UNO LASER X-LRGB 1W ILDA User Manual

1 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
X-LRGB 1W ILDA
LASER LIGHT FIXTURE – CLASS 4
LASER LIGHT
CLASS 4 LASER PRODUCT
CLASSIFIED PER EN/IEC 60825-1 2007
UNO LASERS FIXTURES ARE APPROVED FOR SAFE USE IN USA!
THIS DEVICE COMPLIES WITH PERFORMANCE STANDARS FOR LASER
PRODUCTS UNDER 21 CFR 1040 EXCEPT
WITH RESPECT TO THOSE CHARACTERISTICS AUTHORIZED BY
VARIANCE NUMBER: “2013-V-0607
2 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
USER INFORMATION
USER INFORMATION
This manual contains important laser operation information. Read and understand all instructions prior to powering on laser unit the first time, to avoid laser eye injury and to avoid breaking the law. Keep this manual in a safe place for future reference.
WARNING DATA
Lasers can be hazardous and have unique safety considerations. Permanent eye injury and blindness is possible if lasers are used incorrectly. Pay close attention to each safety REMARK and WARNING statement in the user manual. Read all instructions carefully BEFORE operating this device.
NON-INTERLOCKED HOUSING WARNING
This unit contains high power lasers internally. Do not open the laser housing, due to potential exposure to unsafe levels of laser radiation. The laser power levels accessible if the unit is open can cause instant blindness, burn skin, and cause fires.
VARIANCE
A "Laser Light Show Variance" is the permit required from FDA for operating UNO Lasers in a public forum & outlined in details under FDA guidelines for Laser Display Show. If you are producing a show with laser light effects, not having a show variance could lead to large fines if your show gets inspected by FDA officials.
Demonstration laser products are only to be purchased and used by organizations which already hold a valid Class 3B or Class 4 US laser light show variance!
Visit our website to apply for your FREE Laser show variance
http://variance.ProXdirect.com
WARRANTY 1 Year Laser Diods & Scanner 2 Years General Parts Life Time Clean & Calibrate Each Uno Laser system will be cleaned and re-
calibrated at no extra cost each year for the life of the unit. (Shipping not included)
Please register your new purchase with us for your warranty with Uno Laser within 30 days of your purchase.
http://warranty.ProXdirect.com
3 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
SAFETY NOTES_
LASER RADIATION WARNING / SAFETY
Please note there is high potential for eye and skin injury if
strict adherence to these guidelines is not followed.
These Class 3B and Class 4 demonstration laser products are
only to be purchased and used by organizations which already hold a valid Class 3B or Class 4 US laser light show variance.
Do not point laser or allow laser light to be directed or reflected
toward other people or reflect objects.
Laser is never to be operated if the unit is defective or the
cover or seal is damaged.
Direct or scattered light can be hazards to eyes and skin. INDOOR USE ONLY. Outdoor laser shows require prior FAA
written approval.
USER ACCESSIBILITY / MAINTAINANCE
Do not modify the unit or remove protective covers or housing. No scheduled maintenance is necessary to keep this product in
compliance.
Unit must be returned to factory for any required service or
repair.
Service is only to be handled by authorized factory trained
technicians. There are no user serviceable parts, etc.
4 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Unpacking Instructions
CAUTION!
Immediately upon receiving a fixture, carefully unpack the
carton, check the contents to ensure that all parts are present,
and have been received in good condition. Notify the shipper
immediately and retain packing material for inspection if any
parts appear damage from shipping or the package itself shows
signs of mishandling. Save the package and all packing materials.
In the event that a fixture must be returned to the factor, it is
important that the fixture be returned in the original factory box
packing.
What is included?
The carton or flight case contain following items:
Name
QTY
BERMUDA 1W RGB TTL Laser Light Fixture
1PCS
KEYs (for key switch)
2 PCS
6FT Power Cord (Edison to PowerConn)
1 PCS
E-Stop Switch w/ Keys
w/30ft cable
1 PCS
USER MANUAL
1 PCS
5 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Power Supply
To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture of refer to the fixture’s
specifications chart. A fixture’s listed current rating is its average current
draw under normal conditions.
All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.
LASER INFORMATION
This Laser Product is designated as Class 4
during all procedures of operation.
LASER EMISSION DATA
Laser Classification
Class 4
Green Laser
LD 532nm
Red Laser
LD 635nm
Blue Laser
LD 445nm
Beam Diameter
<5mm at aperture
Divergence(each beam)
<2 mrad
Divergence(total light)
<90 degrees
Transverse Beam Mode
TEM00
Cooling
TEC & Fan Cooling
Scanning
DC to 20KHz, ±30 Degrees X & Y
*As measured under IEC measurement conditions for classification.
IMPORTANT
6 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
LASER INFORMATION
Laser Power:
Total 1100mw Beam Divergency Diameter(mm) Red 250mw 635nm < 3.5x0.5 mrad < 2x5mm Green 150mw 532nm < 1.5 mrad < 3mm Blue 700mw 445nm < 2x0.5 mrad < 2x5mm
Scanner: 25kpps@8° High Speed Optical Scanner Scan Angle max.: 60° X/Y Axis Beam Angle: ±30
0
SPECIFICATIONS
Main Input: AC100240V, 50/60Hz Fuse: 250V 2A Slow Blow (20mm Glass) Power Consumption: 45W Control Mode: Auto, Sound, DMX, Master / Slave, ILDA
Laser Safety eyewear and NOHD distance.
