URC VL-9534-MD-X, VL-9542-AD-X Installation Instructions Manual

INSTALLATION INSTRUCTIONS WARNING:
• Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring.
• Never wire any electrical device with power turned on. Wiring dimmer with power on may cause permanent damage to dimmer and void warranty.
• If you are not sure about any part of these instructions, please contact a licensed electrician.
1. Use only with 120V AC 60 Hz.
2. Do not exceed maximum rating of the dimmer as indicated on the device.
3. Must be installed and used in accordance with electrical codes.
4. If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation.
5. For use ONLY with permanently installed 120V AC incandescent/halogen fixtures.
6. To avoid overheating and possible damage to other equipment, do not use to control receptacles, fluorescent lights, motor-driven appliances, transformer supplied appliances, etc.
7. Use only #14 or #12 copper wire rated for at least 75º C with these devices.
8. Minimum Lamp Wattage:
Single Location Control = 60 Watts. Multi-location Control = 100 Watts
NOTES:
1. The RF Master Dimmer (VL-9534-MD-X) is wired directly to the light fixture.
2. For multi-location installations one RF Master Dimmer is used with RF Accessory
Dimmer(s) VL-9542-AD-X.
3. The VL-9542-AD-X requires hardware connection to the RF Master Dimmer. Refer to
installation instructions for wiring.
4. The RF Master Dimmer is not compatible with standard 3-way switches.
5. For multi-location installations, the RF Master Dimmer is the only device that is
included in the RF Network.
6. Do not exceed maximum load of 600 watts.
Z-Wave Device Network Installation Instructions for RF Master Dimmer Only:
1. This product may be added to a new or existing Z-Wave network. The device has a
blue LED, which will blink when the device is not included in a Z-Wave network. The LED stops blinking when the RF Master Dimmer is in a network.
2. To include this device in a Z-Wave network, select the command on your Z-Wave
controller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then press the RF Master Dimmer ON/OFF switch one time to include it in the network. The LED will stop blinking.
3. To exclude this device from a Z-Wave network, select the command on your
Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the RF Master ON/OFF switch one time to exclude it from the network. The LED will start blinking.
4. This product works with other Z-Wave products from different vendors and
product categories as part of the same network.
5. This product is a listening node and it will act as a repeater in the Z-Wave
network. It will perform the repeater function with Z-Wave products.
6. For multi-location install; blue LED will blink on all wired units, when the RF Master
Dimmer (VL-9534-MD-X) is not included in the Z-Wave network. After including the RF Master Dimmer in the Z-Wave network, the LED will stop blinking. The VL-9542-AD-X (no neutral) Accessory Dimmer need not be included in the Z-Wave network.
IMPORTANT:
RF Master Dimmer will not work or will become damaged if wired incorrectly and the warranty will be voided.
Troubleshooting Guide
Symptom Possible Cause Solution
No Function. LEDs is OFF A) Light bulb(s) burned out
B) Circuit breaker is off or
tripped
C) Disconnect switch on the
dimmer is pulled out to the
OFF position D) Improper wiring E) Defective dimmer
A) Replace light bulb B) Turn on the circuit breaker C) Push in the disconnect
switch on the dimmer D) Check and correct wiring E) Replace dimmer
Erratic operation or flickering LEDs
A) Lamp power is less than 60 Watts B) Loose wiring connections
A) Increase lamp power to at least 60 Watts B) Check and correct wiring
Functions normally using the dimmer push buttons but not from Z-Wave controller and one of the blue LEDs blinks ON and OFF about once per second
Dimmer is not included in Z-Wave network
Include dimmer in a Z-Wave network using a Z-Wave controller. Refer to Z-Wave controller user manual for details
Functions normally using the Master dimmer control but not from Z-Wave controller and no LEDs are blinking
Problem with RF communication on dimmer
A) Relocate Z-Wave controller B) Replace dimmer
Functions normally both lo­cally and from a Z-Wave con­troller but can’t be controlled from a dimmer accessory switch (VL-9542-AND-X) or other Z-Wave device
The dimmer accessory or other Z-Wave device is not associated with the dimmer you wish to control
Create an association between the dimmer acces­sory or other device and the dimmer. Refer to your Z-Wave controller user manual for details
Dimmer is warm to touch after a period of time
This is normal No action required
(Cut if necessary)
Strip 5/8”
Suggested Tools
ON/OFF SWITCH
• Press once to turn lights ON at previously selected level.
• Press again to turn lights OFF.
• When lights are OFF, press and hold for 2 seconds for full brightness.
• When lights are ON, press and hold for 2 seconds until the blue LED blinks. After the preset delay, the lights will begin fading to OFF (up to 4 minutes).
• ON/OFF LED indicates that dimmer is turned on.
READ BEFORE INSTALLATION!
