US Motors UL Listed for Fire Pump Applications Catalog Page

Special Application Three Phase, Open Drip Proof (ODP)
®†
Listed for Fire Pump Applications
UL
BRAKEMOTORS
APPLICATIONS:
For re pump applications per NFPA®† 20 where contaminants are minimal.
FE ATURES:
SINGLE PHASE
• Class F Insulation, Class B Rise At Service Factor
GENERAL PURPOSE
• Rolled Steel Frame 250-320, Cast Iron Frame 360-440
• Aluminum End Shields 250, Cast Iron End Shields 280-440
• Premasked Mylar Nameplate 250-320, Stainless Steel 360-440 Frame
• 40°C Ambient, NEMA®† Design B Performance On 60 Hertz Sine Wave Power
HVACWASHDOWNAGRICULTURE
• Regreasable Bearings 180 Frame & Larger
• Double Shielded Bearings 250 -400, Open On 440 Frame
HP RPM Voltage Frame
3600 200/400 254T FF20E1X DS-3FFP 1.15 22.6 150 90.2 54/26.9
20
3600 208-230/460 254T FF20E1A DS-3FFP 1.15 22.6 162 90.2 54-47/23.6 1800 200/400 256T FF20E2X DS-3FFP 1.15 23.2 160 91.0 58/29.1 17 1800 208-230/460 256T FF20E2A DS-3FFP 1.15 23.2 160 91.0 54-50/24.9 3600 200/400 256T FF25E1X DS-3FFP 1.15 23.2 160 91.0 67/33
25
3600 208-230/460 256T FF25E1A DS-3FFP 1.15 23.2 172 91.0 66-58/29 1800 200/400 284TS FF25E2XS DS-3FFP 1.15 23.5 300 91.7 70/35 1800 208-230/460 284TS FF25E2AS DS-3FFP 1.15 23.5 300 92.4 66-60/30 1800 575 284TS FF25E2GS DS-3FFP 1.15 23.5 312 91.7 24.4 38 3600 200/400 284TS FF30E1XS DS-3FFP 1.15 23.5 300 92.4 78/39
30
3600 208-230/460 284TS FF30E1AS DS-3FFP 1.15 23.5 312 91.0 80-70/35 1800 200/400 286TS FF30E2XS DS-3FFP 1.15 23.5 350 93.6 79/40
MOTORS
COMMERCIAL PUMP
1800 208-230/460 286TS FF30E2AS DS-3FFP 1.15 23.5 337 92.4 78-71/35 3600 200/400 286TS FF40E1XS DS-3FFP 1.15 23.5 350 91.7 106/53
40
3600 230/460 286TS FF40E1ES DS-3FFP 1.15 23.5 325 93.0 90/45 3600 575 286TS FF40E1GS DS-3FFP 1.15 23.5 325 93.0 36 38 1800 200/400 324TS FF40E2XS DS-3FFP 1.15 25.8 385 93.6 105/53 02 1800 208-230/460 324TS FF40E2AS DS-3FFP 1.15 25.8 416 93.6 102-91/46
PUMP MOTORS
CLOSE COUPLED
1800 575 324TS FF40E2GS DS-3FFP 1.15 25.8 416 93.0 37 38 3600 200/400 324TS FF50E1XS DS-3FFP 1.15 25.8 385 93.0 134/67 02
50
3600 208-230/460 324TS FF50E1AS DS-3FFP 1.15 25.8 416 92.4 129-116/58 3600 575 324TS FF50E1GS DS-3FFP 1.15 25.8 416 92.4 46 38 1800 200/400 326TS FF50E2XS DS-3FFP 1.15 25.8 415 93.6 131/65 02
MOTORS
1800 208-230/460 326TS FF50E2AS DS-3FFP 1.15 25.8 446 93.6 128-114/57 1800 575 326TS FF50E2GS DS-3FFP 1.15 25.8 446 93.0 46 38 3600 200/400 326TS FF60E1XS DS-3FFP 1.15 25.8 415 93.0 156/78 02
60
3600 230/460 326TS FF60E1BS DS-3FFP 1.15 25.8 447 93.0 155-136/68 3600 575 326TS FF60E1GS DS-3FFP 1.15 25.8 446 93.0 54 38 1800 200/400 364TS FF60E2XS DS-3FFP 1.15 26.6 580 94.1 159/80
MOTORS
POOL & SPA
1800 230/460 364TS FF60E2BS DS-3FFP 1.15 26.6 611 93.6 150/75 1800 575 364TS FF60E2GS DS-3FFP 1.15 26.6 580 94.1 55 38 3600 200/400 364TS FF75E1XS DS-3FFP 1.15 26.6 580 93.0 200/100
75
3600 230/460 364TS FF75E1ES 3600 575 364TS FF75E1GS DS-3FFP 1.15 26.6 580 94.1 68 38 1800 200/400 365TS FF75E2XS DS-3FFP 1.15 27.6 600 94.1 199/99 1800 230/460 365TS FF75E2BS DS-3FFP 1.15 27.6 631 94.1 172/86
WATER PUMP
RESIDENTIAL
1800 575 365TS FF75E2GS DS-3FFP 1.15 27.6 600 95.0 70 38
Catalog Number
• Lifting Provisions 210 Frame & Larger
• Suitable For Wye-Delta Start 250 Frame & Larger
• Dual Voltage Ratings Suitable For Part Winding Start (PWS) On Low Voltage
• 230/460 & 575 Volt Ratings Comply With NRCan Standards
• 230/460V Ratings Dual Plated For 190/380V 50 Hertz, Next Lower Horsepower
• Oversized Connection Diagram, "CE" Mark On Nameplate
Discount
Symbol
DS-3FFP 1.15 26.6 6
SF "C" Dim.
