US Water Systems L1-200, L1-300 User Manual

Page 1
US Water Systems 300 GPD
Premium Wall-Mount Light Commercial
RO System
1 REVISION 1.0, 1-19-15
Page 2
TABLE OF CONTENTS
INTRODUCTION ............................................................................................................................... 3
SAFETY ............................................................................................................................................. 4
FEED WATER AND OPERATION SPECIFICATIONS .................................................................... 5
REJECTION, RECOVERY AND FLOW RATES .............................................................................. 6
SYSTEM INSTALLATION AND START-UP PROCEDURES .......................................................... 7
MEMBRANE ELEMENTS ............................................................................................................... 10
SYSTEM IDENTIFICATION ............................................................................................................ 11
MEMBRANE INSTALLATION, REMOVAL AND REPLACEMENT ................................................ 12
OPERATION DO’S AND DON’TS .................................................................................................. 15
SPECIFICATIONS........................................................................................................................... 16
OPERATION AND MAINTENANCE ............................................................................................... 18
PREPARING UNIT FOR STORAGE OR SHIPMENT .................................................................... 19
REVERSE OSMOSIS TROUBLESHOOTING ................................................................................ 20
TEMPERATURE CORRECTION FACTORS FOR MEMBRANE ................................................... 21
SERVICE ASSISTANCE ................................................................................................................. 21
OPERATION LOG ........................................................................................................................... 23
SYSTEM DRAWING ....................................................................................................................... 24
L1-200 SERIES FLOW DIAGRAM .................................................................................................. 25
L1 - SERIES ELECTRICAL SCHEMATIC 110V/60HZ ................................................................... 26
L1 - SERIES ELECTRICAL SCHEMATIC 220V/50HZ ................................................................... 27
REVERSE OSMOSIS SYSTEM WARRANTY ................................................................................ 28
2 REVISION 1.0, 1-19-15
Page 3
INTRODUCTION
The US Water Systems 300 GPD Light Commercial RO System is a durable piece of equipment which, with proper care, will last for many years. This User’s Manual outlines installation, operation, maintenance and troubleshooting details vital to the sustained per­formance of the system.
If the RO system is altered at the site of operation, or if the feed water conditions change, please consult US Water Systems for assistance.
NOTE: IN ORDER TO MAINTAIN THE MANUFACTURER’S WARRANTY, AN OPERATING LOG SHOULD BE MAINTAINED. COPIES MAY NEED TO BE SENT TO US WATER SYSTEMS FOR REVIEW.
NOTE: PRIOR TO OPERATING OR SERVICING THE REVERSE OSMO­SIS SYSTEM, THIS USER’S MANUAL MUST BE READ AND FULLY UNDERSTOOD. KEEP THIS AND OTHER ASSOCIATED INFOR­MATION FOR FUTURE REFERENCE. THESE DOCUMENTS CAN BE USED TO TRAIN NEW OPERATORS OR QUALIFIED PERSONNEL THAT MAY BE NEAR THE SYSTEM.
3 REVISION 1.0, 1-19-15
Page 4
SAFETY
The Safety section of this User’s Manual outlines the various safety headings used throughout this manual’s text and are enhanced and defined below:
NOTE: INDICATES STATEMENTS THAT PROVIDE FURTHER INFORMATION AND CLARIFICATION.
CAUTION: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CON­DITIONS OR PRACTICES THAT COULD RESULT IN EQUIPMENT OR OTHER PROPERTY DAMAGE.
WARNING: INDICATES STATEMENTS THAT ARE USED TO IDENTIFY CON­DITIONS OR PRACTICES THAT COULD RESULT IN INJURY OR LOSS OF LIFE. FAILURE TO FOLLOW WARNINGS COULD RESULT IN SERIOUS INJU­RY OR EVEN DEATH.
DO NOT UNDER ANY CIRCUMSTANCE REMOVE ANY CAUTION, WARNING, OR OTHER DESCRIPTIVE LABELS FROM THE SYSTEM.
PLEASE READ THE ENTIRE MANUAL BEFORE PROCEEDING WITH THE
INSTALLATION AND STARTUP. FAILURE TO FOLLOW THE ATTACHED INSTRUCTIONS OR OPERATING PARAMETERS MAY LEAD TO THE PRODUCT’S FAILURE, WHICH CAN CAUSE PROPERTY DAMAGE AND/OR PERSONAL INJURY.
