KEEP THIS MANUAL NEAR BOILER. RETAIN FOR FUTURE REFERENCE
SERIES SFH-S
CAST IRON
OIL FIRED BOILER
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
PUBLISHED APRIL 1994
APRIL 1994 - UTICA BOILERS
PRINTED IN USA
MADE IN USA
TESTED FOR 15 LBS.
ASME WORKING
PRESSURE
Safety SymbolsSafety Symbols
Safety Symbols
Safety SymbolsSafety Symbols
The following defined symbols are used throughout this manual to notify the
reader of potential hazards of varying risk levels.
DANGERDANGER
DANGER
DANGERDANGER
DANGER - Indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
WW
ARNINGARNING
W
ARNING
WW
ARNINGARNING
WARNING - Indicates a potentially hazardous situation which, if not avoided, COULD
result in death or serious injury
CAUTIONCAUTION
CAUTION
CAUTIONCAUTION
CAUTION - Indicates a potentially hazardous situation which, if not avoided, MAY
result in minor or moderate injury. It may also be used to alert against unsafe practices.
IMPORIMPOR
IMPOR
IMPORIMPOR
1. Keep boiler area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
2. DO NOT obstruct air openings to the boiler room.
3. Modification, substitution or elimination of factory equipped, supplied or specified
components may result in property damage, personal injury or the loss of life.
4. To the owner: Installation and service of this boiler must be performed by a qualified
installer.
5. To the installer: Leave all instructions with the boiler for future reference.
6. When this product is installed in the Commonwealth of Massachusetts the installation
must be performed by a Licensed Plumber or Licensed Gas Fitter.
SHOULD BE DONE ONLY BY A QUALIFIED EXPERT AND INSHOULD BE DONE ONLY BY A QUALIFIED EXPERT AND IN
SHOULD BE DONE ONLY BY A QUALIFIED EXPERT AND IN
SHOULD BE DONE ONLY BY A QUALIFIED EXPERT AND INSHOULD BE DONE ONLY BY A QUALIFIED EXPERT AND IN
ACCORDANCE WITH THE APPROPRIATE UTICA BOILERS MANUAL.ACCORDANCE WITH THE APPROPRIATE UTICA BOILERS MANUAL.
ACCORDANCE WITH THE APPROPRIATE UTICA BOILERS MANUAL.
ACCORDANCE WITH THE APPROPRIATE UTICA BOILERS MANUAL.ACCORDANCE WITH THE APPROPRIATE UTICA BOILERS MANUAL.
INSTALLING OR VENTING A BOILER OR ANY OTHER GAS APPLIANCEINSTALLING OR VENTING A BOILER OR ANY OTHER GAS APPLIANCE
INSTALLING OR VENTING A BOILER OR ANY OTHER GAS APPLIANCE
INSTALLING OR VENTING A BOILER OR ANY OTHER GAS APPLIANCEINSTALLING OR VENTING A BOILER OR ANY OTHER GAS APPLIANCE
WITH IMPROPER METHODS OR MATERIALS MAY RESULT IN SERIOUSWITH IMPROPER METHODS OR MATERIALS MAY RESULT IN SERIOUS
WITH IMPROPER METHODS OR MATERIALS MAY RESULT IN SERIOUS
WITH IMPROPER METHODS OR MATERIALS MAY RESULT IN SERIOUSWITH IMPROPER METHODS OR MATERIALS MAY RESULT IN SERIOUS
INJURY OR DEATH DUE TO FIRE OR TO ASPHYXIATION FROMINJURY OR DEATH DUE TO FIRE OR TO ASPHYXIATION FROM
INJURY OR DEATH DUE TO FIRE OR TO ASPHYXIATION FROM
INJURY OR DEATH DUE TO FIRE OR TO ASPHYXIATION FROMINJURY OR DEATH DUE TO FIRE OR TO ASPHYXIATION FROM
POISONOUS GASES SUCH AS CARBON MONOXIDE WHICH ISPOISONOUS GASES SUCH AS CARBON MONOXIDE WHICH IS
POISONOUS GASES SUCH AS CARBON MONOXIDE WHICH IS
POISONOUS GASES SUCH AS CARBON MONOXIDE WHICH ISPOISONOUS GASES SUCH AS CARBON MONOXIDE WHICH IS
ODORLESS AND INVISIBLE.ODORLESS AND INVISIBLE.
ODORLESS AND INVISIBLE.
