USSC 9660 User Manual

Page 1
OWNERS MANUAL
T
A
E
U
N
T
S
D
E
T
I
S
S
T
O
V
E
U
C
S
O
M
S
N
A
P
C
GRAVITY TYPE DIRECT
VENT WALL FURNACE
MODEL # 9660
MAY BE INSTALLED IN A MANUFACTURED HOME (MOBILE HOME).
WARNING: If the information in this
manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
– Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
A
S
D
M
A
S
O
C
E
G
I
S
N
E
C
I
R
A
E
GS
A
R
T
C
A
I
R
I
T
F
I
N
N
O
I
D
E
– Installation and service must be performed
United States Stove Company
227 Industrial Park Road • P.O. Box 151
South Pittsburg, TN 37380
(423) 837-2100
by a qualified installer, service agency or the gas supplier.
Warning: Improper installation, adjustment, alteration, service or maintenance
can cause property damage, personal injury or loss of life. Refer to this manual. Installation and service must be performed by a qualified installer, service agency or the gas supplier.
USSC 1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
851172C 11/97
Page 2
INTRODUCTIONTABLE OF CONTENTS
Introduction...............................................2
Important Information................................2
Gas Specifications....................................2
Furnace Dimensions.................................3
Planning your Furnace Installation........4-5
Installation Instructions for Optional
Blower Kit.........................................5
Operation and Maintenance.................6-7
Venting Instructions..............................7-8
Venting Tables..........................................9
Pipe Installation.................................10-12
Gas Pressure Requirements.................13
Millivolt System Check...........................13
Testing Manifold & Inlet Pressure..........14
LP/Natural Gas Conversion...................14
Troubleshooting................................15-16
Lighting Instruction Label.......................17
Repair Parts (Generator Assembly).18-19
Repair Parts (Main Assembly)..........20-21
Optional Kits...........................................22
Wiring Diagrams...............................23-25
Notes................................................26-27
How To Order Repair Parts...................28
WARNING: Do not operate appliance with the glass door removed, cracked or broken. Re­placement of the glass should be done by a licensed or qualified service person.
CAUTION: Label all wires prior to disconnec­tion when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
Thank you for your purchase of the Model 9660 Gravity type vented wall furnace. By following the instructions in this manual you can be assured of an installation that will add both beauty and value to your home, as well as provide safe, efficient supplemental heat.
Your dealer can be a valuable source of information as well as recommending pro­fessionals who can assist in installation and maintenance.
Improper maintenance may void war­ranty and can cause injury or property damage. Refer to this manual.
IMPORTANT INFORMATION
For safe installation and operation of your fireplace, please note the following:
1. This appliance should only be installed by a qualified installer. Installation must conform with local codes, or in the absence of local codes, with the latest edition of the National Fuel Gas Code, ANSI Z 223.1­1992/NFPA 54-1992.
2. A manufactured home (mobile home) installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable , the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A.
3. Clothing or other flammable material should not be placed on or near the appliance.
4. The flow of combustion and ventilation air must not be obstructed.
GAS SPECIFICATIONS
GAS MAXIMUM
MODEL FUEL CONTROL INPUT 9660N Natural Remote On/Off 24,000 BTU/HR
9660L Propane/LP Remote On/Off 20,000 BTU/HR Manifold Pressure - Natural Gas 3.5" water column pressure
Propane/LP Gas 10" water column pressure Gas Inlet - 3/8" NPT SUPPLY MINIMUM PRESSURE* MAXIMUM PRESSURE
NATURAL GAS 5" W.C.P. 10.5" W.C.P.
PROPANE/LP GAS 11.0" W.C.P. 13.0" W.C.P.
*For the purpose of Input Adjustment.
5. This appliance gives off high temperatures and should be located out of heavy traffic areas and awa y from furniture and draperies.
6. Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.
7. Children should be carefully supervised when they are in the same room as the fireplace.
8. Under no circumstances should this appliance be modified. Do not operate this appliance if any parts have been removed for service.
9. Installation and any repairs to this appliance should be done by a qualified service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
10. Control compartments, burners and air passages in this appliance should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.
11. The appliance's venting system should be inspected at least once a year and immediately cleaned if necessary.
12. Keep the area around the appliance clear of combustible materials, gasoline and other flammable vapors and liquids. Do not use this appliance as a drying rack for clothing, nor should Christmas stockings or decorations be hung in its immediate area.
13. Do not operate this appliance without glass in place. Replace damaged glass only with equivalent glass of equal thickness and size (available from your dealer).
14. Never burn solid fuel (wood, paper, cardboard, coal) in this appliance.
15. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
16. The glass must be replaced in the door , (if removed for service) before operating the appliance.
2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 3
GAS FURNACE DIMENSIONS
27 3/8 28 1/4
15 11/16
35 15/16
37 9/16
TOP VIEW*
37 9/16
32 3/4
16 1/4
*TOP VIEW SHOWN WITHOUT FURNACE TRIM FOR CLARITY.
9 3/4
10 1/2
FRONT VIEW
USSC 3
34 7/8
3 1/2
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
5 1/2
34 1/8
23 5/8
18 11/16
8 5/16
15 11/16
SIDE VIEW
Page 4
PLANNING YOUR FURNACE
INSTALLATION
OPENING OF DOOR
1 Remove top grill 2 Lower bottom grill by pulling down knob. 3 Unlatch door and swing door down.
1
3
FRAMING AND FINISHING
1. Choose furnace location and frame opening as illustrated below in figure 3, 4a & 4b.
2. Place furnace into position and secure to floor with nail flanges.
3. Cold climate recommendation: When installing this furnace against a non­insulated exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes.
16" o.c.
11 1/2"
15 11/16"
HEARTH
A hearth is not required, but it will improve the appearance and provide added safety. We recommend a noncombustible hearth which extends a minimum of 12 inches in front of the appliance.