DO NOT USE WHERE THE WATER IS MICROBIOLOGICALLY UNSAFE OR OF UN-
KNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE
SYSTEM.
PRETREATMENT MUST BE SUFFICIENT TO ELIMINATE CHEMICALS, ORGANICS OR
INORGANICS THAT COULD ATTACK THE MEMBRANE MATERIAL.
ALWAYS TURN OFF THE UNIT, SHUT OFF THE FEED WATER, AND
4 REVISION 1.0, 1-19-15
Page 5
DISCONNECT THE ELECTRICAL POWER BEFORE WORKING ON THE UNIT.
NEVER ALLOW THE PUMP TO RUN DRY.
NEVER ALLOW THE UNIT TO FREEZE OR OPERATE WITH A FEED WATER TEM-
PERATURE ABOVE 100°F.
FEED WATER AND OPERATION SPECIFICATIONS
NOTE: IT IS VERY IMPORTANT TO MEET THE MINIMUM FEED
WATER REQUIREMENTS. FAILURE TO DO SO WILL CAUSE THE MEMBRANE TO FOUL PREMATURELY AND VOID THE MANUFACTURER’S WARRANTY.
OPERATING LIMITS
Operating Parameters:*
Feed Temperature
System Inlet Pressure
40 - 85°F
45 - 85 PSIG
Maximum Operating Pressure (@77°F) 120 PSIG (Nominal)
Feed Water Requirements:**
Maximum SDI Rating
< 3
Maximum Turbidity 1 NTU
Maximum Free Chlorine and/or Chloramines 0 PPM
pH (continuous) 3 - 11
pH (cleaning - 30 min.) 2 - 12
**If any of the feed water parameters are not within the limits given, consult your local dealer or distributor for assistance.
NOTE: HIGHER TDS AND/OR LOWER TEMPERATURES WILL RE­DUCE THE SYSTEM’S PRODUCTION. 2% OF THE SYSTEM OUT­PUT CAN BE LOST FOR EVERY DEGREE “F” BELOW 77.
5 REVISION 1.0, 1-19-15
Page 6
REJECTION, RECOVERY AND FLOW RATES
US Water Systems 300 GPD Reverse Osmosis Systems are designed to produce perme­ate water at the capacities indicated by the suffix in the system’s name under the condi­tions listed above. For example, the US Water Systems 300 GPD Reverse Osmosis Sys­tem produces 300 gallons per day of permeate water at the listed operating test condi­tions.
The amount of total dissolved solids (TDS) rejected by the membrane is expressed as a percentage. For example, a 98.5% rejection rate means that 98.5% of total dissolved solids do not pass through the membrane. To calculate the % rejection, use the following formu­la:
% Rejection = [(Feed TDS – Product TDS) / Feed TDS] x 100
Example:
98.5% = [(550-8.25)/550] x 100
NOTE: ALL TDS FIGURES MUST BE EXPRESSED IN THE SAME UNITS, TYPI­CALLY PARTS PER MILLION (PPM) OR MILLIGRAMS PER LITER (MG/L).
US Water Systems 300 GPD Reverse Osmosis Systems are designed to reject up to
98.5% NaCl, unless computer projections have been provided or stated otherwise.
The amount of permeate water recovered for use is expressed as a percentage. To cal­culate % recovery, use the following formula:
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100
Example:
28% = (0.14/0.50) x 100
NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS, TYPICALLY GALLONS PER MINUTE (GPM).
6 REVISION 1.0, 1-19-15
Page 7
SYSTEM INSTALLATION AND START-UP PROCEDURES
1. Inspect the system for any damage that could have occurred during shipment. Although all sys-
tems have been individually inspected, complete a quick inspection of the fittings, tubing and other
components.
2. Please provide a reasonable amount of space for installation and leave 6 inches of space below the
filter housings for easy removal during maintenance endeavors.
NOTE: THE REVERSE OSMOSIS SYSTEM SHOULD BE INSTALLED
INDOORS AND IT IS SUGGESTED THAT IT NOT BE IN DIRECT SUNLIGHT OR
EXTREME COLD.
