Utica Boilers TriFire TRB 3 Parts list

Page 1
Models
TRIFIRESERIESII
HighEfficiency
OilFiredHotWaterBoiler
TRB4075 TRB4095
TRB4110
TRB5 1 00
TRB5 1 1 5 TRB5 13 5 TRB61 30 TRB61 45 TRB61 6 5
TRB7165 TRB7 1 80
TRB7 190
REPAIRPARTS
&OPTIONALKITS
Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial Number
from data plate on your boiler. Include following information when ordering.
Part Number Part Description Boiler Model Number Boiler Serial Number
An ISO 9001-2008 Certified Company
P/N# 240010070 Rev. A [02/2013]
Page 2
JACKET
1
8
2
10
9
3
4
5
6
7
KEY DESCRIPTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION
Complete Jacket Assembly 550002392 550002393 550002394 550002395
1 Top Panel 109008594AC 109008595AC 109008596AC 109008597AC 2 Rear Panel, Upper 109008607 3 Rear Panel, Lower 109008624 4 Right Side Panel 109008660AD 109008661AD 109008662AD 109008663AD 5 Support Bracket, Lower Rear 109008628 6 Support Bracket, Lower Front 109008625 7 Front Panel 109008606AC 8 Left Side Panel 109008664AD 109008665AD 109008666AD 109008667AD 9 Support Bracket, Upper Front 109008608
10 Support Bracket, Upper Rear 109008626
2
Page 3
HEATEXCHANGER
1
2
7
3
8
9
6
4
16
15
14
13
12
11
10
5
Item Description 4 Section 5 Section 6 Section 7 Section
Heat Exchanger Block (Includes Items
8
1,2,4,6,11,12,13,14,15,16)
1 Control Well in Block 240007709 2 1¼” x ¼” Bushing (for Temperature Pressure Gauge) 240009346 4 1¼” x ¾” Bushing (for Drain Valve) 1060003
6 Sight Glass Replacement Kit 550001932 11 Target Wall Insulation* 240007302 12 Door Hinge Kit (2 hinges included) 550001933 13 Door insulation (hard)* (Front Door) 240007300 14 Door Insulation (soft)* (Inner Burner Door) 240007301 15 Door Rope Gasket* 240007390 16 Burner door with insulation & rope gasket 240007305
Items below Ordered Separately
3 ¼” NPT Plug 240005463
5 Flue Spacer 109007382 109007382 109007382 N/A
7 Top Baffl e (2 Required) 109007385 109007386 109007387 N/A
9 V-Shaped Liner N/A 109008787** 109007316 109007315 10 Oval Liner 109007317 N/A N/A N/A
Heat Exchanger Insulation Center*
Heat Exchanger Instulation Rear* 420001079
‡ Not shown * WARNING: This product contains fi berglass and/or ceramic fi bers. Possible cancer hazard. To avoid this possible hazard, avoid breathing fi berglass wool
& ceramic fi ber dust. May cause irritation to skin, eyes & respiratory tract.
** Used on 5115 and 5135 models only with Beckett NX burner only.
240009307 240009308 240009309 240009310
420001080 420001081 420001082 420001083
3
Page 4
STANDARDCONTROLS&ACCESSORIES
1a
9
8
10
1b
7
1c
6
5
4
3
2
Key Description Part Number
1a Limit Control 240009347
Limit Control Assembly 3002009
1
2 3 4 5 6 7 8
9
10 Temperature / Pressure Gauge 240009345
* Control Well Grommet for Sensor Wire 240007713 * 1¼" x 1¼" x ¾" Tee PF05901 * 1¼" x ¾" x 1¼" Tee 1510001 * ¾" Safety Relief Valve (30 PSI) VR-001.01
* = not shown
(USA Chimney Vent, All Direct Vent )
Incudes 1a thru 1e
24” Flexible Oil Line Burner Attachment Bolts - 5/16-18 X ¾” LG (Qty 4) ¾” Street Elbow Limit Conrol Mounting Plug ¾" Drain Valve 1 ¼” x 10” Adapter 1 ¼” x 6" Adapter Barometric Draft Control, 5” (4 thru 6 section) Barometric Draft Control, 6” (7 Section only) 14620007
1b Limit Sensor Wire 48” 240007708 1c Wire Harness, Control 240009174 *1d Wire Harness, Circulator 37519501 *1e Connector, ½ Romex 14634012
240007147 240007237 14693040 240007734 240009323 14607012 14607017 240007166
4
Page 5
OILBURNERS
Replacement Burners
Description 4075 4095 4110 5100 5115 5135
Oil Burner - Beckett Chimney Vent w/o Cover Model AFG except 5115 and 5135 use Model NX
Oil Burner - Beckett Chimney Vent with Cover Model AFG except 5115 and 5135 use Model NX