MANTELS
The height at which a mantel must be placed above the furnace opening depends on the depth of the mantel. See drawing and chart (Fig. 5 & 6) for proper installation height of a combustible mantel piece. Non­combustible mantels may be installed at any height above the furnace opening. NOTE: Use heat resistant paint or finish on the mantel to prevent discoloration.
Fig. 1
2
CAUTION: DO NOT ATTEMPT TO OPEN DOOR WHILE UNIT IS HOT.
LOCATING YOUR FURNACE
(A) Flat on wall (B) Cross corner
NOTE: *When you install your fireplace in (C) Flat or wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front of the appliance.
The 9660 Gravity type vented wall furnace may be installed flat on a combustible-floor or raised up on a hearth to keep the flame at eye level. If the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance must be installed on metal or wood panel extending the full width and depth of the appliance.
B
(C) *Flat on wall corner (D) Cantilever
A
Fig. 3
Fig. 4a
34 1/8"
Fig. 4b
12"
37 3/8"
37 3/8"
37 3/8
57 1/16"
23 5/8"
40 3/8"
12 7/8"
11 1/2"
12"
15 11/16"
28 9/16"
Fig. 5
10"
8"
6"
18"
16"
14"
12"
10"
TOP OF GRILL OPENING
WALL
4"
2"
Fig. 6 - Mantel Chart
CLEARANCE TO
COMBUSTIBLES
BACK 0 inches from standoffs SIDES 0 inches from standoffs FLOOR 0 inches TOP 0 inches CEILING 30 inches SIDE WALL 6 inches
C
D
Fig. 2
4
Minimum wall thickness:
4 inches
Maximum wall thickness:
6 inches
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Non-combustibles materials such as brick, stone or tile must extend flush with or project in front of and/or on the face of the fireplace but must not block any of the grill openings or fire chamber opening.
USSC
Page 5
THIS APPLIANCE IS FOR USE WITH NATURAL OR PROPANE/LP GAS ONLY AS INDICATED ON RATING PLATE.
NOTE: BTU ratings shown on the rating plate area are for elevations up to 2,000 feet. For elevations above 2,000 feet, rating should be reduced at the rate of four (4) percent for each 1,000 feet above sea level.
OPTIONAL BLOWER KIT. MODEL# B60T
Kit includes: 1-Blower Assembly
1-Speed Control Switch 1-Hardware Pack
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70 or current.
GAS PIPE AND BURNER INSTALLATION
Installation must conform to local codes, or in the absence of local codes, to the latest edition of the National fuel Gas Code, ANSI Z 223.1-1992.
A. An accessible manual shut-off valve is required in the gas supply line. A ground joint union is required in the gas supply line to provide for burner removal or servicing.
B. When a vertical section of piping is required for installation, a condensation trap (drip leg) is required.
C. For natural gas, a minimum of 3/8" iron pipe with gas pressure of 5 WC must be used for supply from the meter. Consult with the local gas utility for any questions concerning pipe size.
UNIT SIDE
D. A 1/8" NPT plugged tapping, accessible for test gauges connection, must be installed immediately up stream of the gas supply connection to the appliance.
E. Make gas connection to burner assembly with pipe or listed flexible connection. Seal space between pipe and knockout on firebox with high temp caulk. See Figure 7.
F . T urn gas supply on and check for leaks using a soap and water solution. (DO NOT USE AN OPEN FLAME).
NOTE: The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing where the test pressure is in excess of 1/2 psig. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.
INSTALLATION
1. Open bottom louver door.
2. Slide fan assembly into opening, line up the mounting holes with the screw studs protruding from the floor panel and secure with the (2) nuts provided.
3. Install electrical wiring.
See B60 - Blower Kit instruction sheet for more details (supplied with kit).
NOTE: Electrical wiring and installation must conform to all applicable codes and ordinances and must be done by a qualified electrician.
CAUTION: Electrical power supply must be disconnected prior to servicing the fan.
PIPE COUPLING
SEDIMENT TRAP
Fig. 7
SEAL THIS AREA WITH HIGH TEMP CAULK.
PIPE
MANUAL SHUTOFF VALVE
TEE JOINT
PIPE NIPPLE
CAP
INSTALLATION OF LOGS
1. Place large rear logs against back support bracket, flat spots up.
2. Place front log against front support bracket, flat spots.
3. Place smaller top logs on flat spots of bottom logs as shown in Figure 8.
4. Close Glass Door.
USSC 5
Fig. 8
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 6
OPERATION AND
MAINTENANCE
WARNING:
GAS LINE, THE GLASS FRONT MUST BE REMOVED.
WHEN PURGING THE
LIGHTING PROCEDURE (Fig.9)
1. Depress and turn gas valve knob (A) to "off". Wait sufficient time to allo w gas which may have accumulated in the burner compartment to escape. (At least 5 minutes.)
2. Depress valve knob and turn to "pilot".
3. Depress and hold valve knob while pushing Piezoelectric spark lighter (B). [If pilot does not light using the piezo­electric spark lighter, the pilot can also be lit by placing a match near the pilot while depressing the valve knob] Hold valve knob depressed until pilot remains lit when knob is released (approximately 10 seconds).
4. Turn valve knob to "ON".
5. Wait approximately one minute then turn burner switch (C) to "ON".
6. If unit fails to start, repeat steps one through five.
NOTE: If unit is equipped with remote "on­off" wall switch, switch must be in "on" position for burner to light.
T
O
L
I
P
O
L
T
I
P
O
F
N
F
O
S
it
E
A
B
O
L
T
I
P
O
F
N
F
O
S
it
off
on
TP TH
TP TH
off
on
C
SHUT-DOWN PROCEDURE
1. To tur n off the Main Burner only, use Main Burner switch or turn Valve Knob to "PILOT" position.
2. For complete shut down, slightly depress Valve Knob, turn to "OFF" position.
3. The Burner Assembly has been pre­adjusted for proper flame control. DO NOT ALTER GAS ORIFICE. Unless con v erting from LP to Natural or Vice Versa.