3. Connect the 3/8” tube fitting to an incoming water source. The minimum feed water pressure
should be at least 30 psi. The system’s minimum operating (membrane) pressure is 80 PSI, but the
optimum operating pressure is 100 psi.
NOTE: DO NOT OPERATE AT A PRESSURE EXCEEDING 125 PSI. The operating
pressure can be increased on the face of the booster pump by turning the hex screw clock-
wise.
4. Connect the concentrate 3/8” tubing (waste) line to drain.
5. Turn on the feed water and plug the booster pump transformer into a power supply of 110 volts 60 Hz.
6. This system has been designed with an auto-flush restrictor. This restrictor automatically flushes the
reverse osmosis system for 30 seconds every time it starts up and once every hour when the system is
producing water.
NOTE: THE TANK PRESSURE SWITCH WILL SHUT THE SYSTEM OFF
7 REVISION 1.0, 1-19-15
AUTOMATICALLY WHEN THE BLADDER TANK IS FULL.
Page 8
7. The sediment filter and carbon must be serviced regularly for optimal performance. The water quali-
ty should be checked every two weeks minimum. The pre-filters should be checked once a month
over the first 3 months of operation to determine the filter change frequency. Typically most appli-
cations will not need to change the filters more than twice annually. However, in some applications
sediment or other contaminants in the feed water may require a more frequent filter change.
8. Dispose of the initial product (clean) water until the TDS level/conductivity of the product water sta-
bilizes at the lowest (cleanest) value. Use any TDS or Conductivity meter to monitor the product wa-
ter quality. A minimum quality of 96% NaCl rejection is recommended (See the rejection rate calcu-
lation).
9. Once the system has been flushed and the TDS level has stabilized, the permeate/product line can
be attached to the storage tank. Additional flushing of the storage tank and distribution system
may be required to reach the TDS level that is produced directly after the RO system at all points of
use.
NOTE: ANY CHLORINE EXPOSURE WILL DAMAGE THE MEMBRANE.
10. This system has been factory wired and preset with a pressure switch at 20 - 40 psi, which is only to
be used with a pressurized bladder tank. If using an atmospheric storage tank, a float switch will be
required to turn the system on and off. An electric float switch can be used. The main power can
be switched by using a “piggy back” connector type float switch or an outlet can be wired to switch
power on and off utilizing a float switch. US Water uses an outlet configuration float switch for the
300 GPD RO system. Please see the following typical float diagram and complete system layout.
8 REVISION 1.0, 1-19-15
Page 9
9 REVISION 1.0, 1-19-15
Page 10
10 REVISION 1.0, 1-19-15
Page 11
11 REVISION 1.0, 1-19-15
Page 12
SYSTEM IDENTIFICATION
12 REVISION 1.0, 1-19-15
Page 13
MEMBRANE INSTALLATION, REMOVAL AND REPLACEMENT
Installation and replacing membranes in the pressure vessels is an easy process with the proper infor-
mation and tools at hand. Please refer to the following instructions when removing and replacing mem-
brane elements:
WARNING: ALL PRESSURE GAUGES MUST READ ZERO BEFORE PROCEED­ING. BEFORE ATTEMPTING, DISCONNECT THE POWER FROM THE SYSTEM AND BLEED ALL WATER PRESSURE FROM THE SYSTEM.
1. Remove the end cap from the right (feed water) side of the membrane housings. This is done by remov­ing the two half-moon retaining disks using a #5 Allen wrench, the end plug should then freely slide out of the pressure vessel. The tubing must be disconnected to remove the cap fully.
2. Remove the membrane bag containing the membrane element from the shipping box. The mem- brane should be contained within a plastic oxygen barrier bag.
NOTE: WEAR GLOVES FOR THE FOLLOWING STEPS TO PROTECT THE MEMBRANE
FROM CONTAMINATION.
3. Cut the bag open as close as possible to the seal at one end of the bag, so the bag may be re -used if nec- essary.
13 REVISION 1.0, 1-19-15
Page 14
4. Make sure that all parts are clean and free from dirt. Examine the brine seal, and permeate tube for nicks or cuts. Replace the cap O-rings or membrane brine seal if damaged.
