UseTECH FlowTimer+ Operating Manual

Page 1
FlowTimer+ Hub Set
Connection center for the FlowTimer+ System
Operating manual
Page 2
usetech GmbH Tanzplatz 10 D- 55130 Mainz
Phone:
+49 6131 - 921325
Website:
www.use-tech.com
FlowTimer+ Hub Set_Manual_EN_V3 Original Operating Manual
04.03.2019
04.03.2019
usetech GmbH
This documentation including all its parts is protected by copyright. Any use or modification outside the narrow limits of copyright law without the consent of the company usetech GmbH is prohibited and punishable by law.
This applies in particular to duplications, translations, microfilming and storage in electronic systems as well as processing in these.
Page 3
Table of contents
Table of contents
Table of contents ......................................................................... 1
1 General information ............................................................. 3
1.1 Explanation of symbols ......................................................... 3
2 Technical data ...................................................................... 5
2.1 Electrical data ........................................................................ 5
2.2 Environmental and climate conditions ................................... 5
2.3 Lifetime .................................................................................. 5
3 Intended Use ........................................................................ 6
3.1 Non-approved use ................................................................. 7
4 Basic safety instructions ..................................................... 8
5 System description FlowTimer+ Hub Set ........................... 9
5.1 Content of the FlowTimer+ Hub Set ...................................... 9
5.2 FlowTimer+ Hub Plan view ................................................. 10
6 Installation .......................................................................... 11
6.1 Mounting the Hub on the Mobile phone holder ................... 11
6.2 Mounting the Hub on a pipeline .......................................... 12
6.3 Electrical connection ........................................................... 13
6.4 Cascading the FlowTimer+ Hub .......................................... 13
6.5 Potential-free alarm output .................................................. 15
6.6 Charging connection Smartphone ....................................... 16
6.7 Smartphone app .................................................................. 16
7 Operation and Function ..................................................... 17
7.1 Operating conditions ........................................................... 17
7.1.1 Normal operation ........................................................................... 17
7.1.2 Restarting the system ................................................................ .... 17
7.2 Status display ...................................................................... 17
03/19 FlowTimer+ Hub Set 1
Page 4
Table of contents
8 Troubleshooting, Maintenance ......................................... 18
8.1 No display ............................................................................ 19
8.2 Alarm signals ....................................................................... 19
8.2.1 Status display permanently red ..................................................... 19
8.3 Maintenance ........................................................................ 20
9 Packaging, Transport, Storage ......................................... 21
10 Disposal .............................................................................. 22
11 EC Declaration of Conformity ........................................... 23
03/19 FlowTimer+ Hub Set 2
Page 5
General information
NOTE
The operating instructions contain important information on safety!
Non-observance of these instructions can lead to dangerous situations.
The operating instructions must be read and understood.
DANGER
Warns of imminent danger!
Failure to do so will result in death or serious injury.
WARNING
Warns of a potentially dangerous situation!
Failure to do so could result in serious injury or death.
CAUTION
Warns of a possible hazard!
Failure to do so may result in moderate or minor injury.
NOTE
Warns of material damage!
Failure to do so may result in damage to the system or equipment.
1 General information
The operating instructions describe the entire life cycle of the system. Keep this manual in such a way that it is easily accessible to any user and available to any new owner of the system.
1.1 Explanation of symbols
03/19 FlowTimer+ Hub Set 3
Page 6
General information
indicates important additional information, tips and recommendations that are important for your safety and the proper functioning of the system.
refers to information in this operating manual or other documentation.
action steps
The defined sequence of steps makes it easier for you to use the system correctly and safely.
Result
Here you will find the result of a sequence of steps described.
03/19 FlowTimer+ Hub Set 4
Page 7
Technical data
2 Technical data
2.1 Electrical data
Input voltage: 5VDC Power consumption: average max. 0.25 W Supply connection: Micro USB socket
Output socket: USB A socket Output current USB: max. 1.5 A
Potential-free output:
Contact rating, 30VDC / 2A
I/O sockets: 4x RJ12 (6pol)
2.2 Environmental and climate conditions
Ambient temperature: +5°C-40°C Protection class: IP20 Location: only suitable for indoor use
2.3 Lifetime
The function of FlowTimer+ Hub must be checked by a qualified
technician at regular intervals (see also chapter 9.3).
