CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ
ALL SECTIONS OF THIS INSTRUCTION MANUAL
IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY
1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
2. Before each use, remove the spray tool from the hose, and check to make sure the
spray nozzles are securely tightened to the spray tool. A loose nozzle could fl y off during use.
3. Keep machine from rain and snow, extremes in temperatures, and store in a heated location. Use the machine indoors. Do not use outdoors.
4. Never allow the spray to remain xed in one spot.
5. Use approved chemicals only. NO SOLVENTS.
6. Wear gloves or use rags when removing quick disconnects to prevent burns.
7. Never use water above 130º F/54º C in the solution tank.
8. Never use the machine without the pre- lter bag installed.
56041959
3-2010
IMPORTANT SAFETY INSTRUCTIONS:
This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offi ces other than normal residential housekeeping purposes.
When using any electrical appliance, basic precautions should always be followed, including the following:
NOTE: Read all instructions before using this machine.
WARNING!
To reduce the risk of fi re, electric shock, or injury:
Before each use, remove the spray tool from the hose, and check to make sure the spray nozzles are securely tightened to the spray tool. A loose nozzle could fl y off during use.
Never use solvents.
Do not leave the machine unattended when it is plugged in. Unplug the unit from the outlet when
not in use, and before servicing.
To avoid electric shock, do not expose to rain or snow. Store, and use, indoors.
Do not allow the machine to be used as a toy. Close attention is necessary when used near
children.
Use only as described in this manual. Use only the manufacturer’s recommended attachments.
Never add water over 130 °F/54 °C to the solution tank.
If the machine is not working as it should, has been dropped, damaged, left outdoors, or dropped
into water, return it to a service center.
Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated surfaces. To unplug, grasp the plug, not the cord.
Do not handle the plug, the cord, or the machine with wet hands.
Extension cords must be 12/3 and no longer than 50 feet.
Do not use with a damaged cord or cord end. If the cord or unplug becomes damaged have it
repaired immediately by an authorized service center.
Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air fl ow.
Keep loose clothing, hair, ngers, and all parts of body away from openings and moving parts.
Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes,
or any health endangering dusts. Do not use the machine to pick up fl ammable or combustible liquids such as gasoline or use it in areas where they may be present.
Turn off all controls before unplugging.
Use extra care when cleaning on stairs.
Connect to a properly grounded outlet only.
Liquid ejected at the spray nozzle could be dangerous as a result of its temperature, pressure, or
chemical content. Use caution.
Always read chemical MSDS sheets before use.
INSPECTION:
Carefully unpack and inspect your KING COBRA-1200 PRO for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier.
You should notify the carrier immediately if you notice damage to the box or to the machine or parts.
CLEANING SOLUTIONS:
Select a proper pre-spray for the surface to be cleaned, and apply the pre-spray. Use a neutral pH rinse or detergent (6 to 10 pH) in the King Cobra to prevent premature wear of the pumps, seals, and other components. Damage caused by the use of improper or strong chemicals is not covered by warranty. Powdered chemicals are not recommended.
MAINTENANCE:
For optimum performance, fl ush the machine with clear water at the end of each working day. Once a month, minimum, run a fl ushing compound through the machine to break up any mineral or chemical build-up that may have formed. The vacuum motor, pump motors, and the pumps do not require any scheduled maintenance; however, the motors may require replacement brushes after 1000 - 1500 hours, and the high pressure pumps and unloader valves may require rebuild kits after 500 -1000 hours (refer to machine part list for numbers). Clean the body with an all purpose detergent, and protect it with an automobile interior polish. Lubricate the wheels, castors, and quick disconnects with an all purpose silicone spray.
Record the serial number and model of your new extractor here:
(and be sure to register your purchase to activate your warranty)
Serial Number: __________________ Model: KING COBRA-1200 PRO___
Purchase Date:_____________ Write the name and phone number of your distributor:
KNOW YOUR MACHINE
Lid, Recovery Tank
Put Pre-fi lter
bag in
here
Hoses
Latch
Solution Tank
500 psi
Pressure
Adjust
Knob
Vacuum
Hose
Connection
Wand Holder
Switches
Recovery Tank
1200 PSI Quick Disconnect
Auto-fi ll Hose Connector
Wheel
Base Compartment
500 psi Gauge
1200 psi Gauge
Recovery Tank Dump Hose
connection
Power
Cord
Receptacle
Quick Disconnect
Wand Holder
Recovery Tank
Dump
hose
500 psi
Vacuum Hose --
connect to tool
Lid, Recovery Tank
Vacuum Hose Connection
Auto-Dump
Pump
Power Prime
Pedal
Castor, with brake