Congratulations on your purchase of a UPM timer. Please take the time to read and understand this manual so you can begin to enjoy the security and energy saving benefits this product has to offer.
FEATURES
!
!
!
!
!
!
20 ON programs / 20 OFF programs
3 random functions
12/24 hour clock
500W loading
single pole or three-way
Countdown timer -
“One-TouchCountdown”
SINGLE POLE INSTALLATION
1 2
Remove existing switch and identify the wires in the wall box.
Using the supplied wire nuts, securely fasten the wires on the timer to the wires in the wall box according to diagram FIGURE 1.
3
Disconnect the power supply at the circuit breaker or fuse before proceeding with the installation.
Connect one of the (hot) wire on the timer to the wire in the wall box.
black hot
Connect the other (hot) wire on the timer to the wire in the wall box coming from the light fixture.
black hot
GETTING STARTED
setting the clock
1
4
2
1
5
6 7
8
Press SET
Day select with
Press SET
Hour select with
Press SET
Minute select with
357 9 2 4 6 8
10
9
10
3
Press SET
Second select with
Press SET
Press SET
Minute select with
memory backup
This UPM wall switch timer comes with built-in memory backup protection. In the event of a power outage, all program and clock settings will remain in memory.
CLOCK
ON
MO
CLOCK
ON
MO
To activate/deactivate Daylight Saving Time(DST) function, press and hold both and together for 3 seconds in mode; solid for DST
CLOCK
To toggle between 12/24 hour format, press RND during clock setting
CAUTION!
*
This timer is only compatible with incandescent (120V) lighting applications. The timer must be used with magnetic transformers, motors or loads exceeding 500W.
NOT
All wiring must comply with applicable codes and regulations.
TO AVOID FIRE, SHOCK, OR DEATH; SHUT OFF POWER SUPPLY AT THE CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING.
Handle installation with caution to prevent any risk of electrical shock that could cause serious injury or death. If you are not sure about any part of the given instructions, consult a qualified electrician.
For proper grounding, connect the (ground) wire on the timer to the ground “screw” found inside the wall box.
green
Mount timer into the wall box carefully.
Restore power supply at the circuit breaker or fuse.
4 5
Terminate the (three-way) wire on the timer with a wire nut. (For a single pole installation, the red wire is not needed).
red
INSTALLING THE TIMER IN PLACE OF LOAD SWITCH
FIGURE 3
THREE-WAY INSTALLATION DIAGRAM
JUMPER WIRE
COMMON TERMINAL
HOT WIRE
HOT WIRE
CLOSE UP VIEW OF THE HOT SWITCH
Go to using
CLOCK
GETTING STARTED
button placements
display
1 2
CD - activates countdown timer
3 4
SET - activates set functions
RND - activates random functions
5
- scrolls through selections
6
ON/OFF - manual on/off control
7
Main On/Main Off
R - reset
1
4
2
5
6
7
3
CLOCKCD
SET
RND
L
-
PROG
ONOFF
MO TU WE TH FR SA SU
X
Set function indicator
Weekday indicators
Random function indicator
AM/PM
Clock function indicator
Disabled program icon
ON/OFF indicator
8
8
One-Touch Countdown Button
One-Touch Countdown
Countdown function indicator
Power Source
Red
ETW193
JUMPER
3Way
Black
Black
LOAD
COMMON
Green
HOT SWITCH
PAGE 1 PAGE 2 PAGE 3
PAGE 10 PAGE 11 PAGE 12
SINGLE POLE INSTALLATION DIAGRAM
FIGURE 1
PROG
ON
MOTU WETH FR SA SU
1
357
2 4 6 8
PROG
ON
MOTU WE THFR SASU
432
1
X
THREE-WAY INSTALLATION
1 2
Remove existing switch and identify the wires in the wall box.
Using the supplied wire nuts, securely fasten the wires on the timer to the wires in the wall box according to diagram FIGURE 2.
3
Disconnect the power supply at the circuit breaker or fuse before proceeding with the installation.
Connect one of the (hot) wire on the timer to the wire in the wall box.
black hot
Connect the other (hot) wire on the timer to the wire in the wall box coming from the LOAD switch.
black load
Connect the (three-way) wire on the timer to the wire in the wall box coming from the LOAD switch.
red three-way
Mount timer into the wall box carefully.
Restore power supply at the circuit breaker or fuse.
4
8
THREE-WAY INSTALLATION
There are two switches in a three-way circuit. The switch directly connected to the circuit breaker is the HOT switch. The second switch is the LOAD switch. Ensure you know which switch you are replacing.
INSTALLING THE TIMER IN PLACE OF HOT SWITCH
For proper grounding, connect the (ground) wire on the timer to the ground “screw” found inside the wall box.
green
ADDING A JUMPER WIRE TO THE LOAD SWITCH
*
Disconnect the power supply at the circuit breaker or fuse before proceeding with the installation.
5
Take out the LOAD switch and identify the terminal.common
6
Connect the wire to the LOAD switch according to diagram FIGURE 2.
jumper
Connect the wire from the terminal to the
terminal of the LOAD switch.
jumper common
hot
Mount LOAD switch back into the wall box carefully.
7
Load Switch
Power Source
3-Way
Timer
Select program 20 with
Flashing for short random Flashing for long random
RANDOM FUNCTION
3
2
1
short/ randomlong
programmable random
4
1 2
Press RND
Set program 20 to desired random time
3 4
1 2
Press RND
3
Short random from OR Long random from
CLOCK
CD
RND L
RND
-
Solid for programmable random
RND
* Short random 1-2 hours, long random 2-3 hours
* Programmable random only works with program 20; 1-2 hours
3
2
1
Deactivate random function with RND or ON/OFF
COUNTDOWN TIMER
1
4
2
5
6 7
8
Press SET
Start ON or OFF select with
Press SET
Hour select with
Press SET
Minute select with
9
10
3
Press SET
Second select with
Press SET
The to-the-second countdown feature of this timer starts from the ON or OFF position and counts down to zero when activated.
CD
PROG
ON
357 9
1
2 4 6 8
10
CD
PROG
ON
Stop countdown timer with CD or ON/OFF.(or )One-Touch Countdown Button
Select CD mode using
Press CD or the to start the countdown timer.One-Touch Countdown Button
PROGRAM SETTINGS
disable program/master disable
1
4
2
5
7 8
*
*
Press SET
Day select with
* Individual days / weekly selections
Press SET
Hour select with
Press SET
Minute select with
3
Press SET
Each program has an “ON” and “OFF” setting. Both must be set for operation. Example: PROG 1 has an “ON” and “OFF”
Program select with
1 2
Press SET
Press ON/OFF to disable ( )X
3
For select PROGRAM with
or go to using
single disable
F master disable
Press SET 3 times to exit (single disable) OR press SET 4 times to exit (master)
CLOCK
Programs are arranged in a circular pattern with the clock and countdown functions:
CLOCK
Program 1–20
CD
4
Repeat steps to to undo disable )(X
1
4
For a single program disable, both the “ON” and “OFF” setting must be disabled individually
6
ETW193
Black
Black
Green
LOAD
Power Source
Black
Screw
Red
PAGE 4 PAGE 5 PAGE 6