Switch Identification
ACCESSORY
ACCESSORY
ACCESSORY
Master Control
(VL-9534-MD-X)
Accessory
(VL-9542-AD-X)
Disconnect Switch
Red
Black
Green
Green
Blue
Blue
RF MASTER DIMMER – VL-9534-MD-X FOR INCANDESCENT FIXTURES ONLY / NO NEUTRAL REQUIRED RF ACCESSORY DIMMER – VL-9542-AD-X
BlackRed
Blue
Hot
Neutral
120V
Master Dimmer (3-way location)
Connects to Power
Green
Ground
Red
Green
Ground
Tag
WhiteWhite
Accessory Dimmer (4-way location)
White
White
Blue
Green
Ground
Accessory Dimmer (3-way location)
Connects to Light Fixture
White White
Blue
Blue
Blue
ACCESSORY
ACCESSORY ACCESSORY
ACCESSORY ACCESSORY
Light Fixture
2.6
Accessory - 4-way Location
Blue
ACCESSORY
Blue
Traveller Wires
From
Master Dimmer
To
Accessory Dimmer
The color of these
traveller wires is
same as noted
in Step 2.3
White
2.5
White
Black
Red
Red
Bare
Black
Green
Tag
2.4
Accessory
Blue
ACCESSORY
ACCESSORY
Connect
to bare
wire
Traveller Wires
Note the color of
this traveller wire
White
Light Fixture
From Master Dimmer
Blue
Green
Tag
2.3
Master Dimmer
Black
ACCESSORY
Connect
to bare
wire
Traveller Wires
Note the color of this traveller wire
Red
Blue
White
Power
To Accessory
dimmer
2.2
Black
Red
Hot
Neutral
120V
Light Fixture
Green
Ground
MASTER
DIMMER
White
MASTER
DIMMER
Blue
1.5
Master
Black
Black
White
Green
Red
Black
Power
Blue
1.4
Single Location Control Installation (requires one RF Master Dimmer)
Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring. Identify existing wiring (This switch will be a single-pole)
and tag “Hot” wire. Use voltage tester as necessary to confirm “Hot” wire (Voltage will be present at the “Hot” wire when the lights are off).
Gently push dimmer into place and secure with mounting screws. Make sure disconnect switch at bottom of master is fully pushed in
Two Location Control Installation (requires one Master and one Accessory)
Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring. Identify existing wiring (both existing
switches will be “3-way”) Tag common wire on both 3-Way switches (see “How to Identify Common Wires” section*)
Three Location Control Installation (requires one Master and two Accessory dimmers)
Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring. Identify existing wiring
(4-way switches) Tag common wires on 4-Way switch.
(see “How to Identify Common Wires” section*)
Connect the second Accessory Dimmer (4-way switch) as shown.
IMPORTANT! How to identify Common Wires
*
Two location:
Each switch will have insulated wires connected to three terminal screws plus a green or bare wire connected to a green terminal screw. The three terminals are usually one dark colored screw and two light colored screws (ignore the Green screw). Alternatively, the three screws may be the same color and one will be marked COMMON or COM Find the wires connected to the dark or COMMON screws. Usually these wires are black but may be red or blue. Tag these wires on both switches to identify when wiring.
Three location:
Two of the existing switches will be 3-way. The 3-way switches will be located at each end of the circuit with a 4-way switch in between. TAG the two 3-way switches as in the Two Location Control section. The 4-Way switch has 4 insu­lated wires connected to 4 terminal screws. VERY IMPORTANT - TAG two same color insulated wires, which are connected to screws of opposite colors.
Refer to 1.4 to push dimmers into place.
Black
1.3
White
Black
Bare
1.1
1.6
TOP
1.4
2.1
Black
Bare
Black
Red
Tag
White
2.1
3.1
Tag
-
To Light
- Hot
Identify existing wiring (This switch will be a single-pole).
Connect master dimmer as shown.
Disconnect existing switch and remove.
Connect RF Master Dimmer as Shown. Note the color of the traveller wire you have connected to the blue wire. Connect green wire to bare wire in box
Connect the Accessory Dimmer as shown. You must connect the tagged wire to the same traveller wire color noted in Step
2.3. Connect green wire to bare wire in box.
Light Fixture
ACCESSORY
ACCESSORY ACCESSORY
Master Dimmer location
(connects to power)
Accessory Dimmer location
(connects to Light Fixture)
Refer to 1.4 to install device in the wallbox.
IS-RF9534U-EN (REV. A)
Universal Remote Control, Inc. 500 Mamaroneck Ave. Harrison, NY 10528 (914) 835-4484 techsupport@UniversalRemote.com www.UniversalRemote.com
Paper Size: 8.5"W x 14"H (Legal) 2 sided print, Z-Fold 4 panels, then Fold in half with logo at the top of page facing outward.
Final Size: 4.3"W x 3.5"H
Loading...