4. Periodic visual checks of the Pilot Flame should be conducted to ensure that the flame is continuously present except when the valve knob is in the "OFF" position.
PILOT BURNER
ADJUSTMENT (Fig. 10)
1. Adjust pilot key to provide properly sized flame. The flame should cover the upper 3/8" of the tip.
2. Test for leaks.
Pilot Key
T
O
L
I
O
L
T
I
P
O
F
N
F
O
S
it
E
A
Fig. 10 - Pilot flame adjustment
P
TP TH
TP TH
7. Ignite pilot - see Lighting Procedure Section.
8. Operate the burner and visually check to make sure the flame pattern appears similar to Figure 11.
NOTE: It is important to periodically perform a visual check of the pilot and the burner flame and to compare then with this illustration.
Fig. 11
ADJUSTING THE FLAME
If flame is too low:
1. Open the glass door.
2. Remove the (2) top small logs and the front log.
3. Adjust the flame higher by closing the air shutter using a standard phillips screwdriver.
If flame is too high:
1. Open the glass door.
2. Remove the (2) top small logs and the front log.
3. Adjust the flame lower by opening the air shutter slightly using a standard phillips screwdriver.
4. CAUTION: Do not open the air shutter to the point where the flame is lifting off of the burner.
NOTE: If you cannot achieve sufficient flame height, contact your local gas supplier to check for proper gas pressure.
Fig. 9
A
NOTE: The gas control is designed to be either fully on or off. Never use control to vary flame height.
NOTE: It is normal for the new furnace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process. It is recommended that you burn your new fireplace for at least two (2) hours the first time you use it. If optional fan kit is installed, leave it turned off during this break-in period.
6
MAINTENANCE
It is important to keep burner and the burner compartment clean. This must be done periodically, at least once per season.
Steps for Cleaning Procedure:
1. Turn off pilot.
2. Open glass door frame assembly.
3. Remove logs.
4. Vacuum burner compar tment, especially around the orifice opening.
5. Reinstall logs.
6. Close glass door frame.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 7
GLASS CLEANING
It will be necessary to clean the glass periodically. During start-up, condensation forms on the inside of the glass and causes dust, lint, etc. to cling to the glass surface. This is normal. Also, initial paint curing can deposit a slight film on the glass.
DO NOT CLEAN GLASS WHEN IT IS HOT. DO NOT USE ABRASIVE CLEANERS ON GLASS OR DOOR.
IMPORTANT! THE VENT-AIR INTAKE SYSTEM MUST BE PROPERLY IN­STALLED TO INSURE PROPER AND SAFE OPERATION. THE VENT-AIR IN­TAKE SYSTEM MUST BE PROPERLY REINSTALLED AND RESEALED TO IN­SURE PROPER AND SAFE OPERA TION. FOR MANUF A CTURED HOME (MOBILE HOME) INSTALLATION: "THIS APPLI­ANCE MUST BE INST ALLED IN ACCOR­DANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND THE MANUFACTURER'S HOME CON­STRUCTION AND SAFETY STAN­DARDS, TITLE CFR, P ART 3280."
V - Vent Termination
M - Mechanical Air
GM- Gas Meter
R - Regulator
VENTING INSTRUCTIONS
The Model 9660 furnace is designed for direct venting through a side wall or roof. Only venting components specifically approved and labeled for this furnace may be used. The flow of combustion and ventilation air must not be obstructed. Minimum clearance between vent pipes and combustible materials is one (1) inch.
CAUTION: ALL JOINTS MUST BE AIR-TIGHT.
THE INSTALLATION OF THIS APPLIANCE MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE LATEST EDITION OF THE NATIONAL FUEL GAS CODE, ANSI 223.1 (Latest Edition).
SIDE WALL VENTING
Location of Vent Termination
IMPORTANT: The minimum clearances given for the vent termination must be strictly adhered to. There must not be any obstruction such as bushes, fences, garden sheds, decks or utility buildings within 24" from the front of the termination hood.
Do not locate termination hood where ex­cessive snow or ice buildup may occur. Check vent termination area after snow­falls, and clear to prevent potential block­age of venting system. When using snow blowers, make sure snow is directed away from the vent termination area.
The vent termination must not be lo­cated:
1. Less than 7 feet above a paved sidewalk or a paved driveway
located on public property.
2. Within 6 feet of a mechanical air sup-
ply inlet to any building.
3. Above a meter/regulator assembly
within 3 feet horizontally of the verti-
cal center-line of the regulator.
4. Within 6 feet of any gas service regulator vent outlet.
5. Less than 1 foot above grade level;
(see section on below ground installation for special venting.)
6. Within the following distances of a
window or a door which can be
opened, any non-mechanical air
supply inlet or the combustion air in-
let of another appliance;
a. 12 inches top and sides. b. 4 feet below.
7. Underneath a veranda, porch or deck
where, a. the veranda, porch or deck is fully open on a minimum of two sides beneath the floor. b. the distance between the top of
the vent termination and the under­side of the veranda, porch, or deck is less than 4 feet.
C
L
18"
V
36"
V
72"
V
GM
C
12"
L
MINIMUM VENT TERMINATION CLEARANCES
From combustible's exterior surfaces, gas meter, air intakes, etc.
USSC 7
12"
V
36"
V
V
12"
V
R
48"
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
V
V
6"
72"
72"
M
V
Page 8
VENTING INSTRUCTIONS
If the exterior of the building is non-combustible the following minimum clearances are applicable:
2"
2"
INSIDE CORNER
OUTSIDE CORNER
12"
2"
24"
48"
2"
12"
48"
If exterior of the building is combustible the following minimum clearances are applicable.
