US Motors Stock World Motor Cooling Tower Duty Three Phase Catalog Page

Stock World Motor Cooling Tower Duty Three Phase, TEAO & TEFC
Premium E󰀩cient, Inverter Duty 10:1 (6-60 Hz) Speed Range Variable Torque
GENERAL PURPOSE
UNIMOUNT®
APPLICATIONS:
For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity.
FE ATUR E S:
• INVERTER GRADE® Motors with Insulation that Exceeds the NEMA®† MG -1 Part 31 Standard
• Double Dip & Bake, 100% Solids, Polyester Insulation on Windings
• Class F Insulation, 40°C Ambient
• Cast Iron Frame & Outlet Box
• Cast Iron Bearing Caps
• Double Sealed bearings
• Double Drilled Feet to Accommodate Mounting Flexibility
• Sealed Bracket-to-Frame Registers & Leads
ORDERING INFORMATION:
Options below available from Southaven Distribution Center ONLY
Totally Enclosed Air Over (TEAO)
• Stainless Steel Nameplate & Zinc Plated Hardware
• 1.15 Service Factor
• Rotor Balance better than 0.08 in/sec Inverter Compatible: Exceeds NEMA MG-1 Part 31 (10:1 Variable Torque)
• NEMA®† Design B Performance on 60 Hertz Sine Wave Power
• Meets IEC 3 4-5 Classication IP55
• Space Heater (115v)
• Includes CORRO-DUTY® Motor Paint and Rotor Treatment
• Refer to Page vii for Suitability of IHP Motors on Variable Frequency Drives
• Refer to Page 73 for Minimum Air Velocity Requirements
GENERAL PURPOSE
STEEL EDGE
TM
GENERAL PURPOSE
®†
GENERAL PURPOSE
CORRO-DUT Y
®
GENERAL PURPOSE
841 PLUS
®
GENERAL PURPOSE
OPEN DRIPPROOF
HP RPM Volts Frame
New Stock
Cat#
Assembly
Position
Discount
Symbol
SF
"C" Dim.
(inches)
Ship Wt.
(lbs)
NEMA
Nom. Eff.
Full Load
Amps
2 1200 230/460 184T CVW2V3B6 W6 DS-3CTSW 1.15 13.6 130 88 .5 6.2/3.1
1800 230/460 182T CVW3V2B6 W6 DS-3CTSW 1.15 13.6 130 89 .5 7.7/3.9
3
1200 230/460 213T CVW3V3B6 W6 DS-3CTSW 1.15 17.1 200 90 .2 8.6/4.3 1800 200 184T CVW5V2H6 W6 DS-3CTSW 1.15 13.6 130 89 .5 14.5
5
1800 230/460 184T CVW5V2B6 W6 DS-3CTSW 1.15 13.6 130 89 .5 12.7/6.3 1200 230/460 215T CVW5V3B6 W6 DS-3CTSW 1.15 17.1 200 90 .2 14. 2/ 7.1
7 1/2
1800 200 213T CVW7V2H6 W6 DS-3CTSW 1.15 17.1 200 91 .7 21.9 1800 230/460 213T CVW7V2B6 W6 DS-3CTSW 1.15 17.1 200 91 .7 19.2/9.6 1200 230/460 254T CVW7V3B6 W6 DS-3CTSW 1.15 22.3 325 91 .0 18.8/9.4 1800 200 215T CVW10V2H6 W6 DS-3CTSW
10
1.15
17.1 200 91 .7 29.3 1800 230/460 215T CVW10V2B6 W6 DS-3CTSW 1.15 17.1 200 91 .7 25.7/12.8 1200 230/460 256T CVW10V3B6 W6 DS-3CTSW 1.15 22.3 325 91 .7 25.1/12.5 1800 200 254T CVW15V2H6 W6 DS-3CTSW 1.15 22.3 325 92 .4 41
15
