
Instruction Manual
TS-100 20-100 1/4 Female
TS-30 6.0-30 1/4 Female
TS-35 6.0-35 1/4 Female
TS-3M 0.7-3.5 1/4 Female
TS-SN-1 20-150 1.25-9.38 0.14-1.06 1.44-10.81 1/4 Female
TS-SN-2 128-640 8.0-40 0.9-4.52 9.22-46.1 1/4 Female
TT-1 5.0-20 Universal
TT-SN-1 5.0-30 0.04-0.21 0.36-2.16 Universal
Adjustable Model (US Standard)
Adjustable Models (US Standard)
Adjustable Model (Metric)
45-8447
®
Utica
TS & TT Series
Torque Limiting Screwdrivers
TS-30 TT-1TS-SN-1 TT-SN-1

45-8447
Utica
®
Torque Limiting Screwdrivers
Recalibration of the Utica Adjustable Torque Screwdrivers
Proper calibration equipment is required to ensure accuracy!
Adjust to the min.
torque output.
TS-30 = 6 in-lb
TS-35 = 6 in-lb
TS-3M = 5 cm-kg
TS-100 = 20 in-oz
TT-1 = 2 in-oz
If calibration is not
correct, adjust the
screwdriver to achieve
an output equal to that
shown in step 1.
Turn adjusting knob to
equal setting of measured
torque output.
Torque output should
equal the reading on
the tester within ±4%.
1
2 3
Adjust to the max.
torque output.
TS-30 = 30 in-lb
TS-35 = 35 in-lb
TS-3M = 30 cm-kg
TS-100 = 100 in-oz
TT-1 = 20 in-oz
4 5 6
Turn clockwise
to increase
and counterclockwise to
decrease the
maximum
torque setting.
Recheck the
screwdriver with the
maximum setting.
987
Recheck the setting
shown in setp 2.
1110

Utica
®
Torque Limiting Screwdrivers
Inserting and Removing Bits
45-8447
1
2 3
Setting the Torque
Total Torque =
Major Scale
+
Minor Scale
1
2
Recalibration of the Utica Adjustable Torque Screwdrivers
Proper calibration equipment is required to ensure accuracy!
Check the screwdriver on the torque tester to compare the readings of the tester to the desired setting of the1.
screwdriver.
To make adjustments, loosen the setscrew with a .035” hex key. With the right thumb and forenger, turn the2.
adjusting screw in a counterclockwise direction until it stops. Then in a clockwise direction, turn it one full
revolution.
Attach the screwdriver to the torque tester with a 1/16” hex key. Adjust screw clockwise or counterclockwise to3.
obtain a reading of approximately 10 in-oz on the torque tester when actuating the screwdriver.
The torque setting should now be made by turning the adjusting screw clockwise (right hand) to increase the4.
torque value and counterclockwise to decrease the torque value. Actuate the screwdriver on the tester drive
and observe the readings of each revolution. Continue adjustments and checking until the desired setting is
achieved.
Note: In some cases if may be necessary to make an additional small adjustment to the adjusting screw. Refer
to Step 3.
Tighten the setscrew to lock the adjusting screw.5.
Note: This torque screwdriver is a precision instrument and should be carefully handled, used and stored. If the unit
is dropped or subjected to abnormal handling or impact it should be checked on a Torque Tester before using.