USG Geometrix User Manual

Field Cutting and Forming Panels
Geometrix
1. 1. 1.
1. 1. 1.
1.
Step 3
Score panel face between these points with a sharp utility knife and straight edge.
Step 5
Snip the side edge of the panel at the ends of each score line.
Step 6a
Bend and break off the section to be discarded. Use a straightedge to avoid deforming the panel face.
6b
Step 4a
Make a second score parallel to the first with 1to 3 between. Material between the score lines will be used to form a new side edge. The rest will be discarded.
Step 4b
Step 1
Measure grid opening.
Step 2a
Transfer dimensions to panel.
Step 2b
Page 1 of 2
Step 7
Use pliers to flatten the side edges of the remaining scored section.
Step 8
Use a hammer to finish flattening these side edges. Be careful not to mar the panel face.
Step 9a
Use a straightedge to bend up this flattened section at the score line. You may need to finish this step by hand to completely form the new side edge.
Step 9b Step 10
Mark where the new side edge extends beyond the panel perimeter.
Step 12a
Install field-cut panel.
Step 12b
Step 11
Trim away and discard this excess material.
Note:
Be especially careful when field-cutting panels that do not butt to a wall.
Note
All products described here may not be available in all geographic markets and are subject to change without notice. Consult your local sales office or representative for information.
Trademarks
The following are trademarks of USG Interiors, Inc. or a related company: G
EOMETRIX, USG.
Notice
We shall not be liable for incidental or consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with
current printed instruction or for other than intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered.
SAFETY FIRST!
Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation.
Manufactured by USG Interiors, Inc. 125 South Franklin Street Chicago, IL 60606
IC452/1-03 © 2003, USG Interiors, Inc. Printed in U.S.A.