(inches)
Ship Wt.
(lbs)
NEMA
Nom. Eff.
11 94.1 171/85
Full Load
Amps Notes
R, D,
FD, FR
Note 02 Suitable for Wye-Delta start on voltages shown Note 17 Twelve leads for across-the-line or wye-delta start on either voltage, part winding start on lower voltage Note 38 Q-6 Leads for across-the-line or wye-delta start
GATE & DOOR
ELEVATOR AND
223 usmotors
Special Application Three Phase, Open Drip Proof (ODP)
®†
Listed for Fire Pump Applications
UL
BRAKEMOTORS
(continued)
FD, FR
HP RPM Voltage Frame
3600 200/400 365TS FF100E1XS DS-3FFP 1.15 28.0 600 93.0 260/130
100
Number
Catalog
Discount
Symbol
SF "C" Dim.
(inches)
Ship Wt.
(lbs)
NEMA
Nom. Eff.
Full Load
Amps Notes
3600 230/460 365TS FF100E1BS DS-3FFP 1.15 28.0 631 93.6 225/112 3600 575 365TS FF100E1GS DS-3FFP 1.15 28.0 631 94.1 89 38 1800 200/400 404TS FF100E2XS DS-3FFP 1.15 29.5 750 94.5 261/130 47 1800 230/460 404TS FF100E2BS DS-3FFP 1.15 29.5 885 94.5 226/113 47 1800 575 404TS FF100E2GS DS-3FFP 1.15 29.5 750 95.0 90 38 3600 460 404TS FF125E1CS DS-3FFP 1.15 29.5 815 94.1 137 47
125
3600 575 404TS FF125E1GS DS-3FFP 1.15 29.5 750 94.1 110 38 1800 460 405TS FF125E2CS DS-3FFP 1.15 31.1 813 95.0 140 47 1800 575 405TS FF125E2GS DS-3FFP 1.15 31.1 813 95.0 112 38 3600 460 405TS FF150E1CS DS-3FFP 1.15 31.0 763 93.6 165 47
150
3600 575 405TS FF150E1GS DS-3FFP 1.15 31.0 813 93.6 132 38 1800 460 444TS FF150E2CS DS-3FFP 1.15 36.1 1100 95.0 171 47 1800 575 444TS FF150E2GS DS-3FFP 1.15 36.1 1100 95.0 136 38 3600 460 444TS FF200E1CS DS-3FFP 1.15 36.1 1100 94.5 225 47
200
3600 575 444TS FF200E1GS DS-3FFP 1.15 36.1 1100 94.5 180 38 1800 460 445TS FF200E2CS DS-3FFP 1.15 36.1 1200 95.0 230 47 1800 575 445TS FF200E2GS DS-3FFP 1.15 36.1 1200 95.0 189 38 3600 460 445TS FF250E1FS DS-3FFP 1.15 36.1 1200 94.5 276 38
250
1800 460 445TS FF250E2FS DS-3FFP 1.15 36.1 1200 95.4 281 47 1800 575 445TS FF250E2GS DS-3FFP 1.15 36.1 1200 95.4 225 47
300 3600 460 445TS FF300E1FS DS-3FFP 1.15 36.1 1200 95.0 326 47
R, D,
GENERAL PURPOSE
SINGLE PHASE
AGRICULTUREWASHDOWNHVAC
COMMERCIAL PUMP
MOTORS
Note 38 Q-6 Leads for across-the-line or wye-delta start Note 47 Q-12 leads for across-the-line, wye-delta or part winding start
CLOSE COUPLED
PUMP MOTORS
MOTORS
POOL & SPA
MOTORS
RESIDENTIAL
WATER PUMP
GATE & DOOR
ELEVATOR
usmotors 224