Recalibration of the Utica Adjustable Torque Screwdrivers
Proper calibration equipment is required to ensure accuracy!
Adjust to the min. torque output. TS-30 = 6 in-lb TS-35 = 6 in-lb TS-3M = 5 cm-kg TS-100 = 20 in-oz TT-1 = 2 in-oz
If calibration is not correct, adjust the screwdriver to achieve an output equal to that shown in step 1.
Turn adjusting knob to equal setting of measured torque output.
Torque output should equal the reading on the tester within ±4%.
1
2 3
Adjust to the max. torque output. TS-30 = 30 in-lb TS-35 = 35 in-lb TS-3M = 30 cm-kg TS-100 = 100 in-oz TT-1 = 20 in-oz
4 5 6
Turn clockwise to increase and counter­clockwise to decrease the maximum torque setting.
Recheck the screwdriver with the maximum setting.
987
Recheck the setting shown in setp 2.
1110
Page 3
Utica
®
Torque Limiting Screwdrivers
Inserting and Removing Bits
45-8447
1
2 3
Setting the Torque
Total Torque =
Major Scale
+
Minor Scale
1
2
Recalibration of the Utica Adjustable Torque Screwdrivers
Proper calibration equipment is required to ensure accuracy!
Check the screwdriver on the torque tester to compare the readings of the tester to the desired setting of the1. screwdriver.
To make adjustments, loosen the setscrew with a .035” hex key. With the right thumb and forenger, turn the2. adjusting screw in a counterclockwise direction until it stops. Then in a clockwise direction, turn it one full revolution.
Attach the screwdriver to the torque tester with a 1/16” hex key. Adjust screw clockwise or counterclockwise to3. obtain a reading of approximately 10 in-oz on the torque tester when actuating the screwdriver.
The torque setting should now be made by turning the adjusting screw clockwise (right hand) to increase the4. torque value and counterclockwise to decrease the torque value. Actuate the screwdriver on the tester drive and observe the readings of each revolution. Continue adjustments and checking until the desired setting is achieved.
Note: In some cases if may be necessary to make an additional small adjustment to the adjusting screw. Refer to Step 3.
Tighten the setscrew to lock the adjusting screw.5.
Note: This torque screwdriver is a precision instrument and should be carefully handled, used and stored. If the unit is dropped or subjected to abnormal handling or impact it should be checked on a Torque Tester before using.