03/19 FlowTimer+ Hub Set 5
Page 8
Intended Use
3 Intended Use
Please observe the notes in this operating manual as well as the operating conditions and permissible data in the data sheet so that the system functions perfectly and remains operational for a long time. In case of non-observance of these instructions as well as in case of inadmissible interventions into the system, any liability on our part is void, as is the warranty on the system and accessories!
The FlowTimer+ Hub connects several FlowTimer+ to a group, and thus generates a group alarm.
This alarm is available via a potential-free switching output (for alarm systems, Smart Home Sensor, etc.).
An external smartphone can be permanently charged via the FlowTimer+ Hub. In the event of an alarm, the FlowTimer+ Hub interrupts the charge, a suitable app on the smartphone can then, for example, send an SMS as a warning.
The FlowTimer+ Protect can be connected like a FlowTimer+ and is then activated in case of an alarm.
Any other use or use going beyond this shall be deemed improper use. The usetech GmbH is not liable for damages resulting from this. The risk is borne solely by the user.
03/19 FlowTimer+ Hub Set 6
Page 9
Intended Use
3.1 Non-approved use
Unapproved use in the sense of a foreseeable misuse shall be deemed to be improper use:
The I/O sockets of the FlowTimer+ Hub are only suitable for the
connection of FlowTimer+ products. No telephones, ISDN, other devices or adapters may be connected.
The FlowTimer+ Hub may only be operated with the
components in the set or other FlowTimer+ products, unless explicitly stated otherwise! If components of other manufacturers are used, usetech GmbH is not liable for damages and the warranty also expires.
The USB A output socket serves only as a charging socket for a
smartphone.
03/19 FlowTimer+ Hub Set 7
Page 10
Basic safety instructions
WARNING
Electrical voltage can be life-threatening.
The installation of a stationary power supply must be
carried out by a qualified electrician.
The system must be commissioned and, if necessary, adapted by a specialist. The local conditions must be observed.
4 Basic safety instructions
03/19 FlowTimer+ Hub Set 8
Page 11
System description FlowTimer+ Hub Set
1
Plug power supply 5V / 1,5A
2
FlowTimer+ Stroke
3
Mobile phone holder
4
I/O connection cable 2 m
5
Charging cable 0.3 m (Micro USB to USB A)
5 System description FlowTimer+ Hub Set
5.1 Content of the FlowTimer+ Hub Set
Fig. 5.1: Content of the FlowTimer+ Hub Set
The set also includes a Power Strip, two self-adhesive mounting sockets and two cable ties for mounting the FlowTimer+ Hub.
03/19 FlowTimer+ Hub Set 9
Page 12
System description FlowTimer+ Hub Set
6
Power supply connection (Micro USB socket)
7
I/O connection (RJ12 /6pol)
8
Status display (red/green)
9
Potential-free switching output
10
Charging socket output (USB A)
11
Nameplate
5.2 FlowTimer+ Hub Plan view
Fig. 5.2: FlowTimer+ Hub Plan view
03/19 FlowTimer+ Hub Set 10
Page 13
Installation
6 Installation
6.1 Mounting the Hub on the Mobile phone holder
Fig. 6.1: FlowTimer+ Hub mounted on mobile holder
As shown in Figure 6.1, the FlowTimer+ Hub can be glued to the
hand holder from below using the supplied Power Strip.
The plugged-in power supply unit then holds the
Mobile phone holder with hub and if required also the smartphone on the wall.
03/19 FlowTimer+ Hub Set 11
Page 14
Installation
6.2 Mounting the Hub on a pipeline
Fig. 6.2: FlowTimer+ Hub Rear view with mounting sockets
Stick the self-adhesive mounting bases (12) to the back of the
FlowTimer+ Hub as shown in Figure 6.2. Push the cable ties (13) from below through the bases and tighten them on the pipeline.