6"
6"
INSIDE CORNER
OUTSIDE CORNER
48"
36"
12"
6"
12"
48"
6"
BALCONY
RECESSED LOCATION
BALCONY
18"
BALCONY - NO SIDE WALL (CROSS SECTION)
24"
20"
HOUSE EXTERIOR WALL
SIDE WALL
RECESSED LOCATION
BALCONY
24"
BALCONY - NO SIDE WALL (CROSS SECTION)
BALCONY
24"
20"
HOUSE EXTERIOR WALL
SIDE WALL
BALCONY WITH PERPENDICULAR SIDE WALL
8
BALCONY WITH PERPENDICULAR SIDE WALL
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 9
VENTING TABLES
H
V
H
V
1
V
T
1
TABLE C
V
T
TABLE A
TABLE A
V = 40' Max.
T
H
TABLE D
TABLE D
H = 12" Min. H = 24" Max.
V
T
H
TABLE B
TABLE B
VH
T
Min. Max.
12 24 36 48 58
V = 40 Max.
T
H = 8' Max.
H
TOP VIEW
VHH+HV
Min. Max. Max. Max.
12239 24438 36637 48836 5 8 10 35 6 8 12 34 7 8 14 33 8 8 16 32 9 8 16 31
TABLE C
1
V = V+V = 40' Max.
T
1
H = 8' Max.
1
TABLE E
TABLE E
H = 12" Min. H = 24" Max.
TABLE F
VHH+H
Min. Max. Max.
122
V
244 366 488
H
1
H
T
TABLE F-1
H
5810 6812 7814 8816 9816
V = 20' Max.
H = 8' Max.
H = H+H = 16' Max.
T
1
1
V
H
1
H
H
T
TABLE F-2 (variation with 3 elbows)
USSC 9
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 10
INFORMATION ON VENTING ROUTES AND COMPONENTS
Since it is very important that the vent system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitation as to vent configurations apply and must be strictly adhered to.
• Max. vertical vent run is 40 ft.
• Max. horizontal vent run is 16 ft.
• A 1/4" rise per foot of horizontal run must be maintained on all horizontal runs.
• It is possible to configure a venting system with 40 feet of vertical vent run and 16 feet of horizontal vent run and include up to (3) three elbows. (See venting tables on page 9.)
IMPORTANT: It is always best to locate the furnace in such a way that a minimum of offsets and/or horizontal run is required.
INSTALLATION
(1) Twist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings, by orienting the four pipe indentations so they match and slide into the four entry slots on the male ends. (Figure 12) Push the pipe sections completely together, then twist-lock one section clockwise approximately one-quarter turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on the Black Pipe or fittings. They may be located by examining the inside of the female ends. (2) Horizontal runs of vent must be supported every three feet. Wall Straps are available for this purpose.
FEMALE LOCKING LUGS
STEP 4:
Position the horizontal vent termination in the center of the 11 1/2" x 12" hole, and attach to the exterior wall with the four wood screws provided. Before attaching the V ent T ermination to the exterior wall, run a bead of non-hardening mastic around it's outside edges, so as to make a seal between it and the wall. The arro w on the vent cap should be pointing up. Insure that proper clearances to combustible materials are maintained. (Figure 14)
WOOD SCREWS
PLANNING YOUR
INSTALLATION
When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. To determine the length of vent pipe required for vertical installations, measure the distance from the appliance flue outlet to the ceiling, the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roofline. For two-story applications, firestops are required at each floor level. If an offset is needed in the attic, additional pipe and elbows will be required.
HORIZONTAL INSTALLATION
STEP 1:
Set the gas appliance in it's desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.
STEP 2:
Direct Vent pipe and fittings are designed with special twist-lock connections. To connect the venting system to the appliance flue outlet, we have supplied a twist-lock appliance adaptor built into the unit at the factory.
MALE LOCKING LUGS
Fig. 12
STEP 3:
With the adaptor and pipe attached to the stove into it's correct location, and mark the wall for a 11 1/2-inch x 12-inch square hole. The center of the square hole should line up with the centerline of the horizontal pipe, as shown in Figure 13. Cut and frame the square hole in the exterior wall where the vent will be terminated. If the wall being penetrated is constructed of non­combustible material, i.e. masonry block or concrete, a 7-inch diameter hole is acceptable.
(1) The horizontal run of vent must ha ve a 1/4-inch rise for every 1 foot of run towards the termination. Never allow the vent to run downward. This could cause high temperatures and may present the possibility of a fire. (2) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be easily blocked or obstructed. Termination clearances are given on page 7 & 8.
HOT
Fig. 13
NOTE: (1) The four wood screws provided should be replaced with appropriate fasteners for stucco, brick, concrete, or other types of sidings. (2) For buildings with vinyl sidings, a Vinyl Siding Standoff (Part 950), should be installed between the vent cap and the exterior wall. (Figure 14). Attach the Vinyl Siding Standoff to the Horizontal Vent Termination. The Vinyl Siding Standoff prevents excessive heat from possibly melting the vinyl siding material.
VINYL SIDING
APPLY SEALANT TO ALL FOUR SIDES
SCREWS
BOLT HORIZONTAL TOP TO VINYL STANDOFF
VINYL SIDING
Fig. 14
STANDOFF
10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 11
VERTICAL TERMINATION
STEP 1:
Set the gas appliance in it's desired loca­tion. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, as shown in Figure 15, to avoid cutting loadbearing members.
PLUMBER'S TAPE CONNECTED TO WALL STRAP
STEP 2:
T o install the round support box/wall thimble in a flat ceiling, cut a 11 1/2" x 12" hole in the ceiling, centered on the hole drilled in Step 1. Frame the hole as shown in Figure
16.
STEP 3:
Assemble the desired lengths of Pipe and Elbows necessary to reach from the Appliance adaptor up through the Round Support box. Insure that all Pipe and Elbow connection are in their fully twist-licked position.
STEP 4:
Cut a hole in the roof centered on the small drill hole placed in the roof in STEP 1. The hole should be of sufficient size to meet the minimum requirements for clearance to combustibles, as specified on page 8. Continue to assemble lengths of Pipe and Elbows necessary to reach from the Ceiling Support Box up through the roof line. A galvanized finish is desirable above the roofline, due to it's higher corrosion resistance.