ODORLESS AND INVISIBLE.ODORLESS AND INVISIBLE.
TT
ANT!ANT!
T
ANT! READ ALL INSTRUCTIONS BEFORE INSTALLING.
TT
ANT!ANT!
WW
ARNING:ARNING:
W
ARNING:
WW
ARNING:ARNING:
WW
ARNING:ARNING:
W
ARNING:
WW
ARNING:ARNING:
ALL INSTALLATIONS OF BOILERS AND VENTINGALL INSTALLATIONS OF BOILERS AND VENTING
ALL INSTALLATIONS OF BOILERS AND VENTING
ALL INSTALLATIONS OF BOILERS AND VENTINGALL INSTALLATIONS OF BOILERS AND VENTING
PAGE 1
INSTINST
INST
INSTINST
WARNING:WARNING:
WARNING: Improper installation, adjustment, alteration, service or
WARNING:WARNING:
maintenance can cause property damage, personal injury or loss of life.
All installations must conform to the requirements of the authority having jurisdiction. Such
applicable requirements take precedence over the general instructions of this manual.
Where required by the authority having jurisdiction, the installation must conform to the
American Society of Mechanical Engineers Safety Code for Controls and Safety Devices for
Automatically Fired Boilers, ANSI/ASME No. CSD-1.
LOCATE Starfire 3 in front of final position before removing crate. Provide a level solid
base as near chimney as possible and centrally located with respect to the heat distribution
system as practical.
WARNING:WARNING:
WARNING: BOILER MAY NOT BE INSTALLED ON COMBUSTIBLE
WARNING:WARNING:
FLOORING.
Allow 24 inches in the front, top and right hand side for servicing and cleaning, or removing
tankless water heating coil.
It is recommended that 24 IN. be allowed in back of boiler for convenience when skimming
hole is used.
When installed in a utility room, the door should be wide enough to allow the largest boiler
part to enter, or to permit replacement of another appliance such as a water heater.
The boiler shall be installed such that the oil ignition system components are protected
from water (dripping, spraying, rain etc.) during appliance operation and service.
FOR INSTALLATION ON NON-COMBUSTIBLE FLOORS ONLY. The boiler must not be
installed on carpeting or vinyl flooring. Minimum clearances to combustible construction are:
TOP ...................................................................24 IN.
FRONT ..............................................................24 IN.
FLUE CONNECTOR .......................................... 9 IN.
REAR ................................................................24 IN.
LEFT SIDE ........................................................ 6 IN.
RIGHT SIDE ......................................................24IN.
ALLAALLA
ALLA
ALLAALLA
TION PRTION PR
TION PR
TION PRTION PR
OCEDUREOCEDURE
OCEDURE
OCEDUREOCEDURE
NOTE: CLEARANCE FOR ACCESS SHOULD EXCEED FIRE PROTECTION
CLEARANCE.
PAGE 2
VENTILAVENTILA
VENTILA
VENTILAVENTILA
WW
ARNING:ARNING:
W
ARNING:AIR OPENINGS TO COMBUSTION AREA MUST NOT
WW
ARNING:ARNING:
BE OBSTRUCTED. BY FOLLOWING THE CHART BELOW, ADEQUATE
COMBUSTION AIR CAN BE MAINTAINED.
TION & COMBTION & COMB
TION & COMB
TION & COMBTION & COMB
COMBUSTION AIR REQUIREMENTS
(Minimum Opening Requirements)
USTION USTION
USTION
USTION USTION
AIRAIR
AIR
AIRAIR
*UNCONFINED AREA**CONFINED AREA
OutsideInsideOutside Combustion Air
CombustionCombustionVERTICALHORIZONTAL
BTU/HRAir 1 IN.
INPUT/5000 BTU/HR/1000 BTU/HR1 IN.
(Paragraph 4)(See Fig 1)/4000 BTU/HR/2000 BTU/HR
91,000191002346
140,000281403570
175,000351754488
2
Air 1 IN.
(MIN. 100 IN2)(See Fig 2 & 3)(See Fig 4)
2
DUCTSDUCTS
2
1 IN.
2
210,0004221053106
245,0004924561122
280,0005628061140
*Unconfined area: A space whose volume is not less than 50 cubic feet per 1000
BTU per hour of all appliances installed in that space (cubic feet of space = height x
width x length).
**Confined area: A space whose volume is less than 50 cubic feet per 1000 BTU
per hour of all appliances installed in that space (cubic feet of space = height x width x
length).