BRINE
SEAL
5. Flow directions should be observed for installation of the membrane element into the pressure vessels.
REPLACING THE MEMBRANE ELEMENT:
WARNING: THE BRINE SEAL MUST BE IN THE SAME POSITION AS IT WAS FOR FACTORY PRE-
INSTALLED MEMBRANE ELEMENT. THE BRINE SEAL IS A RUBBER SEAL THAT PRO­TRUDES ON ONE SIDE OF THE MEMBRANE AND IS ALWAYS ON THE FEED SIDE OF THE MEMBRANE ELEMENT. FOR L1 SERIES RO SYSTEMS THE BRINE SEAL SHOULD BE ON THE RIGHT SIDE OF THE MEMBRANE HOUSING.
14 REVISION 1.0, 1-19-15
Page 15
1. Remove membrane element from the right (feed water) side of the membrane housing. Long nose pliers may be necessary to pull the old membrane element out of the membrane element housing.
2. Lubricate the membrane brine seal and cap o -rings with a non-petroleum based lubricant.
3. Install membrane through the right side (feed water) of the membrane housing with brine seal located on the feed water side.
4. Push the membrane in the housing from right to left (brine seal on the right). Once the membrane is in place make sure it is fully seated in the housing.
5. Lubricate the O-rings on the cap and re-install the cap (6, Figure 1.A) on the right side by gently twisting it, while pushing it onto the housing. Ensure that you do not pinch or fatigue any O-rings while re- in­stalling the end plug. Push the end plug on until the outer diameter of the plug is flush with the outer di­ameter of the pressure vessel. Lubricating the inner and outer O-rings will make the cap installation easi­er.
6. Insert the two half-moon retaining disks until they are fully seated. Subsequently fasten using a #5 Allen wrench.
7. Reconnect any fittings that may have been disconnected when the membrane pressure vessels were dis- assembled.
8. To Start-Up the system, please refer to the Initial Start -Up section of this manual.
CAUTION: WET MEMBRANES ARE SHIPPED IN A PRESERVATIVE SOLUTION. THE
MEMBRANES MUST BE FLUSHED FOR AT LEAST 30 MINUTES TO RE­MOVE THE PRESERVATIVE FROM THE MEMBRANE. DISCARD ALL OF THE PERMEATE, WHICH IS PRODUCED DURING THE FLUSH PERIOD.
15 REVISION 1.0, 1-19-15
Page 16
OPERATION DO’S AND DON’TS
DO:
Change the cartridge filters regularly
Monitor the system and keep a daily log
Run the system as much as possible on a continuous basis
Always feed the pump with filtered water
DON’T:
Permit chlorine to enter membrane housing with the feed water
Shut down the system for extended periods
Operate the system with insufficient feed flow
Operate the pump dry
16 REVISION 1.0, 1-19-15
Page 17
SPECIFICATIONS
17 REVISION 1.0, 1-19-15
Page 18
OPERATION AND MAINTENANCE
The reverse osmosis process causes the concentration of impurities. The impurities
may precipitate (come out of solution) when their concentration reaches saturation levels.
NOTE: PRECIPITATION CAN SCALE OR FOUL MEMBRANES AND MUST BE PRE­VENTED.
1. Periodically observe the quality and quantity of product water from the system.
NOTE: CHECK THE FEED WATER PRESSURE GOING INTO THE REVERSE OSMOSIS
MEMBRANE, A SIGNIFICANT DROP IN PRESSURE COULD INDICATE A FOULED
PRE-FILTER.
2. A 20% increase in TDS when checking the permeate water indicates possible membrane damage,
and the membrane may need to be replaced.
3. It is suggested that a hand held TDS digital meter is used once per week to monitor the water
quality.
NOTE: IF THE TDS OF THE FEED WATER EXCEEDS 1000 PPM, A HIGHER FLOW RATE
FLOW RESTRICTOR SHOULD BE USED TO EXTEND THE MEMBRANE LIFE.
4. It is important to maintain and/or replace the carbon block regularly since the Thin Film Compo-
site membranes are chlorine sensitive. Irreversible damage will occur with any chlorine present
in the feed water. For additional information, please review the manufacturer’s membrane specifi-
cation sheets.
5. The product line has a one way check valve installed. The check valve should be checked
regularly and replaced if it is not properly sealing.