1800 230/460 254T CVW15V2B6 W6 DS-3CTSW 1.15 22.3 325 92 .4 36/18 1200 230/460 284T CVW15V3B6 W6 DS-3CTSW 1.15 24.8 380 91 .7 36/18.2 1800 200 256T CVW20V2H6 W6 DS-3CTSW 1.15 22.3 325 93 .0 54
20
1800 230/460 256T CVW20V2B6 W6 DS-3CTSW 1.15 22.3 325 93 .0 47/23.7 1200 230/460 286T CVW20V3B6 W6 DS-3CTSW 1.15 24.8 410 91 .7 48/24 1800 230/460 284T CVW25V2B6 W6 DS-3CTSW 1.15 24.8 380 93 .6 58/29.2
25
1200 230/460 324T CVW25V3B6 W6 DS-3CTSW 1.15 27.5 605 93 .0 59/29.3 1800 230/460 286T CVW30V2B6 W6 DS-3CTSW 1.15 24.8 410 93 .6 69/34
30
1200 230/460 326T CVW30V3B6 1800 230/460 324T CVW40V2B6 W6 DS-3CTSW 1.15 27.5 605 94 .1 92/46
40
W6
DS-3CTSW 1.15 27.5 605 93 .0 70/35
1200 230/460 364T CVW40V3B6 W6 DS-3CTSW 1.15 29.6 740 94 .1 94/47 1800 230/460 326T CVW50V2B6 W6 DS-3CTSW 1.15 27.5 605 94 .5 112/ 56
50
1200 230/460 365T CVW50V3B6 W6 DS-3CTSW 1.15 29.6 910 94 .1 117/5 9 1800 230/460 364T CVW60V2B6 W6 DS-3CTSW 1.15 29.6 740 95 .0 137/68
60
1200 230/460 404T CVW60V3B6 W6 DS-3CTSW 1.15 33.8 960 94 .5 140/70 1800 230/460 365T CVW75V2B6 W6 DS-3CTSW 1.15 29.6 910 95 .4 170/8 5
75
1200 230/460 405T CVW75V3B6 W6 DS-3CTSW 1.15 33.8 990 94 .5 178/89
100 1800 230/460 405T CVW100V2B6 W6 DS-3CTSW 1.15 33.8 1000 95 .4 229/115
Notes
HAZARDOUS LOCATION
GENERAL PURPOSE
GENERAL PURPOSE
COOLING TOWER
HAZARDOUS
LOCATION
MOTORS
C-FACE
usmotors 69B
VARIABLE SPEED
MOTORS AND DRIVES
Stock World Motor Cooling Tower Duty Three Phase, TEAO & TEFC
UNIMOUNT®
Premium E󰀩cient, Inverter Duty 10:1 (6-60 Hz) Speed Range Variable Torque
GENERAL PURPOSE
(continued)
TM
Totally Enclosed Fan Cooled (TEFC)
* W6 & W7 mounting not available on Totally Enclosed Fan Cooled (TEFC) Motors.
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
STEEL EDGE
HP RPM Volts Frame
1800 230/460 145T CW2V2E2 F2 DS-3CTSW 1 .15 13.5 80 86 .5 5.3/2.7
2
1200 230/460 184T CW2V3E2 F2 DS-3CTSW 1 .15 16.3 110 88 .5 6.2/3.1 1800 200 182T CW3V2H2 F2 DS-3CTSW 1 .15 16.3 100 89 .5 8.8
3
1800 230/460 182T CW3V2E2 F2 DS-3CTSW 1 .15 16.3 100 89 .5 7.8/3.9 1800 575 182T CW3V2G2 F2 DS-3CTSW 1 .15 16.3 100 89 .5 3.1
®
1200 230/460 213T CW3V3E2 F2 DS-3CTSW 1 .15 19.6 170 90 .2 8.6/4.3 1800 200 184T CW5V2H2 F2 DS-3CTSW 1 .15 16.3 110 89 .5 14. 5
5
1800 230/460 184T CW5V2E2 F2 DS-3CTSW 1 .15 16.3 110 89 .5 12.7/6.3 1800 575 184T CW5V2G2 F2 DS-3CTSW 1 .15 16.3 11 0 89 .5 5.1
CORRO-DUT Y
7 1/2
1200 230/460 215T CW5V3E2 F2 DS-3CTSW 1 .15 19.6 1800 200 213T CW7V2H2 F2 DS-3CTSW 1 .15 19.6 170 91 .7 22 1800 230/460 213T CW7V2E2 F2 DS-3CTSW 1 .15 19.6 170 91 .0 19.1/9.6
