U-Prox HW Installation Manual

U-PROX HW Installation manual
Features
Power:
o External power supply, 12V:
Current consumption max 150 mA @ 12V Maximum voltage ripple 500 ma peak to peak
Direct operation with U-Prox IP500 panels
o ISM band (915.5-927.5 MHz) device with bi-directional communication o Guaranteed range of 20 m o U-Prox IC L connection interface – wireless computer network Wi-Fi
One micro USB B port for network settings configuring and firmware upgrade Communication interface IEEE 802.11b/g/n (Open, WPA-PSK, WPA2-PSK) Adjusted with U-Prox IP software. Supports automatic configuration for one-range network. Overall dimensions of device enclosure – 120 х 40 х 355 mm Temperature range: 0 - +55
0
C at 80.% relative humidity.
Maximum relative humidity 80% without condensation
Repeater
The look of the repeater is shown in Fig. 1
Fig. 1. U-Prox HW repeater
Location of connectors on repeater board and their function is shown in Fig. 2
Figure 2. U-Prox HW board
1. The Encl osure
2. Panel board
3. Connectors
3 1
2
Fig. 4. Fixing holes marking
Assignment of the repeater contacts and indication
Contact
Name
Purpose
+12V
+12V
External 12V power supply connection
GND
GND
USB Connector
Micro USB B
USB Connector
For network settings configuration and
firmware upgrade
Button
BUT
BUT
Service button
Light emitting diode
LED – bi-color light emitting diode
No connection to the Wi-Fi access point - Yellow flashes Wi-Fi module malfunction – Yellow lights steadily Normal mode
o No connection to the U-Prox IC L – red flashes 2 times per second o Connected to the U-Prox IC L – green flashes once per second
Firmware upgrade - red flashes frequently
How to work with the device
U-Prox HW repeater shipped in the plastic enclosure without the power supply. Dimensions marked on the Fig. 3.
Connection procedure
1. Perform initial network setup of repeater (that
specifies settings of network parameters) with utility "Configurator" via USB port before installation, if it is impossible to adjust them automatically
2. Prepare the place for installation mark and drill
mounting holes (see Mount recommendations)
3. Perform power wiring
4. Remove the repeater board from the enclosure
5. Install and fix the repeater enclosure back
6. Install the board into the enclosure
7. Connect the power wiring
8. Install and fix the enclosure cover with screw
9. Connect the repeater in the U-Prox IP software
(according to the software manual)
10. Download the repeater
11. The repeater is ready for operation
Mount recommendations
Place the repeater in the place, convenient for service. To mount the repeater on the wall (see Fig 4.) perform actions:
Open the enclosure cover, remove the board and mark fixing holes using the
enclosure bottom as template
Pull the power wiring through the opening in the enclosure Fix the enclosure bottom Connect the power wiring
Fig. 8. Dimensions