(1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid excessive stress on the Elbows, and possible separation. W all Straps are available for this purpose. (2) Whenever possible, use 45 degrees Elbows, instead of 90 degrees Elbows. The 45 degrees Elbows offers less restriction to the flow of flue gases and intake air.
STEP 5:
Slip the flashing over the Pipe Section(s) protruding through the roof. Secure the base of the Flashing to the roof with roofing nails. Insure the roofing material overlaps the top edge of the Flashing as shown in Figure 18. Verify that you ha ve at least the minimum clearance to combustibles at the roofline.
CAP AND STORM COLLAR NOT SHOWN FOR CLARITY
WALL STRAP
Fig. 15
(2) 45 ELBOWS
FRAMING
SHINGLES OVERLAP TOP EDGE OF FLASHING
CEILING JOIST
Fig. 17
11 1/2"
12"
1-1/2 INCH LONG WOOD SCREWS
Fig. 16
USSC 11
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 12
STEP 6:
Continue to add pipe sections until the height of the Vent Cap meets the minimum building code requirements described in figure 18. Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining rooflines, steep pitched roofs, and other similar factors can result in poor draft, or down-drafting. In these cases, increasing the vent height may solve this problem.
Nail
Firestop
STEP 7:
Twist lock the Vent Cap.
NOTE:
(1) For multistory vertical installations, a Ceiling Firestop is required at the second floor, and any subsequent floors. (Fig. 19) The opening should be framed to 11-1/2­inch x 12-inch inside dimensions, in the same manner as shown in Figure 16, page
11. (2) Any occupied areas above the first floor, including closets and storage spaces, which the vertical vent passes through, must be enclosed. The enclosure may be framed and sheetrocked with stan­dard construction materials, see page 8 for minimum allowable clearance between the outside of the vent pipe, and the com­bustible surfaces of the enclosure. Do not fill any of the required air spaces with in­sulation.
IMPORTANT NOTICE:
If for any reason it becomes necessary to remove the unit for maintenance and the Dura-vent pipe is detached, the piping MUST be resealed using HEA T SAFE high temperature sealant, available at your lo­cal hearth and heating store.
2 7/16"
2 7/16"
3 15/16"
2 7/16"
Fig. 19
BUILDING CODE REQUIREMENTS
ROOF PITCH MINIMUM HEIGHT
FEET
FLAT TO 7/12 1 OVER 7/12 TO 8/12 1.5 OVER 8/12 TO 9/12 2 OVER 9/12 TO 10/12 2.5 OVER 10/12 TO 11/12 3.25 OVER 11/12 TO 12/12 4 OVER 12/12 TO 14/12 5 OVER 14/12 TO 16/12 6 OVER 16/12 TO 18/12 7 OVER 18/12 TO 20/12 7.5 OVER 20/12 TO 21/12 8
12
H
Fig. 18
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 13
GAS PRESSURE REQUIREMENTS
The number one cause of all operating problems with gas appliances is improper gas pressure!
Such problems as changes in flame color or configuration, gas pilot or burner outages, intermittent operation, changes in heat output, excessive burner noise, etc., are nearly always the result of changes in gas pressure or improper gas pressure at the time of the installation.
The most important item to check during the initial installation and the first thing to check when operating problems occur is gas pressure!
Gas supplies normally enter a typical residence at 1/2 PSI (13"-15"W.C .) (3.KP A). A regulator is then placed inside the residence which drops this pressure to 7" W.C. (1.8KPS) (Nat. Gas).
This "inches to inches" regulator is of adequate capacity to service the gas appliances such as water heater, dryer, furnace, etc.
If this regulator's capacity is not sufficient to add the Model 9660, an additional "inches to inches: regulator must be installed specifically for the fireplace. EXCEPTION: some codes allow 2 PSI (1.4KPA) supplies to enter the residence, in which case "pounds to inches" regulators are used.
The following table provides information on correct gas pressure requirements. Be sure your gas supplier
or plumber carefully follows this table when installing your gas appliance.
DESIRED MINIMUM MAXIMUM MANIFOLD AIR SHUTTER
PRESSURE PRESSURE PRESSURE PRESSURE POSITION NATURAL 7.0" W.C. 5.0" W.C.* 10.5" W.C. 3.5" W.C. 5/16" OPEN L.P. 11.0" W.C. 10.0" W.C.* 13.0" W.C. 10" W.C. 5/16" OPEN
*For the Purpose of Input Adjustment.
MILLIVOLT SYSTEM CHECK
The millivolt system and individual components may be checked with a millivolt meter having a 0-1000 MV range. Before checking the system, be certain the wall thermostat lead wire does not exceed the length recommended in the Wiring Section Table, and all connections are clean and tight.
Conduct each check shown in the chart below by connecting meter test leads to terminals as indicated. All readings are closed circuit.
If the reading is more than 100 millivolts and the automatic valve does not come on, replace the valve operator. If the closed circuit reading is less than 100 millivolts, determine the cause by preceding with steps "B" and "C".
Component Connect Wall Meter See Check Meter Test Thermostat Reading Check
Leads To Contacts Should Be Results Terminals Should Be Below
Valve Operator Greater Than System 2 & 3 Closed 100 MV A Wall Less Than Thermostat 1 & 3 Closed 80 MV C Thermopile Greater Than and Magnet 1 & 2 Open 325 MV B
C. TEST RESULTSB. TEST RESULTSA. TEST RESULTS
If "B" reading is less than 325 MV, clean and tighten all electrical connections and adjust pilot if necessary to increase millivolt output. If unable to adjust to at least the specified minimum, change the thermopile. When proper thermopile output is obtained, the magnet may then be checked. With pilot in operation, allow meter reading to stabilize. Extinguish pilot burner and note meter reading at dropout point of magnet. If magnet remains locked up to a reading of 120 MV or less, the magnet is good.
