Permanent Split Capacitor Ventilation Direct Drive Blower
5.0" & 5.6" Diameter, Open Air Over
BRAKEMOTORS
APPLICATIONS:
Designed to meet manufacturer’s requirements for direct drive ventilation units.
SINGLE PHASE
FE ATURES:
GENERAL PURPOSE
• Capacitor Included And Mounted On PSC Models
• Automatic Reset Thermal Overload Protector
• Continuous Duty
• Ball Bearings Unless Noted
HVACWASHDOWNAGRICULTURE
HPRPM/
Spd. Voltage
1/12 850 115 4740 1.7 48YZ PSC 3.25 .500 CW 5.81 9.06 10
1/8 1600 115 1357 1.7 48Y PSC 3.00 .500 CCW REV 4.06 7.0 6 8
1650 115 4742 2.7 42YZ PSC 3.25 .500 CW 5.81 9.06 9
1/6
110 0 115 1146 2.2 48YZ PSC 3.00 .500 CCW REV 3.81 7.3 6 12
1/4 1015 115 4153 4.5 48 PSC 1.5 .500 CW - 10.00 18
1650 115 4745 4.0 48YZ PSC 3.25 .500 CW REV 6.06 9.31 14
1/3
110 0 115 474 6 4.4 48YZ PSC 3.25 .625 CW 5.81 9.06 17
MOTORS
COMMERCIAL PUMP
1075 115 1145 4.9 48YZ PSC 3.00 .500 CCW REV 4.81 7.81 15
110 0 115/230 4749 6. 2/3.1 48YZ PSC 3.30 .625 CW 6.60 9.90 18
1/2
1650 115/230 4748 8.0/4.0 48YZ PSC 3.25 .625 CW REV 6.31 9.56 22
3/4 1100 115/230 4750 10.0/5.0 48YZ PSC 3.25 .625 CW 6.56 9.81 18
Catalog
Number Amps
• 40°C Ambient Rated
• 1.0 Service Factor
• Discount Symbol: DS-3HAC
NEMA
Frame
Motor
Typ e
Shaft NShaft URotation
Lead End
C
N
U
Length XITot al CShip
Wt. Notes
PUMP MOTORS
CLOSE COUPLED
MOTORS
FIRE PUM P
MOTORS
POOL & SPA
WATER PUMP
RESIDENTIAL
GATE & DOOR
ELEVATOR AND