Document Number: L66-1815 Rev. A PRELIMINARY
April 2000
nary
ITI Part No. 60-XXX
Installation Instructions
P roduct Summa ry
This panic button can be used throughout the premises for
police, medical, or auxiliary alarm activation. When the
sensor button is pressed, the built-in transmitter sends a signal to the panel.
The water-resistant design helps prevent damage in case the
sensor accidently gets wet.
The sensor can be worn using the belt clip or as a watch or
as a pendant.
I nsta llation C onsidera tions
Use the following guidelines when installing this button.
❑ The transmitter in the button has an open-air range of
up to 500 ft., but the installation environment may
influence this range.
❑ The 3.0 VDC lithium battery will last at least 12
months.
P rogr amming the Se nsor
This section describes the steps for adding the sensor to
panel memory. For complete instructions, refer to the specific panel’s installation instructions.
4. Test the sensor from several locations within the premises to check for consistent response.
R epla cing the S ensor Ba ttery
1. Disassemble the sensor by remo ving the four screws on
the back of the sensor and separate the front and back
plastic.
You must be free of a ll static elec tricity before handling
the transmitter circuit board. Touch a grounded, bare
metal surface before touch ing the circuit board, or wear
a grounding strap.
2. Remove the old battery from its holder and install the
new battery, observing polarity.
Install only the same size and type battery. Do not
substitute another size or type battery.
3. Reassemble the sensor.
Be sure to assemble the sensor correctly to ensure
water resistance. Be especially careful not to nick or
damage the rubber gasket lining.
4. Test the sensor as described in the section “Testing the
Sensor.”
1. Set the panel in the program mode.
2. When prompted by the panel, enter the appropriate
group number (groups 00 through 07).
3. When prompted by the panel, select the desired sensor
number.
4. When prompted by the panel, trip the sensor by pressing the sensor button.
5. Exit from program mode.
Testing the S ensor
1. Set the system to the Dealer Sensor Test mode.
2. Press the button on the sensor.
3. Count the number of signals received by the panel,
indicated by interior siren beeps. Seven to eight beeps
is considered acceptable.
Pa nic Button
Lithium Ba tter y Disposa l
Lithium batteries that are no longer usable are considered
hazardous waste. Be sure to properly dispose of the old battery. Contact your local city government for hazardous
waste disposal laws.
Specifications
Compatibility: All ITI Learn Mode Panels
Power Source: 3 Volt Duracell (DL2032)
Enclosure: Water-Resistant and Shock-Resis-
tant
Dimensions: (L x W x D): 1.5” x 1.25” x .4”
1

Notices
Notices
US Patents 4,855,713, 4,864,636, and others pending.
This device complies with FCC Rules P arts 15 and 68.
Operation is subject to the following two conditions.
1. This device may not cause harmful interference.
2. This device must accept any interference that may be
received, including interference that may cause undesired operation.
FCC ID: B4Z-781A-PANIC
Changes or modifications not expressly approved by Inter-
active Technologies, Inc. can void the user’s authority to
operate the equipment.
Preliminary 4/7/00
651-777-2690
651-779-4890
ITI is a registered trademark of Interactive Technologies, Inc.
2
Panic Button