If "C" reading is more than that specified for the system being checked, clean and tighten thermostat leads and connection, shorten lead wires if possible or use heavier gauge wire. Rapidly cycle thermostat to clean contacts, or change the thermostat.
USSC 13
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 14
TESTING MANIFOLD AND
INLET PRESSURE
GAS
CONVERSION
6. Rotate the conversion cap until the desired gas designation is exposed and reinstall it in the control.
T o test the Manif old gas pressure and Inlet gas pressure in the field, simply follow the instructions below.
NOTE: Manometer attachment may be accomplished by sliding a rubber tube con­nected to the manometer to the pressure taps.
1. Locate the Manifold and Inlet pressure taps on the control. (See Figure 20) NOTE: The following instructions apply for both the Manifold and Inlet pressure tests.
2. With a small screwdriver, rotate the screw in the pressure tap "counter­clockwise" until loosened. NOTE: Screw is designed not to come completely out.
3. Attach Manometer to pressure tap and take reading.
4. Once testing is complete, rotate the pressure tap screw "clockwise" and tighten securely.
1. Open lower door and locate the 1/4" O.D. tubing connecting the control to the bottom of the pilot.
2. Loosen the nut on the tubing at the pilot completely then gently pull down on the pilot tubing to expose the pilot orifice. (Fig. 21)
3. Remove pilot orifice and put correct orifice for the desired gas on the end of the tubing. (Fig. 21)
4. Reinstall the pilot supply tubing, with orifice, in the base of the pilot and tighten nut.
5. Next, locate the conversion cap on the control and remove it. (Fig. 22)
Fig. 21
30 51
LP Pilot Orifice Natural Pilot Orifice
7. Open glass door and remove the ceramic logs.
8. Remove burner screw and then remove burner.
9. Unscrew burner orifice and install orifice for the gas to be used as identified on the unit rating plate. When installing the new orifice you
must use a pipe sealant approved for use with Natural and LP gas.
10.Install burner and burner screw.
11.Check for gas leaks at all connections.
12.Replace ceramic logs and close glass door.
Fig. 20
T
O
L
I
O
L
T
I
P
O
F
N
F
O
S
it
E
A
P
E
A
MANIFOLD PRESSURE TAP
INLET PRESSURE TAP
LP Pilot orifice will be color coded BLACK.
off
TP TH
TP TH
on
Fig. 22
Remove screw with philips driver to lift burner
Conversion Cap
Main Orifice (Remove with 7/16 wrench)
Orifice for Conversion will be attached to piping here
Warning! Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
14
Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 15
TROUBLESHOOTING
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Piezo sparker won't light pilot. 1. Misaligned electrode. 1. Realign electrode so it produces
spark into pilot hood (approximately 1/8" from pilot hood).
2. Incorrect wire connections. 2. Make sure connections are proper.
3. Defective electrode. 3. Replace electrode if shorted out or it has cracked porcelain.
4. Defective push button. 4. Replace push button.
5. No gas present. 5. Turn gas on.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Pilot will not stay lit. 1. Incorrect lighting procedure. 1. Checking lighting instructions found
on label in gas fireplace or in own­ers manual.
2. Pilot flame not making proper 2. Adjust pilot (see page 6).
contact with thermopile.
3. Bad connection between thermopile 3. Make sure screws are snug holding
and screw terminals on gas valve. thermopile. (Do not overtighten or
the screws will become stripped).
4. Wires on wrong terminals. 4. White lead from thermopile must go to top screw TH TP terminal and red wire must go to spill switch wire.
5. Ther mopile is defective, dirty, or 5. Test with millivolt meter and replace
weak. if necessary.
6. Thermopile is shorting out where it 6. Replace thermopile.
passes through cabinet.
7. Gas valve will not prove pilot. 7. Replace valve.
8. Air in line. 8. Purge air from gas line.
9. Wire from valve to wall switch or 9. Remove wall switch wires from top
remote switch is nicked or shorting and bottom screw of millivolt valve. out. If unit is OK and you reconnect the
wall switch and it cuts out again, then replace wires to wall switch.
10. Switch defective or short in circuit. 10. Replace switch.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Pilot stays on but main burner won't 1. Wired incorrectly. 1. See page 22 for correct wiring. come on. 2. Wall switch, on/off switch, or remote 2. Replace wall switch, on/off switch,
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Wall switch must be pushed multiple Defective wall switch. Replace wall switch. times to make flame come on. NOTE: Can use standard single
USSC 15
hand switch defective. or remote hand switch.
3. Not enough voltage being generated 3. Adjust pilot light up to create more
by pilot. voltage or replace thermopile.
4. Defective gas control valve. 4. Replace gas control valve.
pole electrical switch.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 16
TROUBLESHOOTING (CONT.)
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Window keeps getting sooty. Unit needs more primary air.
1. Blocked primary air port. 1. Check primary air assembly. Over a period of time dust, lint, pet hair, etc. can plug primary air hole. Clean out.
2. Flame impingement on logs or 2. Reposition logs or adjust flame.
elsewhere.
3. Logs too close to or touching glass. 3. Move logs to allow at least 3/8" clearance from logs to glass.
4. Valve and burner over-fired. 4. Check the amount of flow with monometer, and adjust regulator if necessary.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Dirty window. (White on window). Initial burn off of paint and sealants 1. Clean window using AJAX or
used to produce unit. COMET, and paper towel.
2. Dissolve powder AJAX or powder COMET in water on window. Clean in small circular motions. Rinse thoroughly and reinstall in unit. DO NOT USE ANY LIQUID CLEANERS ON WINDOW. It will burn black on window when reinstalled.