Oil Burner - Becket Direct Vent Model NX 240007531 240009393 N/A 240007532 240009395 240009396 Oil Burner - Riello Chimney Vent Model 40F 240007502 240009399 240009400 240007503 240009401 550002638 Oil Burner - Riello Direct Vent Model 40BF 240007528 240009407 240009408 240007529 240009409 240009410
REPLACEMENT BURNERS - CONTINUED Description 6130 6145 6165 7165 7180 7190
Oil Burner - Beckett Chimney Vent w/o Cover Model AFG except 5115 and 5135 use Model NX
Oil Burner - Beckett Chimney Vent with Cover Model AFG except 5115 and 5135 use Model NX
Oil Burner - Becket Direct Vent Model NX 240007533 NA NA NA NA NA Oil Burner - Riello Chimney Vent Model 40F 550002639 550002640 240009404 240007505 550002641 240009406 Oil Burner - Riello Direct Vent Model 40BF 240007530 NA NA NA NA NA
240007232 240009385 240009386 240007233 240009387 240009388
240007144 240009377 240009378 240007145 240009379 240009380
240007234 240009389 NA 240007235 NA NA
240007146 240009381 NA 240007183 NA NA
5
Page 6
OILBURNERS
BECKETT BURNER REPLACEMENT PARTS - AFG & NX
CAD Cell (AFG & NX) CD-001.01 Power Cord (AFG & NX) 240007129 Oil Pump Solenoid RP04601 Pump, Oil Clean Cut #2184404U 29688 Beckett Burner Cover Kit 240007393
See Burner Manual for illustrations. When ordering, use the above part numbers.
BECKETT BURNER REPLACEMENT PARTS - AFG ONLY
Combustion Air Tube With Custom Flange, AFG70MQASN w/L2 Head 240007638 Combustion Air Tube With Custom Flange, AFG70MKAQN w/V1 Head 240007639 Igniter & Base Plate (Replacement Burner) 1050007 Drawer Assembly, (incl. 3-3/8U Static Plate & L2 head Igniter) Drawer Assembly, (incl. 2-3/4M Static plate, V1 head Igniter) 240007641
Burner Control, 7505P1515 Beckett Genisys (Pre 15s Post 15s) 240008818 Burner Gasket with keyhole 240007392 L2 Head 240007645 V1 Head 240006446 3-3/8U Static Plate BN08102 2-3/4M Static Plate 240007646
BECKETT BURNER REPLACEMENT PARTS - NX ONLY
Combustion air tube with custom fl ange, NX70LC Combustion air tube with custom fl ange, NX70LD Igniter & Base Plate Drawer Assembly (incl. Static Plate, Press Sensor Tube, Igniter, 6 Slot NX Head) Drawer Assembly (incl. Static Plate, Press Sensor Tube, Igniter, 9 Slot NX Head) 240007776 Burner Control 7505P152M Beckett Genisys (Pre 15s Post 2m) 240007777 Burner Gasket with Keyhole 240007778 Head/Leg Assembly, 6-slot NX1 240007779 Head/Leg Assembly, 9-slot NX2 240007780
Air Inlet Adapter, Modifi ed
Pressure Switch 2198501 (0.65" wc) 240007782 Pressure Switch 21985 (0.85" wc) 240007783 Head Adjustment Mechanism 240007784
240007640
240007772 240007773 240007774 240007775
240007781
6
Page 7
REPLACEMENTPARTS
CIRCULATORS
Circulator - Grundfos UP15 CI-006.01 Circulator - Taco CI-001.03
KITS
Description Part Number
Manual Reset Temperature Limit Kit 550001929
Manual Reset High Limit Control 1010003 Manual Reset Wire Harness 240007127 Immersion Well 14662804
Limit Control Assembly (Canada Chimney Vent Only) 3002015
Limit Control 240009347 Wire Harness Control 240009174 Wire Harness Circulator 37519501 Wire Harness Vent Safety 240004880 Limit Sensor Wire 48" 240007708
5” Vent Safety Kit (Required in Canada, USA optional) 550001931
5” Flue Connector 30655 Wire Harness 240007547 Assembly, WMO Control Field 30660
6” Vent Safety Kit (Required in Canada, USA optional) 550001930
6” Flue Connector 30656 Wire Harness 240007547 Assembly, WMO Control Field 30660
FOR DIRECT VENT UNITS ONLY
Kit, Vent Flex, 4” dia x 10’ with Terminal adapter 240006909
Kit, Vent Flex, 4” dia x 15’ with Terminal adapter 240006910
Kit, Vent Flex, 4” dia x 20’ with Terminal adapter 240006911
Terminal Adapter (part of Vent Flex kit) 240006914
Vent Terminal Oil 28972
Riser Terminal (adds 36” height) 29231
Appliance Adapter 3 Pass Oil Boiler 240007535
7
Page 8
UTICA BOILERS
2201 Dwyer Avenue
Utica NY 13501
web site: www.ecrinternational.com
Loading...