 JoulesL-N:632 JoulesL-N:720 Joules
Cord Length6 feet / 1.83 m (Attached Cord)6 feet / 1.83 m (Attached Cord)10 feet / 3 m (Attached Cord)
Equipment Protection
Warranty
IndicatorLED: On/O, Power/Battery, UPS Fault
Audible AlarmsBattery is on, Battery is Low, Overload or Wiring FaultBattery is on, Battery is Low, Overload or Wiring FaultBattery is on, Battery is Low, Overload or Wiring Fault
Operating environment 0-90 % RH@ 0-40 °C0-90 % RH@ 0-40 °C0-90 % RH@ 0-40 °C
Data Line Protection
(RJ-11, RJ-45, etc.)
2 minute30 second4.5 minute
8 minute5.5 minute12.7 minute
$100,000 $100,000 $150,000
RJ-11, RJ-45RJ-11, RJ-45RJ-11, RJ-45
Touch LCD: LCD: AC Mode, Battery mode, Load Level, Battery Level,
Input Voltage, Output Voltage, Overload, Fault and Low Battery
LCD: AC Mode, Battery mode, Load Level, Battery Level, Input
Voltage, Output Voltage, Overload, Fault and Low Battery
www.V7-world.com
Page 11
UPS Product Line Overview
UPS 1500VA Tower US3000VA Rack Mount 2U US
Model #UPS1TW1500-1NUPS1RM2U3000-1N
SKU8Q90268Q9025
Backup/Run Time
(Full Load)
Backup/Run Time
(Half Load)
Load Capacity
(VA )
Load Capacity
(Watt)
Transfer Time6 ms (max 10ms)4 ms (max 8ms)
Waveform TypeSimulated Sine WavePure Sine Wave
InputNEMA 5-15PNEMA 5-30P
Receptacles:10 (5 Surge) NEMA 5-15R6 x NEMA 5-20R, 1 x NEMA 5-30R
Surge Protection L-N:316 JoulesL-N:720 Joules
Cord Length6 feet / 1.83 m (Attached Cord)10 feet / 3 m (Attached Cord)
Equipment
Protection
Warranty
Indicator
Audible AlarmsBattery is on, Battery is Low, Overload or Wiring FaultBattery is on, Battery is Low, Overload or Wiring Fault
Operating
environment
Data Line
Protection (RJ-11,
RJ-45, etc.)
3 minute3.7 minute
11 minute11.8 minute
1500VA3000VA
900W2700W
$100,000 $150,000
LCD: AC Mode, Battery mode, Load Level, Battery Level, Input Voltage, Output
Voltage, Overload, Fault and Low Battery
0-90 % RH@ 0-40 °C0-90 % RH@ 0-40 °C
RJ-11, RJ-45RJ-11, RJ-45
LCD: AC Mode, Battery mode, Load Level, Battery Level, Input Voltage, Output
Voltage, Overload, Fault and Low Battery
SNMP Network Card for UPS
UPSSNMP1-1N
2GT711
• Allows control and monitoring of multiple UPS systems across
the network from one computer
• Real-time dynamic graphs of UPS data (voltage, frequency, load
level, battery level)
• Warning notications via audible alarm, broadcast, Email and
SNMP traps
• Historic event data log
• Password security protection and remote access management