UTICA BOILERS TS-100, TS-30, TS-3M, TS-35, TS-SN-1 Instruction Manual

...
Instruction Manual
in.-oz. in.-lb. Nm cm-kg
in.-oz. in.-lb. Nm cm-kg
Preset Models
Miniature Models
Model No.
Torque Range
Drive
Adjustable Model (US Standard)
Preset Model
Torque Range
Model No.
Standard Models
Hex Drive
Adjustable Models (US Standard)
Adjustable Model (Metric)
45-8447
®
Utica
TS & TT Series
Torque Limiting Screwdrivers
TS-30 TT-1TS-SN-1 TT-SN-1
45-8447
Utica
®
Torque Limiting Screwdrivers
Recalibration of the Utica Adjustable Torque Screwdrivers
Proper calibration equipment is required to ensure accuracy!
Adjust to the min. torque output. TS-30 = 6 in-lb TS-35 = 6 in-lb TS-3M = 5 cm-kg TS-100 = 20 in-oz TT-1 = 2 in-oz
If calibration is not correct, adjust the screwdriver to achieve an output equal to that shown in step 1.
Turn adjusting knob to equal setting of measured torque output.
Torque output should equal the reading on the tester within ±4%.
1
2 3
Adjust to the max. torque output. TS-30 = 30 in-lb TS-35 = 35 in-lb TS-3M = 30 cm-kg TS-100 = 100 in-oz TT-1 = 20 in-oz
4 5 6
Turn clockwise to increase and counter­clockwise to decrease the maximum torque setting.
Recheck the screwdriver with the maximum setting.
987
Recheck the setting shown in setp 2.
1110