6. Keep the feed water temperature above 4°C (36°F).
NOTE: EXTREMELY COLD FEED WATER WILL LOWER THE PRODUCT WATER
OUTPUT AND INCREASE PUMP PRESSURE.
18 REVISION 1.0, 1-19-15
Page 19
PREPARING UNIT FOR STORAGE OR SHIPMENT
Prior to shipping or storing the system, the system should be cleaned with an appropriate cleaner, flushed with water and protected from biological attack
with an appropriate solution for membrane elements. The membrane housing (s) and plumbing lines of the system must be completely drained. Any water re­maining in the plumbing of a system may freeze, causing serious damage.
Preparing system for storage:
1. Totally fill membrane elements in the membrane housing with 2 % M-100 solution, venting the air outside of the pressure vessels. Use the overflow technique: circulate the M-100 solution in such a way that the remaining air in the system is minimized after the recirculation is completed.
2. Check the pH once a week. When the pH becomes 3 or lower, change the preser- vation solution.
3. Repeat this process at least once a month.
During the shutdown period, the plant must be kept frost-free, or the temperature must not exceed 113°F (45°C).
Preparing unit for shipment:
4. Disconnect the inlet, concentrate, pre-filter, and permeate plumbing.
5. Drain all water from the pre-filter cartridge housings by unscrewing the hous­ings, removing the pre-filter cartridges, and drain the water from the housings.
6. Disconnect the tubing from the connectors on the permeate and concentrate inlets and outlets.
Allow the system to drain for a minimum of eight hours or until the opened ports quit dripping.
After draining is complete, reconnect all of the plumbing.
19 REVISION 1.0, 1-19-15
Page 20
REVERSE OSMOSIS TROUBLESHOOTING
SYMPTOMS POSSIBLE CAUSES CORRECTIVE ACTION
Low supply pressure Increase inlet pressure
Cartridge filters plugged Change filters
Solenoid valve malfunction Replace sol. valve and/or coil
Low Inlet Pressure
Low Permeate Flow
High permeate flow
Poor permeate quality
Membrane fouling
Motor may not be drawing correct current
Leaks Fix any visible leaks
Cold feed water See temperature correction sheet
Low operating pressure See low inlet pressure
Defective membrane brine seal Inspect and/or replace brine seal
Fouled or scaled membrane Clean membranes
Damaged product tube o-rings Inspect and/or replace
Damaged or oxidized membrane Replace membrane Exceeding maximum feed wa-
ter temperature
Low operating pressure See low inlet pressure
Damage product tube o-rings Inspect and/or replace
Damaged or oxidized membrane Replace membrane
Metal Oxide Fouling
Colloidal Fouling
Scaling (CaSO4, CaSO3, BaSO4, SiO2)
Biological Fouling
Organic Fouling
Chlorine Oxidation
Abrasion of membrane by Crystal­line Material
Use clamp-on amp meter to check
See temperature correction sheet
Improve pretreatment to remove metals.
Optimize pretreatment for colloid removal. Clean with high pH anion­ic cleaners. Increase acid addition and antiscalant dosage for CaVO3 and CaCO4. Reduce recovery. Clean with acid cleaners
Shock dosage of Sodium Bi-Sulfate. Con­tinuous feed of Sodium Bi-Sulfate at re­duced pH.
Chlorination and de­chlorination. Replace cartridge filters.
Activated Carbon or other pretreatment. Clean with high pH cleaner.
Check Chlorine feed equipment and de
-chlorination system.
Improve pretreatment. Check all fil­ters for media
leakage.
20 REVISION 1.0, 1-19-15
Page 21
ABNORMAL PERMEATE FLOW
Permeate flow should be within 20% of the rated production, after correcting the feed water temperatures above or below 77°F.
NOTE: TO DETERMINE THE TEMPERATURE CORRECTION FACTOR, LO­CATE THE TEMPERATURE CORRECTION TABLE ON THE FOLLOWING PAGE AND FOLLOW THE DIRECTIONS.
Example:
5 gpm @ 59˚ F (5÷1.42=3.52 gpm) 5 gpm
@ 77˚ F (5÷1=5 gpm)
5 gpm @ 84˚ F (5÷0.89=5.62 gpm)
SERVICE ASSISTANCE
If service assistance is required, please complete the following process:
Contact US Water Systems. Prior to making the call, have the following information avail­able: system installation date, serial number, daily log sheets, current operating parame­ters (e.g. flow, operating pressures, pH, etc.) and a detailed description of the problem.
