1. INSTALLATION
2. SPECIFICATIONS
3. KEYBOARD LAYOUT AND DESCRIPTION
4. INITIAL SETUP
5. INSTRUCTION FOR USE
6. TROUBLE SHOOTING
APPENDIX
Installation Diagram Installation Procedures
DECEMBER 1999
Specifications subject to change without prior notice
PS SERIES
All STAINLESS STEEL BENCH SCALE
OPERATION MANUAL
PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE
ATTEMPT TO OPERATE THE SCALE
This document hosted by: www.oldwillknottscales.com
Page 2
1. INSTALLATION
outlet. If not, do not plug in the adaptor,
contact your dealer immediately.
1.1 Check and make sure that the following accessories are included: This operation manual Indicator x 1
Platform x 1 Pillar x 1
Power adaptor x 1 Screws and tool set x 1
Contact your dealer if any item missed.
1.2 Install the scale very carefully. Refer to Appendix INSTALLATION DIAGRAM for installation method and procedures. Should you encounter any problem in installation, contact your dealer.
1.3 Power on the scale
a. Before plugging the power adaptor into
electricity outlet, check and make sure that the input voltage of power adaptor matches with the output voltage of the
b. Before first time use, plug the main
adaptor into the wall outlet and charge the scale for at least 8 hours.
c. Retain the packing materials for
future transportation purposes.
Caution:
In most cases, this unit is legal for trade only when it is sealed and bearing a serial number. Do not attempt to break the seal or remove the serial number. Contact your dealer for more information or after sales service.
Page 3
2. SPECIFICATIONS 3. KEYBOARD LAYOUT AND DESCRIPTION
Model No. Capacity Division PS-3000 3000g 0.5g PS-6000 6000g 1g PS-12K 12kg 0.002kg PS-30K 30kg 0.005kg PS-3000S 3000g 1g PS-6000S 6000g 2g PS-15KS 15kg 0.005kg PS-30KS 30kg 0.01kg Platform size 280 x 330 mm Power source Built-in rechargeable
battery or power adaptor Max. Tare range Up to 100% of rated capacity Max. Zero range Up to 2% rated capacity
Weight Units
Metric, decimal pound
(Note A) and pound/ounce
Operation
0
o
Environment Non-condensed. R.H.ยก 85%
Specifications subject to change without notice.
Note A: To comply with the law of certain countries,
the avoirdupois weight units may be disabled. Contact your dealer for more information.
1. ON/OFF KEY Press this key to turn scale
on or off.
2. MODE KEY
Press this key to shift among metric and avoirdupois weight units with or without backlight (optional).
3. M+ KEY
Press this key to accumulate present weight value into memory.
Page 4
4. MR KEY
Press this key to recall the accumulated weight value from memory.
5. TARE KEY
Press this key to tare off the weight of a container and get the net weight.
6. ZERO KEY
Press this key to reset weight displayed to zero when unloaded.
7. MC KEY
Press this key clear the accumulated weight stored.
8. ZERO INDICATOR
An arrow will appear and point at this sign to indicate a zero weight status.
10. M+ INDICATOR
An arrow will appear and point at this sign when memory contains of accumulated data.
11. WEIGHT UNIT INDICATOR "kg" indicates the metric unit is being
employed. "lb" indicates the avoirdupois unit is being employed.
12. LO-BAT INDICATOR
When this indicator appears, recharge the scale immediately. Failure to do so may cause unrecoverable damages to the built-in rechargeable battery.
13. IN-CHARGE INDICATOR
Red color: Recharging on process Green color: Charging completed
9. TARE INDICATOR 14. * RESERVED KEY
An arrow will appear and point at this sign Reserved key, no function assigned. when the tare function is being employed.
Page 5
I f
r e q
u ired, adjust the adjustable feet underneath scale to obtain a level position.
d. Press TARE twice e. Scale displays F.3 f. Press and hold MODE until kg or lb
sign appears.
g. Press MODE to shift between kg and
lb sign.
h. To enable the avoirdupois units,
press ZERO when the lb sign appears.
i. To disable the avoirdupois units,
press ZERO when the kg sign appears.
j. After ZERO is pressed, the scale
will return to operation status.
4.2 Internal Setting
4.2.1 Select weight unit
The scale is equipped with metric and avoirdupois weight units. Follow the below steps to enable/disable the avoirdupois units.
a. Turn scale off
b. Press and hold TARE, then press ON/OFF c. Scale displays F.1
4.2.2 Select Auto Power Off Setting The scale is equipped with Auto Power Off Function. The scale will be turned off
automatically if it is not used for 4 minutes. Follow the below steps to enable/disable the Auto Power Off Function
a. Turn scale off
b. Press and hold TARE, then press ON/OFF c. Scale displays F.1 d. Press TARE three times
4. INITIAL SETUP
4.1 Placing the Scale
Place the scale on a hard and strong surface,
vibration, fire and direct sunlight. For accurate weighing, always place this unit
on a level surface.
