Features
Power:
o Micro USB B o IEEE 802.3af PoE: power class 1, up to 3,84W
o ISM band (915.5-927.5 MHz) device with bi-directional communication o Guaranteed range of 20 m o U-Prox HE connection interface - Ethernet
One micro USB B port for network settings configuring and firmware upgrade Isolated Ethernet port, 10BASE-T/100BASE-TX, 802.3af PoE U-Prox HE adjusted with U-Prox IP software and supports automatic configuration for one-range
network.
Temperature range: 0 - +55
0
C at 80% relative humidity.
Maximum relative humidity 80% without condensation
Panel
The view of the Device is shown in Fig. 1
Figure 1. U-Prox HE
Location of jumpers and connectors on Device board and their function shown on Fig. 2:
Figure 2. U-Prox HE board
1. Ethernet port
2. Micro USB B port
3. Reset button
1
2
3
Figure. 3. Dimensions
Figure 4. Fixing holes marking
Assignment of the access Device connections
Contact
Name
Purpose
USB Connector
Micro USB B
USB Connector
For network settings configuration and
firmware upgrade
Jumper
BAT
BAT
For memory and Real-Time Clock backup
battery switch
Button
FUNC
FUNC
Service button
Light emitting diodes (LED’s)
LED’s from left to right:
Link LED Ethernet cable is OK when lit
Act. LED Frequent flashing means data exchange
LED – bi-color LED:
Red flashes 2 times per second – no connection to the ACS server Green flashes once per second – connection to the ACS server is OK
Connection and mounting
U-Prox HE shipped in the plastic enclosure without the power supply. Dimensions marked on the Fig. 3.
Connection
1. Perform initial network setup of
device (that specifies settings of network parameters) with utility "Configurator" via USB port before installation, if it is impossible to adjust them automatically
2. Prepare the place for installation
mark and drill mounting holes (see Mount recommendations)
3. Perform Ethernet wiring
4. Perform power wiring if it is necessary
5. Install and fix the enclosure cover with screws
6. Attach self-adhesive washers over the screws
7. Load the Device in the U-Prox IP software (according to the software manual)
8. Download the Device
9. The device is ready for operation
Mounting recommendations
Mount the Device in the place, convenient for service.
To mount the Device on the wall, perform the following (Figure 4.):
Mark the holes using the tem plate
provided;
Fix the enclosure; Connect wires
Template for device installation -----------------------------------------------------------------------------------------------------------