Utilitech LF1054-WH1-48T82-U User Manual

Utilitech and UT Design® and Grounded in Quality® are registered trademarks of LF, LLC. All Rights Reserved.
ITEM #0749980
4 FT. 2-LIGHT WRAP LIGHT
MODEL #LF1054-WH1-48T82-U
Français p. 8
Español p. 15
ATTACH YOUR RECEIPT HERE
Questions, problems, missing parts? Contact the customer service department at
1-866-994-4148, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
1
AB15502
PACKAGE CONTENTS
D
C
F
D
B
PART DESCRIPTION QUANTITY PART DESCRIPTION QUANTITY
A B C Diffuser 1
HARDWARE CONTENTS (shown actual size)
AA
Wire Nut
Qty. 3
Fixture Pan
Socket
BB
Short
Machine Screw
Qty. 2
1 4
CC
Wood Screw
Qty. 2
D End Cap 2 E Spring 1
F Ground Wire 1
DD
Drywall Anchor
Qty. 2
A
E
EE
Support Chain
Qty. 1
B
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the product.
WARNING
Shut off power at the circuit breaker or fuse panel before removing the old fixture or installing the new one.
CAUTION
DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT. If you presently have dimmer
controls, you will need to remove them and replace them with regular electrical switches. If you have a three-way dimmer, you will have to replace it with a regular three-way switch. If you are unfamiliar with electrical installations, it is recommended you have a qualified electrician do your installation.
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated Assembly Time: 45 minutes
Tools required for assembly (not included): phillips screwdriver, flathead screwdriver, safety glasses, electrical tape, pliers, wire cutters, wire strippers, step ladder, hammer.
2
ASSEMBLY INSTRUCTIONS
With power disconnected to the electrical box, remove the old fixture. If the old fixture is attached to an electrical box having more that has two (2) wire leads, use tape and markings to keep track of which wires were attached together.
Remove diffuser (C) from fixture pan (A). One of the
1. end caps (D) is fitted with a spring (E) that allows the end
1
cap (D) to pivot away from the diffuser (C). Pull back on the end cap (D) until it clears the diffuser (C) and pull the diffuser (C) up and away and remove. If the end cap (D) does not easily pivot away from the diffuser, DO NOT force it, try the opposite end cap (D).
E
D
A
C
2. Fasten the (2) machine screws (BB) into the electrical box until the heads are protruding about 1/2 in. from the box.
Hardware Used
BB
Machine Screw
x 2
3. Located in the center of the fixture pan (A) is a round knockout surrounded by 8 keyhole knockouts in various orientations.
Remove the knockouts on the back of the fixture pan (A) that closely match the positions of the machine screws (BB) attached to the electrical box.
It is recommended that a flathead screwdriver (not included) be used to pry the knockout free. If the knockout does not break free, use pliers and bend it back and forth until it snaps off. Trace the black supply lead, white supply lead and the ground wire (F) through the knockout and to the back side of the fixture pan (A).
4. If alternative support is needed to hold the fixture in place, there are several prepunched holes in the fixture pan (A) that can be used to attach the fixture to the ceiling with wood screws (CC). Position the fixture pan (A) over the machine screws attached to the electrical box and, once in place, mark the desired holes on the ceiling. Drywall anchors (DD) need to be installed prior to wiring if fastening to drywall. Remove the fixture and drill a 1/8 in. pilot hole into the marked locations. Insert the drywall anchors into the holes and drive into place until flush with the surface of the drywall. NOTE: If contact is made with wood when drilling the pilot hole, DO NOT install the drywall anchor and instead use a wood screw (CC).
2
BB
BB
3
A
F
4
A
DD
Hardware Used
DD
Drywall Anchor
x 2
3
ASSEMBLY INSTRUCTIONS
A
EE
5. Pull the fixture wires through the hole in the center of the
5
fixture pan (A) to the backside of the fixture. Using the support chain (EE), connect one end to the back of the fixture pan near the center in the specially designed slots and hook the other end to the mounting ears on the electrical box. This will allow for a hands-free support for wiring.
Hardware Used
EE
Support Chain
6. For safety and proper operation, the fixture must be properly grounded. A green or bare copper ground wire
x 1
6
(F) is preattached to the fixture pan (A). If the electrical box is made of plastic and has a green or bare copper ground wire inside, the fixture ground wire (F) must be spliced to the green ground wire in the electrical box using one of the wire nuts (AA). If the electrical box is metal and part of a grounded system and has no visible ground wire, the metal electrical box and metal conduit
EE
are already grounded at or near the circuit breaker panel. The fixture pan (A) will be grounded via the machine screws (BB). If unsure if the electrical box is properly grounded, or the box is plastic and has no ground wire, or are unfamiliar with the methods of properly grounding the fixture, consult a qualified electrician.
Hardware Used
A
EE
AA
F
A
AA Wire Nut
x 1
7. Pull both the white and black fixture wire leads through the center hole and make connections on the back side of the fixture. Connect the supply leads from the electrical box to the fixture wire leads using the wire nuts (AA). The black lead from the fixture pan (A) is spliced to the black supply lead, and the white lead from the fixture pan (A) is spliced to the white supply lead. Ensure the wire nuts (AA) are tight. Wrap electrical tape around the wire nuts (AA) to prevent them from coming loose. Carefully push the spliced wires back into the electrical box and remove support chain (EE).