®
1800 575 213T CW7V2G2 F2 DS-3CTSW 1 .15 19.6 170 91 .7 7. 8 1200 230/460 254T CW7V3E2 F2 DS-3CTSW 1 .15 24.9 250 91 .0 18.8/9.4 1800 200 215T CW10V2H2 F2 DS-3CTSW 1 .15 19.6 180 91 .7 29.3
841 PLUS
10
1800 230/460 215T CW10V2E2 F2 DS-3CTSW 1 .15 19.6 180 91 .7 25.7/12.8 1800 575 215T CW10V2G2 F2 DS-3CTSW 1 .15 19.6 180 91 .7 10.3 1200 230/460 256T CW10V3E2 F2 DS-3CTSW 1 .15 24.9 280 91 .7 24.9/12.4 1800 200 254T CW15V2H2 F2 DS-3CTSW 1 .15 24.9 270 92 .4 41
15
1800 230/460 254T CW15V2E2 F2 DS-3CTSW 1 .15 24.9 270 92 .4 36/18 1800 575 254T CW15V2G2 F2 DS-3CTSW 1 .15 24.9 270 92 .4 14.5
OPEN DRIPPROOF
1800 200 256T CW20V2H2 F2 DS-3CTSW
20
1800 230/460 256T CW20V2E2 F2 DS-3CTSW 1 .15 24.9 300 93 .0 47/23.7 1800 575 256T CW20V2G2 F2 DS-3CTSW 1 .15 24.9 300 93 .0 18.9 1800 200 284T CW25V2H2 F2 DS-3CTSW 1 .15 27.5 385 93 .6 67
25
1800 230/460 284T CW25V2E2 F2 DS-3CTSW 1 .15 27.5 380 93 .6 58/29.2 1800 575 284T CW25V2G2 F2 DS-3CTSW 1 .15 27.5 380 93 .6 23.3 1800 230/460 286T CW30V2E2 F2 DS-3CTSW 1 .15 27.5 410 93 .6 70/35
HAZARDOUS LOCATION
30
1800 575 286T CW30V2G2 F2 DS-3CTSW 1 .15 27.5 410 93 .6 28.1 1800 230/460 324T CW40V2E2 F2 DS-3CTSW 1 .15 30.1 600 94 .1 92/46
40
1800 575 324T CW40V2G2 F2 DS-3CTSW 1 .15 30.1 600 9 4 .1 37 1800 230/460 326T CW50V2E2 F2 DS-3CTSW 1 .15 30.1 625 94 .5 112/5 6
50
1800 575 326T CW50V2G2 F2 DS-3CTSW 1 .15 30.1 625 94 .5 45
1800 230/460 364T
60
1800 575 364T CW60V2G2 F2 DS-3CTSW 1 .15 32.3 910 95 .0 55
75 1800 230/460 365T CW75V2E2 F2 DS-3CTSW 1 .15 32.3 910 95 .4 170/85
New Stock
Cat#
Assembly
Position
Discount
Symbol
SF
"C" Dim.
(inches)
Ship Wt.
(lbs)
NEMA
Nom. Eff.
180
1 .15
24.9 300 93 .0 55
CW60V2E2 F2 DS-3CTSW 1 .15 32.3 740 95 .0 137/6 8
Full Load
Amps
90 .2 14.2/7.1
Notes
COOLING TOWER
HAZARDOUS
C-FACE
Minimum Air Velocity Required for TEAO Models
Horsepower
Velocity (FPM)
4 Pole
2 1000 580
LOCATION
3 1000 600 5 1054 700
7.5 1023 650 10 975 600 15 1500 650 20 1700 850
MOTORS
*Note: Use 1/2 of these velocities for 8 Pole (900 RPM). Use the above velocities for 50 Hz motors
Velocity (FPM)
6 Pole
Horsepower
Velocity (FPM)
25 1500 950 30 1600 1000 40 1700 1100 50 1800 1150 60 1800 1150 75 2000 1300
100 2000 1300
4 Pole
Velocity (FPM)
6 Pole
(Customer to make adjustments for lower motor speed in order to maintain fan speed).
Asset Condition Monitoring Solution to visualize* health and performance data
MOTORS AND DRIVES
VARIABLE SPEED
70 usmotors
Refer to Page 109
Loading...