1. Ventilation of boiler room must be adequate enough to provide sufficient air to properly
support combustion and venting.
2. When a Starfire 3 is located in an unconfined space in a building of conventional
construction frame, masonry or metal, infiltration normally is adequate to provide air for
combustion and ventilation. However, in any building which has been altered to conserve
energy or to minimize infiltration, the boiler area should be considered as a CONFINED
SPACE. If there is any doubt, install air supply provisions for combustion and ventilation in
accordance with section 5.3, Air for Combustion and Ventilation, of the NFPA 54 1988 code,
the recommendations that follow, or applicable provisions of the local building codes.
3. When a Starfire 3 is installed in an unconfined space, in a building of unusually tight
construction, air for combustion and room ventilation must be obtained from outdoors or
PAGE 3
from spaces freely communicating with the outdoors. A permanent opening or openings
having a total free area of not less than 1 square inch per 5,000 BTU per hour of total input
rating of all appliances shall be provided. Ducts may be used to convey make-up air from
the outdoors and shall have the same cross-sectional area of the openings to which they
are connected.
4. When air for combustion and room ventilation is from inside buildings, the confined
space shall be provided with two permanent openings, one starting 12 inches from the top
and one 12 inches from the bottom of the enclosed space. Each opening shall have a
minimum free area of 1 square inch per one thousand (1,000) BTU per hour of the total input
rating of all appliances in the enclosed space, but must not be less than one hundred (100)
square inches. These openings must freely communicate with the interior areas having
adequate infiltration from the outside. See figure 1 below.
FIGURE 1FIGURE 2
5. When the Starfire 3 is installed in a confined space and all air is provided from the
outdoors, the confined space shall be provided with two permanent openings, one
commencing within 12 inches from the top and one commencing 12 inches from the bottom
of the enclosure. The openings shall communicate directly, or by ducts, with the outdoors
or spaces (crawl or attic) that freely communicate with the outdoors. One of the following
methods must be used to provide adequate air for ventilation and combustion.
A. When directly communicating with the outdoors, each opening shall have a minimum
free area of 1 square inch per 4,000 BTU per hour of total input rating of all equipment in
the enclosure. See figure 2 above.
B. When communicating with the outdoors by means of vertical ducts, each opening
shall have a minimum free area 1 square inch per 4,000 BTU per hour of total input rating
of all appliances in the enclosed space. See figure 3 on page 5.
PAGE 4
C. If horizontal ducts are used, each opening shall have a minimum free area 1 square
inch per 2,000 BTU per hour total input rating of all appliances in the enclosed space. See
figure 4 below.
FIGURE 3FIGURE 4
D. When ducts are used, they shall be of the same cross sectional area as the free area
of the area of the openings to which they connect. The minimum dimension of rectangular
air ducts shall not be less than 3 inches.
6. In calculating free area using louvers, grills or screens for the above, consideration
shall be given to their blocking effect. Screens used shall not be smaller than 1/4 inch mesh.
If the free area through a design of louver or grill is known, it should be used in calculating
the size opening required to provide the free area specified. If the design and free area is
not known, it may be assumed that wood louvers will have 20-25% free area and metal
louvers and grills will have 60-75% free area. Louvers and grills shall be fixed in the open
position or interlocked with the boiler so that they are opened automatically during boiler
operation. See chart on page 3 for combustion air minimum opening requirements.
PAGE 5
CONNECTING SUPPLCONNECTING SUPPL
CONNECTING SUPPL
CONNECTING SUPPLCONNECTING SUPPL
1. Suggested piping for steam heating system can be seen in figure 6 below. Actual piping
may vary based on system design and local conditions.
2. For further piping information refer to the I=B=R installation piping guide.
3. See figure 5 below for typical piping for domestic hot water heater.
4. See figures 7 & 8 on page 7 for the suggested piping for a modular steam boiler.
PIPING FOR BUILT IN DOMESTIC HOT WATER HEATER
Y Y
AND RETURN PIPINGAND RETURN PIPING
Y
AND RETURN PIPING
Y Y
AND RETURN PIPINGAND RETURN PIPING
FIGURE 5
FIGURE 6
PAGE 6
SUGGESTED PIPING FOR MODULAR STEAM BOILER
PUMPED RETURN
FIGURE 7
GRAVITY RETURN
FIGURE 8
PAGE 7