NOTE: Windows are made of neo (pyro) ceramic, NOT glass. Because of this, the will handle temperatures in excess of 1,200 degrees Fahrenheit constant temperature. The window only reaches between 500-600 degrees Fahrenheit. Because of this it is almost impossible to bake something into the window. Most things will, with a little effort, some off if you follow these directions.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Circulating fan speed does not vary. Variable speed rheostat defective. Replace rheostat. NOTE: Only replace rheostat with a rheostat supplied b y United States Stov e Company. Light dimmer switches or incorrect rheostats
will burn out the fan motor. This will void the warranty of the fan.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Fan makes humming sound, but won't 1. Rheostat needs adjustment. 1. Adjust variable speed control. come on. 2. Fan imellers dirty. 2. Clean fan.
3. Fan defective. 3. Replace fan.
NOTE: Make sure the f an plug-in cord is not nic ked b y decorativ e trim kits. This could cause the fan to short out and also damage the gas valve.
PROBLEM: POSSIBLE CAUSES: REMEDIES:
Fireplace not venting. 1. Venting blocked. 1. Remove blockage.
2. Improper venting installation. 2. Check all venting connections for proper fit.
16
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 17
TURNING GAS OFF TO APPLIANCE
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by a piezo ignitor. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance areas for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
3. Push in gas control knob slightly and turn clockwise to "OFF". Do not force.
•If you cannot reach your gas supplier, call the fire
department. C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Set the thermostat to lowest setting.
3. Open lower door.
4. Turn off all electric power to the appliance.
5. Push in gas control knob slightly and turn clockwise to "OFF".
Gas Control Knob Shown in "OFF" Position
O
L
T
I
P
O
F
N
F
O
S
it
E
A
Piezo Button
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above this label. If you don't smell gas, go to the next step.
7. Find pilot. The pilot is between the two ceramic logs, behind the burner.
T
O
L
I
P
TP TH
TP TH
Pilot
Ceramic Logs
Burner
8. Turn knob on gas control counterclockwise to "PILOT".
9. Push in control knob all the way and hold in. Immediately light the pilot by pushing in on the piezo button. Continue to hold the control knob in for about one (1) minute after, the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
If the knob does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.
10. Turn gas control knob counterclockwise to "ON"
11. Turn on all electric power to the appliance.
12. Set thermostat to desired setting.
13. Close lower door. 851181
USSC 17
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 18
MODEL 9660 GENERATOR REPAIR PARTS
18
1
16
2
10
12
7
17
3
4
15
5
19
18
11
13
9
14
20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
8
6
21
22
USSC
Page 19
MODEL 9660 GENERATOR PARTS LIST
ITEM DESCRIPTION PART # QUANTITY
1 Control Plate Weldment 68984 1 2 Burner 89764 1 3 L.P. Burner Orifice 81185 1
* Natural Gas Burner Orifice 81184 1 4 Manifold Union 89762 1 5 1/4" OD Flex Tube 86541 1 6 3/8" OD Flex Tube 86542 1 7 Switch Bracket 24262 1 8 Rocker Switch C42373 1 9 Adaptor Fitting 81183 1
10 Control Bracket 24241 1 11 Piezo Bracket w/Screw 89760 1 12 Piezo w/ Nut 89761 1 13 Sit Control 81182 1 14 16ga. Link Chain 86318 1 FT. 15 Thermopile C43815 1 16 Sit Thermo-Couple 89759 1 17 L.P. Sit Pilot 89757 1
* Natural Gas Sit Pilot 89758 1
18 Generator Gasket 88086 1
* #8 x 1/2" Teks 83437 8
* Piezo Cable 80375 1
* Wire Assembly 80376 1
* 10-32 x 3/8 Machine Screw 83464 4
19 Top Fork Log 89771 1 20 Top Twig Log 89772 1 21 Rear Log 89770 1 22 Front Log 89769 1
* Natural Pilot Orifice 81186 1
* L.P. Pilot Orifice 81187 1
* NOT SHOWN
USSC 19
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 20
25
24
MODEL 9660 GAS FURNACE REPAIR PARTS
1
26
31
5
30
2
27
3
4
11
6
28
8
9
7
29
20
7
22
23
20
10
17
16
15
14
13
12
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
21
18
19
USSC
Page 21
MODEL 9660 GAS FURNACE PARTS LIST
ITEM DESCRIPTION PART # QUANTITY
1 Unit Top 24249 1 2 Unit Right Side 24242 1 3 Unit Left Side 24243 1 4 Unit Base 24255 1 5 Unit Back 24246 1 6 Top Grill 24261 1 7 Arched Door Frame 68986 1
Full-view Door Frame 69046 1 8 1-1/4" Flat Rope 88087 8.042Ft. 9 Glass 89763 1
10 Lower Grill 24260 1 11 Brass Door Knob 89336 1
* 10-32x1/2" Machine Screw 83115 1
* Lower Grill Hinge C18513 2 12 Firebox Bottom 24259 1 13 Firebox Divider 24250 1
* Flue Outlet 89754 1 14 Firebox Wrapper 24253 1
* Starting Collar 89756 1 15 Firebox Shield 24265 1 16 Firebox Top 24258 1 17 Latch w/ Keeper 89755 2 18 Insulation 24266 1 19 Firebox Front 24251 1 20 Inner Baffle 24279 1 21 Baffle Plate 24252 1 22 V ent Termination Assembly 68997 1 23 12" CO-AX Pipe 89765 1 24 Insulation Shield 24269 1 25 Top Insulation 24270 1 26 Air Deflector 24280 1 27 Left Side Trim 89748 1 28 Top Trim 89749 1 29 Right Side Trim 89747 1 30 Side Standoff (2xLeft side, 2xRight side) 24278 4 31 Rear Standoff 24283 2
* Vent Standoff 24272 4
* NOT SHOWN
USSC 21
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 22
OPTIONAL KITS AVAILABLE
MODEL: BDK60
BRASS DOOR TRIM KIT
SKYTECH
NO
R E M O T E
OFF
INDICATOR
ON OFF
SKYTECH
1001
MODEL: RCK60
REMOTE CONTROL KIT
SKYTECH
MODEL: B60 BLOWER KIT
MODEL: WSK60
WALL SWITCH KIT
REMOTE
2110 32 c
50
60 70 80 90
2110 32 c
50
60 7080 90
MODEL: WTK60
WALL THERMOSTAT KIT
MODEL: FVK60
FULL-VIEW DOOR KIT
22
REFRACTORY CERAMIC BRICK KIT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
MODEL: CBK60
USSC
Page 23
WIRING DIAGRAM FOR OPTIONAL (MODEL #B60) BLOWER KIT
WHITE (Neutral)
BLACK (Hot)
GREEN (Ground)
2x4 BOX
1/4" MALE INS.
