General Purpose Three Phase, Open Drip Proof (ODP) Resilient Base
®†
UNIMOUNT®
NEMA
GENERAL PURPOSE
APPLICATIONS:
For use on pumps, fans, compressors, material handling and other general purpose applications where contaminants are minimal.
C-FACE
FE ATUR E S:
GENERAL PURPOSE
• Rolled Steel Frame
• Aluminum End Shields
• 40°C Ambient
• F1 Assembly Position
• Resilient Base
HOSTILE DUTY
GENERAL PURPOSE
®
Premium Ecient
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
GENERAL PURPOSE
CORRO-DUT Y
HP RPM
Voltage Frame
Catalog
Number
Discount
Symbol SF
"C" Dim.
(inches)
Ship Wt.
(lbs)
NEMA
Nom. Eff.
Full Load
Amps
Notes
1/3 1800 208-230/460 56H D13P2AH9 DS-3F 1.35 11.8 24 73.4 1.4-1.4/0.7
®
841 PLUS
1/2 1800 208-230/460 56H D12P2AH9 DS-3F 1.25 11.8 25 78.2 1.98-1.9/.98
3/4 1800 208-230/460 56H D34P2AH9 DS-3F 1.25 12.3 26 82.2 2.8-2.7/1.4
1 1800 208-230/460 56H D1P2DH9 DS-3F 1.15 12.8 32 83.5 3.2-3.0/1.5
3600 208-230/460 56H D32PA1AH9 DS-3F 1.15 12.3 32 84.0 4.7-4.4/2.2 LA
1 1/2
3600 208-230/460 56H D32SA1AH9 DS-3F 1.15 12.8 32 82.0 4.7-4.4/ 2.2 NNP,LA
1800 208-230/460 56H D32P2AH9 DS-3F 1.15 13.3 33 86.5 5.0- 4.8/2.4
OPEN DRIPPROOF
HAZARDOUS LOCATION
AUTOMOTIVE DUTY
DUTY
COOLING TOWER
LOCATION
HAZARDOUS
C-FACE
MOTORS
Note LA Limited Availability
Note NNP Non-NEMA
MOTORS AND DRIVES
VARIABLE SPEED
59 usmotors
®†
Premium Rating