21 REVISION 1.0, 1-19-15
Page 22
TEMPERATURE CORRECTION FACTORS FOR MEMBRANE
Find the temperature correction factor (TCF) from the table below. Divide the rated permeate flow at 77°F by the temperature correction factor. The result is the permeate flow at the desired temperature. (See example on the next page)
22 REVISION 1.0, 1-19-15
Page 23
OPERATION LOG
Company:
Location:
Week Of:
System Serial #:
HOUR OF OPERATION
FILTER INLET PRESSURE (PSI)
FILTER OUTLET PRESSURE (PSI)
CONCENTRATE PRESSURE (PSI)
PUMP DISCHARGE PRESSURE (PSI)
DATE
TIME
Date of Start
- Up:
Date of Last Clean­ing:
~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~
FEED FLOW (GPM)
PERMEATE FLOW (GPM)
CONCENTRATE FLOW (GPM)
RECOVERY %
FEED TEMPERATURE
FEED TDS (PPM)
PERMEATE TDS (PPM)
REJECTION %
FEED PH
PERMEATE PH
SCALE INHIBITOR FEED (PPM)
IRON (mg/L)
FREE CHLORINE (mg/L)
HARDNESS (GPG CaCO3)
23 REVISION 1.0, 1-19-15
Page 24
SYSTEM DRAWING
24 REVISION 1.0, 1-19-15
Page 25
L1-300 FLOW DIAGRAM
25 REVISION 1.0, 1-19-15
Page 26
L1 - SERIES ELECTRICAL SCHEMATIC 110V/60HZ
26 REVISION 1.0, 1-19-15
Page 27
L1 - SERIES ELECTRICAL SCHEMATIC 220V/50HZ
27 REVISION 1.0, 1-19-15
Page 28
REVERSE OSMOSIS SYSTEM WARRANTY
One-Year Limited Warranty
Warranty Terms
Subject to the terms and conditions set forth hereinafter, US Water Systems (hereafter US Water) warrants to the original purchaser (hereafter the “Customer”) that the systems and products supplied by US Water are free from defects in material and in workmanship for twelve (12) months from the Warranty Commencement Date (as defined below) only when used strictly in accordance with the applicable operating instructions and within the range of the operating conditions specified by US Water for each such product.
This Warranty does not extend to systems, equipment, or components manufactured by oth­ers, nor to systems, equipment, or components manufactured by others and distributed by US Water. This Warranty does not extend to equipment or components manufactured by others which have been incorporated into an US Water product but, if allowable, US Water hereby as­signs, without warranty, to the Customer its interest, if any, under any warranty made by the manufacturer of such equipment or component. This Warranty does not cover disposable items such as fuses, o-rings, regeneration materials/chemicals, or other such disposable items, which must be replaced periodically under the normal and foreseeable operating condi­tions of the goods warranted hereby.
Warranty Commencement Date
The Warranty Commencement Date for each US Water product shall be the later of the date of: (1) receipt by the Customer, or (2) the date of installation at the Customer’s premises pro­vided that such installation must occur within three (3) months of shipment from the US Water’s facility in Indianapolis, IN. In no event shall the Warranty Commencement Date ex­ceed three (3) months from the shipment from US Water’s facility. The Customer shall pro­vide proof of purchase in order to exercise rights granted under this Warranty. If requested by US Water, the Customer must also provide proof of the installation date. Proof of installa­tion shall be returned by Customer to US Water within thirty (30) days after installation by vir­tue of supplying a Warranty Validation Card supplied with each US Water product fully com­pleted and signed in ink by Customer or the installer of the product.
28 REVISION 1.0, 1-19-15
Page 29
Warranty Service
US WATER’S OBLIGATION UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT (AT US WATER’S SOLE DISCRETION) OF ANY PRODUCT, OR
COMPONENT THEREOF, PROVED TO BE DEFECTIVE IN MATERIAL OR WORKMAN­SHIP WITHIN THE COVERED WARRANTY PERIOD.