ATTACH GROUND TO SIDE OF UNIT WITH SCREW INCLUDED
80377
THERMO DISC
80378
1/4" FEMALE INS.
1/4" MALE INS.
WIRING DIAGRAM FOR GENERATOR ASSEMBLY
GREEN
RHEOSTAT
BLACK
1/4" FEMALE INS.
BLACK
WHITE
80377
WHITE
1/4" MALE INS.
BLOWER
80378
TERMINALS
USSC 23
THERMOPILE
CONTROL
WIRING
ROCKER SWITCH
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 24
WIRING GUIDE FOR 9660
The following Wiring Guide is to help assist in the wiring of any combination of the Optional Kit listed below:
RCK60 - REMOTE CONTROL KIT WSK60 - WALL SWITCH KIT WTK60 - WALL THERMOSTAT KIT
IMPORTANT: Before ordering or installing any to the available kits, remember the following...
1) Not all Optional Kits will work together. Example: The (RCK60) Remote Control Kit, the (WSK60) Wall Switch Kit, and the (WTK60) Wall Thermostat Kit cannot be used at the time.
2) When using any of the three Optional Kits listed above, the Rocker Switch on the unit must be set to "OFF".
3) If you choose to use any combination of the above Optional Kits, only one of those kits can be used at a time. Example: If you have the Optional Remote Control Kit and the Optional Wall Switch Kit, operation of the unit must be controlled by one or the other. If you want to use the remote control, simply turn the Wall Switch to "OFF".
STANDARD WIRING FROM FACTORY:
CONTROL VALVE
O
L
T
I
P
O
L
I
T
P
O
F
F
N
O
S
it
TP TH
E
A
TP TH
ROCKER
SWITCH
WIRING OF THE RCK60 - REMOTE CONTROL KIT:
CONTROL VALVE
O
L
I
T
P
O
F
F
N
O
S
it
E
A
WIRING WITH THE WTK60 - WALL THERMOSTAT KIT:
CONTROL VALVE
O
L
I
T
P
O
F
F
N
O
S
it
E
A
24
O
L
T
I
P
TP TH
TP TH
PIGGYBACK
DISCONNECT
WALL
THERMOSTAT
O
L
T
I
P
TP TH
TP TH
PIGGYBACK
DISCONNECT
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
REMOTE CONTROL
SENSOR
ROCKER
SWITCH
2110 32 c
50
60 70 80 90
2110 32 c
50
60 7080 90
ROCKER SWITCH
Remember the Rocker Switch must be turned to "OFF" while using the Remote Control.
Remember the Rocker Switch must be turned to "OFF" while using the Wall Thermostat.
USSC
Page 25
WIRING WITH THE WSK60 - WALL SWITCH KIT:
Remember the Rocker Switch must be turned to "OFF" while using the Wall Switch.
CONTROL VALVE
O
L
I
P
O
L
I
T
P
O
F
F
N
O
S
it
E
A
T
PIGGYBACK
DISCONNECT
TP TH
TP TH
WALL
SWITCH
ROCKER
SWITCH
WIRING WITH THE WTK60 - WALL THERMOSTAT KIT AND
THE RCK60 - REMOTE CONTROL KIT:
Note: When combining these Optional kits, only one kit can be used at a time. Example: If you want to control the operation of this unit with the Remote Control then you must turn the Wall Thermostat "OFF". When trying to use two Optional kits at once, one will always override the other.
PIGGYBACK
DISCONNECT
O
L
T
I
P
TP TH
TP TH
REMOTE CONTROL
SENSOR
ROCKER
SWITCH
50
60 70 80 90
50
2110 32 c
2110 32 c
60 70 80 90
WALL
THERMOSTAT
CONTROL VALVE
O
L
I
T
P
F
O
F
N
O
S
it
E
A
WIRING WITH THE WSK60 - WALL SWITCH KIT AND
THE RCK60 - REMOTE CONTROL KIT:
Note: When combining these Optional kits you must remember that only one of them can be used at a time. Example: If you want to control the operation of this unit with the Remote Control then you must turn the W all Switch "OFF". When trying to use two Optional kits at once, one will always override the other.
PIGGYBACK
DISCONNECT
WALL
SWITCH
CONTROL VALVE
O
L
I
P
O
L
I
T
P
F
O
F
N
O
S
it
E
A
T
TP TH
TP TH
REMOTE CONTROL
SENSOR
ROCKER
SWITCH
For further information, contact our Customer Service Department at United States Stove Compan y, 227 Industrial Park Road, P.O. Box 151, South Pittsburg, Tn. 37380. (423)837-2100
USSC 25
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 26
NOTES
26
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
USSC
Page 27
NOTES
USSC 27
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE
Page 28
HOW TO ORDER REPAIR PARTS
THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR 9660 GRAVITY TYPE VENTED WALL FURNACE, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY.
KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.
WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST:
T
I
N
U
U
E
D
S
C
O
S
T
M
A
1. THE PART NUMBER
2. THE PART DESCRIPTION
3. THE MODEL NUMBER: 9660
4. THE SERIAL NUMBER: ____________________
T
E
S
S
T
S
N
A
P
C
Y
O
V
E
UNITED STATES STOVE COMPANY
227 INDUSTRIAL PARK ROAD
PO BOX 151
SOUTH PITTSBURG, TN 37380
(423) 837-2100