03/19 FlowTimer+ Hub Set 12
Page 15
Installation
If the I/O plug is plugged into the socket, this must cause a clicking noise. If not, please check again whether the plug is correctly engaged!
When disconnecting connections, please note to press the locking lugs of the I/O connectors!
If more than four FlowTimer+ or FlowTimer+ Protect are used, additional FlowTimer+ Hub Sets are required.
6.3 Electrical connection
Plug the power supply unit into a suitable socket and connect
the power supply unit to the power supply connection (6) of the FlowTimer+ Hub.
The status indicator (8) of the FlowTimer+ Hub must now be
green glow.
Now connect all FlowTimer+ and FlowTimer+ Protect to the I/O
sockets (7) of the FlowTimer+ Hub (2) using the I/O connection cables (4).
6.4 Cascading the FlowTimer+ Hub
Connect three I/O connectors (7) to FlowTimer+ or FlowTimer+
03/19 FlowTimer+ Hub Set 13
Protect devices using the I/O connecting cables (4) of the FlowTimer+ Hub Set.
Page 16
Installation
Remark:
Therefore only one FlowTimer+ Hub Set is required when using a total of 4 FlowTimer+ or FlowTimer+ Protect.
If more than a total of 4 FlowTimer+ or FlowTimer+ Protect devices are used, an additional FlowTimer+ Hub Set is required for every two additional FlowTimer+ or FlowTimer+ Protect devices!
Note:
Only the FlowTimer+ Hub has to be supplied with voltage by the power supply unit (1), at which an output (switching contact or charging output) is also used!
WARNING
Risk of destruction:
Never use ISDN distributors, splitters or telephone
distributors to connect FlowTimer+ devices.
Connect the remaining fourth I/O port (7) to another FlowTimer+
Hub I/O port (7).
Which I/O connection (7) is used for which device and which
sequence is irrelevant for the function.
Three more FlowTimer+ Hubs can now be connected to the
second FlowTimer+ Hub, FlowTimer+ or FlowTimer+ Protect, or two FlowTimer+ / Protect and one more FlowTimer+ / Protect and another FlowTimer+ Hub!
03/19 FlowTimer+ Hub Set 14
Page 17
Installation
WARNING
Never connect mains voltage!
The contact load capacity is 30VDC / 2A
6.5 Potential-free alarm output
Fig. 6.3: FlowTimer+ Hub Scheme Alarm Contact
The illustration above shows the FlowTimer+ Hub at rest (without alarm).
Without alarm COM is internally connected to NC. In case of alarm COM is internally connected to NO.
03/19 FlowTimer+ Hub Set 15
Page 18
Installation
Note:
The mobile app used only needs to recognize that the charger has been removed. We recommend only Apps, without Clouddienste etc.. Only apps that can send an SMS directly from your smartphone!
6.6 Charging connection Smartphone
According to figure 6.2, the power supply socket (6) is internally connected to the USB charging socket (10) in idle mode (without alarm).
The included micro USB power supply can therefore charge an external smartphone.
In the event of an alarm, the USB charging socket (10) is internally disconnected and charging is interrupted.
This separation can then be evaluated using Mobile App.
6.7 Smartphone app
There is a large selection of mobile alarm system apps for smartphones available on the Internet, which can help an outdated smartphone to develop a new application.
For example, we can recommend the SALIENTEYE App, which can be downloaded from www.salient-eye.com .
Which mobile app you ultimately choose depends on your device and your personal requirements.
03/19 FlowTimer+ Hub Set 16
Page 19
Operation and Function
Green
(duration)
There's no alarm pending.
Red (duration)
An alarm of a FlowTimer+ has triggered a group alarm (see also chapter 9.2.1).
7 Operation and Function
7.1 Operating conditions
7.1.1 Normal operation
An operation of FlowTimer+ Protect is not necessary, because an alarm as well as its resetting is done automatically by the upstream FlowTimer+ systems.