Hardware Used
AA Wire Nut
x 2
7
AA
AA
AA
4
ASSEMBLY INSTRUCTIONS
8. CEILING JOIST MOUNTING:
While holding the fixture pan (A) in line with the pilot holes, drive the wood screws (CC) into the wooden studs. Tighten until the fixture pan (A) has been secured to the mounting surface.
DRYWALL MOUNTING: For mounting into drywall, hold the fixture pan (A) in line with the drywall anchors (DD) that were installed in step 4 and drive the wood screws (CC) into the drywall anchors (DD). Tighten until the fixture has been secured to the mounting surface.
Hardware Used
CC
Wood Screw
x 2
9. Tighten machine screws (BB) until the fixture has been secured to the electrical box.
Hardware Used
BB
Machine Screw
x 2
8
A
DD
A
CC
CC
9
A
CC
CC
10. Install (2) 32-watt T8/3,000K up to 4,100K/10,000 hour/F32T8 fluorescent bulbs (not included). Do not use any other wattage of linear fluorescent bulb. Install the bulb into the bulb sockets (B) by aligning the pins of the bulb with the slot in the bulb sockets (B). Using your thumb and forefinger, press the metal ends of the bulb, and roll the bulb forward until it rotates 90 degrees inside the bulb socket (B), making contact between the bulb pins and the bulb socket (B) contacts. Repeat for each bulb.
11.
While holding the diffuser (C) with one hand, maneuver the diffuser (C) into the end of the fixture that does not have a spring attached to the end cap (D) until the diffuser (C) seats into the end cap (D).
10
B
B
11
C
D
5
ASSEMBLY INSTRUCTIONS
12.
At the other end of the fixture, pull back on the end
12
cap (D) equipped with the spring (E) until that end of the diffuser (C) clears. Raise the diffuser (C) into place until the diffuser (C) seats and carefully release the end cap,
D
which will pivot back in place and securely hold the diffuser (C).
Restore power to the fixture.
C
E
BULB REPLACEMENT INSTRUCTIONS
When bulb replacement is necessary, replace the bulb with a 32-watt, 120-volt/3,000K up to 4,100K/10,000 hour/F32T8 fluorescent bulb.
Before replacing the bulb, shut off power to the fixture at the circuit breaker or fuse panel. Allow sufficient time for fixture and bulb to cool.
1.
Remove diffuser (C) from fixture pan (A). One of the
end caps (D) is fitted with a spring (E) that allows the end
1
10
A
cap (D) to pivot away from the diffuser (C). Pull back on the end cap (D) and gently pull the diffuser (C) out of the end cap (D).
D
C
2. Remove the defective bulb by and roll the bulb 90 degrees inside the socket disengage the bulb contact pins from the socket contacts. Then slide the bulb pins out of the socket
3. Install the new bulbs in the same manner as old bulbs were removed.
using thumbs to press
(B)
. This will
(B)
(B)
.
2
Re-install the diffuser (C).
Restore power to the fixture.
4. Dispose of the old bulb(s) in accordance with local, state, and/or federal laws.
E
B
6
CARE AND MAINTENANCE
Periodically clean the fixture using a mild, non-abrasive soap based cleaner and soft cotton cloth. Do NOT use solvents, cleaners containing abrasive agents, ammonia, or surfactants. When cleaning the fixture, make sure you have the power turned off and do not spray liquid cleaner directly onto the diffuser, bulb, socket, ballast, or wiring.
TROUBLESHOOTING
Minor problems often can be fixed without the help of an electrician. Before doing any work on the fixture, shut off power supply at the circuit breaker panel to avoid electrical shock.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fixture doesn’t light.
Circuit breaker trips when light is turned on.
In the unlikely event that your fixture’s ballast or lamp socket(s) fail, they can be replaced by a qualified electrician. For further information regarding these replaceable parts, please have your electrician contact our technical support number at 1-866-994-4148.
WARRANTY
The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of (3) years from the date of original purchase by the consumer. We will repair or replace (at our option) the unit in the original color, and style if available, or in a similar color and style if the original item has been discontinued, without charge, exclusive of bulbs. Defective units must be properly packed and returned to the manufacturer with a letter of explanation and your original purchase receipt showing date of purchase. Call Authorization number and an address where to ship your defective product. Note: No C.O.D. shipments will be accepted. The liability of the manufacturer is in any case limited to replacement of the defective light fixture product. The manufacturer will not be liable for any other loss, damage, or injury which is caused by the product. This limitation upon the liability of the manufacturer includes any loss, damage, or injury which is (I) to person or property or otherwise; (II) incidental or consequential in nature; (III) based upon theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale, use, or repair of the product. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
1. Power is off.
2. Bad wire connection.
3. Defective bulb(s).
4. Defective wall switch.
1. Crossed wires or power wire is grounded out.
1. Check circuit breaker or wall switch.
2. Check wire splices.
3. Replace bulb(s).
4. Replace switch.
1. Check wiring connections.
1-866-994-4148
to obtain a Return
REPLACEMENT PARTS LIST
For replacement parts, call our customer service department at 1-866-994-4148, 8 a.m. - 6 p.m., EST, Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
PART DESCRIPTION PART # C Diffuser ZD-LF1054L48-CDP
AA Wire Nut ZH-LF1054F48-WH1 BB Machine Screw ZH-LF1054F48-WH1
7
AA
Printed in China
BB