The Customer, at the Customer’s risk and expense, shall be responsible for returning such product or component, only after obtaining a Return Goods Authorization (RGA) number from US Water, arranging for freight prepaid, and in conformance with any special packaging and shipping instructions set forth on the operation documentation or RGA instructions, or as otherwise reasonably required, to US Water’s address set forth below, together with (1) RGA number issued by US Water at Customer’s request; (2) proof of purchase and, if necessary, proof of installation date; (3) a Return Goods Authorization Form; (4) a description of the sus­pected defects; (5) the serial number of the US Water product alleged to be defective; and (6) a description of the type of water and pretreatment equipment which has been utilized in con­nection with the product, if any. US Water shall, in US Water’s reasonable discretion, be the sole judge of whether a returned product or component is defective in material or workman­ship. Required or replaced products or components shall be returned surface freight. In genu­ine emergency situations, US Water will (at US Water’s sole discretion) forward replacement parts to Customer without waiting for authorized return of the questionable part(s). In such cases, Customer will issue a purchase order or other payment guarantee prior to shipment. If the returned part is found to have been misused or abused, or the defective part is not re­ceived by US Water within thirty (30) days; the Customer will be invoiced for the replacement part(s) provided. This Warranty does not cover or include labor and/or travel to the Custom­er’s premise or location or any other location. Charges of $1000 per day plus associated travel expenses will be incurred by the Customer in providing the Warranty Service at any location other than US Water’s main headquarters; that is if US Water deems that the product is not covered by said Warranty. US Water reserves the right to precondition such travel to Custom­er’s premises upon prepayment of US Water’s anticipated costs of attending such premises.
Voidability of Warranty
This Warranty shall be void and unenforceable as to any US Water product which has been damaged by accident, mishandling, abuse or has been repaired, modified, altered, disassem­bled or otherwise tampered with by anyone other than US Water or an authorized US Water service representative; or, if any replacement parts are not authorized by US Water have been used, or, the product has not been installed, operated and maintained in strict accordance and adherence with the operating documentation and manuals for such product. Any ex­pressed warranty, or similar representation of performance set forth in the operation docu­mentation for media or resin incorporated into an US Water product shall be void and unen­forceable unless the feed water requirements set forth in the operating documentation for such product are unequivocally and strictly adhered to.
29 REVISION 1.0, 1-19-15
Page 30
Limitations and Exclusions
THIS WARRANTY AND REMEDIES DESCRIBED HEREIN AND HEREINABOVE ARE EX­CLUSIVE AND IN LIEU OF ANY AND ALL OTHER WARRANTY OR REMEDIES, EX­PRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL AXEON BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL OR OTHER SIMI­LAR TYPES OF DAMAGES, FOR DAMAGES FOR THE LOSS OF PRODUCTION OR PROFITS, OR INJURY TO PERSON OR PROPERTY. NO PERSON HAS ANY AUTHORITY TO BIND AXEON TO OTHER THAN WHAT IS SET FORTH ABOVE.
THIS WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS AND THE CUS­TOMER MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JU­RISDICTION. THE PARTIES RECOGNIZE AND AGREE, THAT IN ALL RESPECTS THE LAWS OF THE STATE OF CALIFORNIA SHALL APPLY TO AND SHALL GOVERN ANY INTERPRETATION OR LEGAL SIGNIFICANCE OF THIS DOCUMENT.
NO WARRANTY OR OTHER LIABILITY OF AXEON TO CUSTOMER UNDER THIS AGREEMENT OR OTHERWISE WILL IN ANY EVENT EXCEED THE COST OF REPLACE­MENT OF THE APPLICABLE AXEON PRODUCT, PART, OR ACCESSORY THAT IS SUB­JECT TO ANY BREACH OF AXEON’S WARRANTY. AXEON WILL NOT BE LIABLE FOR ANY DAMAGE TO ANY PROPERTY OF CUSTOMER OR TO CUSTOMER’S CUSTOMERS FOR ANY CONSEQUENTIAL, INCIDENTAL, OR ECONOMIC LOSS OR COMMERCIAL DAMAGE WHATSOEVER. REMEDIES HEREIN PROVIDED ARE EXPRESSLY MADE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY OR OTHER OB­LIGATION HEREUNDER EXPRESS OR IMPLIED OR FROM THE OPERATION OF LAW.
30 REVISION 1.0, 1-19-15