7.1.2 Restarting the system
Unplug the AC adapter (1) from the wall outlet or disconnect the
power supply.
wait ten seconds Restore power supply
7.2 Status display
03/19 FlowTimer+ Hub Set 17
Page 20
Troubleshooting, Maintenance
Power failure
In the event of a power failure, all FlowTimer+ and
FlowTimer+ Protect open automatically and connect the downstream piping systems to the respective supply.
The power supply for the FlowTimer+ Hub is then also no
longer powered, the charging of the smartphone is interrupted and its mobile app can then send an alarm via SMS.
CAUTION
Make sure that you use the same supply voltage for all FlowTimer+ and FlowTimer+ Hubs.
8 Troubleshooting, Maintenance
The protective function is no longer given!
03/19 FlowTimer+ Hub Set 18
Page 21
Troubleshooting, Maintenance
Red (duration)
An alarm via the I/O port has triggered a group alarm.
An operation of FlowTimer+ Hub is not necessary, because an alarm as well as its resetting is done automatically by the upstream FlowTimer+ systems.
8.1 No display
If the FlowTimer+ Hub does not indicate a status, make sure that the power supply is working and that the power supply is plugged in correctly.
If there is still no display, the power supply unit may be defective.
8.2 Alarm signals
8.2.1 Status display permanently red
Examination:
Check the status indicators of each FlowTimer+ system (please
follow the FlowTimer+ Set instructions).
03/19 FlowTimer+ Hub Set 19
Page 22
Troubleshooting, Maintenance
interval
plot
Monthly
Check entire system restart and function (see "FlowTimer+ Set instructions").
Biennial
The FlowTimer+ Hub should be checked by an installer after two years at the latest.
8.3 Maintenance
03/19 FlowTimer+ Hub Set 20
Page 23
Packaging, Transport, Storage
Transport damage!
Inadequately protected systems can be damaged during transport.
Protect the system from moisture and dirt and transport it
in shockproof packaging.
Avoid exceeding or falling below the permissible storage
temperature.
Protect electrical connections from damage with
protective caps.
Incorrect storage can cause damage to the system!
Store system dry and dust-free! Storage temperature: -30°C to +60°C
9 Packaging, Transport, Storage
The system must be transported or stored in its intended packaging until it is installed.
03/19 FlowTimer+ Hub Set 21
Page 24
Disposal
Note on the Electrical and Electronic Equipment Act (ElektroG):
Please dispose of old equipment at a municipal collection point as required by law, or hand it over to your local dealer free of charge.
Disposal with household waste is expressly forbidden according to the Old Equipment Ordinance!
You can return devices received from us to us free of charge after use by sending them back sufficiently franked by post to the address given in the imprint.
Old appliances that contain harmful substances are marked with the symbol of a crossed-out dustbin.
10 Disposal
Information on the Waste Equipment Ordinance
Act on the placing on the market, take-back and environmentally sound disposal of electrical and electronic equipment (Elektro­und Elektronikgerätegesetz - ElektroG).
03/19 FlowTimer+ Hub Set 22
Page 25
EC Declaration of Conformity
11 EC Declaration of Conformity
after: Annex III of the EC Low Voltage Directive 2014/35/EU. Annex I of the EC Directive on Electromagnetic Compatibility 2014/30/EU. RoHS Directive 2011/65/EU on the restriction of the use of certain hazardous
substances in electrical and electronic equipment. The usetech GmbH
Tanzplatz 10 D-55130 Mainz
declares that Product Name: Flowtimer+ Hub
Type: V2.2 Year of construction: 2017
complies with the provisions of the above-mentioned EC Directives. The following standards and technical specifications have been applied: DIN EN 61326-1; VDE 0843-20-1:2013-07 Date: 31.07.2017
Name: Dipl. Ing. (FH) Stefan Windisch Function: CEO
Signature:________________________
03/19 FlowTimer+ Hub Set 23