Page 6
5. INSTRUCTION FOR U S E
5.1 Before Weighing
Make sure that: a. The upper platform cover is inserted
firmly into the platform.
b. The scale is placed on a level and strong
surface.
c. The scale is turned on. d. The ZEROINDICATORison. If not, press ZERO
to set weight displayed to zero.
5.2 Weighing
a. Always place an object onto the platform
gently. Excessive force applied to platform
may cause damages to sensor inside. b. The weight of the object would be displayed
automatically.
c. It is a good practice to remove all loads
from platform after weighing. It would prolong the lifetime of scale.
5.3 Select Weight Unit
Scale displays
f. Press MODE to shift between 0._OFF
4._OFF
g. To enable the Auto Power Off Function,
press ZERO when 4._OFF appears.
h. To disable the Auto Power Off Function,
press ZERO when 0._OFF appears.
i. After ZERO is pressed, the scale will
Page 7
Press MODE to shift among kg
Page 8
5.8 Weight Memory Function
a. To save a weight to memory and auto
weight accumulation
When weight display is stable, press M+ to save the weight into memory. Scale displays P. 1 and M+ INDICATOR indicating total number of entry and the memory is containing data.
b. Recall accumulated weight in memory Press
MR. Scale will display the total number of entry and the total accumulated weight of all entries.
c. Clear data in memory
Press MC after the accumulated weight is being displayed. Scale will display P.0 to indicate all data in memory has been erased.
Caution
All data stored in memory will be erased if: a. The scale is turned off, or, b. The weight unit is changed.
5.9 Recharge the Scale
The scale is equipped with a built-in rechargeable battery. When LO-BAT INDICATOR appears, recharge the scale immediately. Failure to do so may cause unrecoverable damages to the built-in rechargeable battery.
The scale can remain in operation when being recharged.
Charging is completed when the color of the
IN-CHARGE INDICATOR turns green.
Caution:
Insert the rubber cap into the DC inlet of scale except during recharging.
Page 9
Is the stainless steel platter cover placed on the platter? Place the stainless steel platter cover onto the platter. Is the platter inserted to the platform correctly? Insert the platter to platform correctly.
6. TROUBLE SHOOTING
Syndrome Scale cannot be turned on Check: Is the scale charged? Action: Recharge the scale for at least 8
hours before first time use or plug in the power adaptor before power on the scale.
Check Is the power adaptor inserted properly
into both the electricity outlet and the DC inlet of scale.
Action:
Secure both ends of the power adaptor and try again.
Syndrome Check Action:
Check
Action
Syndrome
Check
Action
Rated capacity cannot be reached
Is the TARE INDICATOR on? Turn the scale off. Remove all loads
Is there anything obstructing the platform or pillar?
Remove all obstacles.
Scale displays 00 000
excess the rated capacity of scale? Remove all loads from platform and try again.
Syndrome Scale turned off automatically
Is the Auto Power Off function employed? Refer to 4.2.2 to disable the Auto
Action
Power Off function.
Check Is the LO-BAT INDICATOR on? Check
Apply the power adaptor. Action
Page 10
Syndrome Weighing result is not accurate
Check Is the scale placed in a level
condition?
Action Adjust the adjustable feet to a level
condition.
Check Is the scale affected by airflow,
vibration or RFI?
Action: Place the scale away from all
disturbances.
Check Is the scale calibrated correctly? Action Contact your dealer.
Check Is the correct weight unit employed?
Action Refer to 4.2.1 and 5.3 for weight
unit settings and usage.
7. DAILY CARE A N D MAINTENANCE
Clean the scale with a soft and damp cloth. If necessary, apply a mild detergent. Do not use any high-pressure water spray, harsh, abrasive material, acetone, volatile solvent, thinner or alcohol for cleaning.
7.3 Verify the accuracy of scale periodically. Re-calibrate the scale if necessary. Note: In some countries, calibration is restricted to be done by an authorized/qualified agent only. Contact your dealer for more information.
7.4 The scale must be placed horizontally during transportation or long time storage.
7.5 Store scale in a dry and clean place.
Page 11
APPENDIX APPENDIX
Installation Diagram
Ins
tallation Procedures
1. Insert the platform cover to the platform very carefully.
2. Thread the cable through the pillar.
3. Lift the pillar to upright position.
4. Fix the pillar to the platform base firmly using the screws provided.
5. Fix the indicator to the indicator mounting using the screws provided.
6. Plug the cable plug into the indicator firmly.