Class 4 Safety Data NOHD = 300 meters Safety Eyewear OD (optical density.. Attenutation) = <3.5
Laser Classification: Class 4 Laser Safety Standard: EN/IEC 60825-1 2007 Condition Temperature: 10 400C DMX Connections: 3 pins XLR Male/Female DMX Channels: 12 channels Measurement: L=32cm, W=26cm, H=26cm N Weight: 6Kg / 13lbs
All information provided is subject to change without notice.
7 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
LABEL REPRODUCTION
Safety Label location
As FDA/CDRH required under Laser Compliance Regulations,
here you will find a diagram that outlines the radiation warning labels
and where you will find them located on the unit itself.
8 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
PROPER USE/MINIMUM HEIGHTAUTIN!
CAUTION! - USE OF CONTROLS OR ADJUSTMENTS, OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARD­OUS RADIATION EXPOSURE.
This product is for overhead mounting only.
For safety purposes, ProX and Xstatic Pro Lighting recommend mounting lighting effect products on steady elevated platforms or sturdy overhead using suitable hanging clamps. In all cases, use safety cables.
Obtain appropriate mounting hardware from your lighting vendor.
International laser safety regulations require that laser products must be operated in the fashion illustrated below, with a minimum of 3 meters (9.8 ft) of vertical separation between the floor and the lowest laser light. Additionally, 3 meters of horizontal separation is required between laser light and audience or other public spaces.
LASER VARIANCE
LASER VARIANCE REQUIREMENT!
These Class 3B and Class 4 demonstration laser Products are only to be purchased and used by organizations which already hold a valid Class 3B or Class 4 US laser light show variance
Visit our website to apply for your FREE Laser show variance
http://variance.ProXdirect.com
Do not point laser or allow laser light to be directed or reflected toward other people or reflective objects.
Minimum height requirement: 3 meters, or 10 feet in clearance
3 meters
9 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration.
Cable (EU)
Cable(US)
Pin
International
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green
Green
Earth
Proper Laser Set Up & Usage
This fixture has been designed to be hung. It is recommended for safety purposes, your lighting
effect are properly mounted using a suitable hanging clamp and make sure the area below
the installation place is free unwanted persons during rigging, de-rigging and servicing.
The operator has to make sure that safety-relating and machine-technical
installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical
installations are approved by a skilled persons cannot reach
The fixture should be installed in the position where persons cannot reach and
where persons may walk by or be seated.
PRODUCT OVERVIEW
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
FUSE 5mmx20mm FFUSEF 1 A/250V
CAUTION! When installing the device, make sure there is no highly - inflammable material (decoration articles, etc.) within a distance of min. 0.5m / 20inches
10 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Front Panel
NO
NAME
FUNCTION
1
Emission Indicator
Laser emission LED indicator
2
MIC Sync LED
Synchronize to detected music signal.
3
“DMX On” LED
Indicates DMX Signal is Active.
4
APERTURE
Laser output aperture
5
Beam Block
Sliding laser beam block used for audience safety
11 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Rear Panel
NO
NAME
FUNCTION
6
Rear DMX Sync LED
Indicates DMX Signal is Active.
7
Rear MIC Sync LED
Synchronize to detected music signal.
8
Rear “Power On” LED
Laser emission LED indicator
9
X Y invert
Invert X or Y axis/pattern size zoom control
10
Sound Sense Adjust
Attenuates the Sensitivity to Music
11
Safety Eye
Safety Cable attachment mount
12
MIC, Microphone
Ambient Audio Input for Music Sync
13
Remote Interlock Port
Attaches Emergency Stop box.
14
Key Switch
Switches on and Off the Diode Emissions
15
Laser Control Panel
Intelligent LED control panel of the system
16
DMX Linking
XLR-3PIN Ports, for DMX in/out
17
Fan
ventilation fan
18
ILDA Interface In/Out
ILDA interface for software
19
Main Power Switch
On/Off Switch, Main Power Source.
20
Fuse
2A Fuse
21
Mains input
Main powercon socket
22
Ground Pin
Ground screw
12 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
LCD FUNCTION SETTING
Press “UP” or “DOWN” to choose function in the same menu.
Press “ENTER” button to enter next menu.
Press “RETURN” button to return previous menu.
Menu operating instruction
When you turn on the laser for the first time, it will take some seconds to auto load the built-in show
The default setting is AUTO EFFECT 1.
First Menu
Second Menu
Third Menu
Fourth Menu
DMX512
Running A001 (DMX address)
AUTO (auto running mode)
Running Effect 1 (Full show) Effect 2 (only beam) Effect 3 (only cartoon)
Music (sound activate mode)
Running Effect 1 (Full show) Effect 2 (only beam) Effect 3 (only cartoon)
Setting
Address
Choose DMX address
Light (LCD backlight setting)
OFF ON ON 5S (ON for 5 seconds) ON 10S (ON for 10 seconds)
Cartoon (Running speed)
Press UP and down to choose running speed from 1 99, 99 is the fastest
Master (set master unit)
OFF ON
LASER (size and color setting
Size
(press up or down to choose the size of graphics
Color
1. Single color
(7 colors)
2. RGY
3. GBC
4. RBP
5. RGB
Default (Restore default setting)
Yes NO
UP
ENTER
RETURN
DOWN
DMX-512 Auto
13 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
DMX-512 connection between fixtures
The fixture is equipped with 2-pin XLR sockets for DMX input and output. The sockets are wired in parallel. Only use a shielded twisted-pair cable designed for 3-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.
Occupation of the XLR-connection
DMX – output DMX - output
XLR mounting-sockets (rear view): XLR mounting-plugs (rear view):
Caution: At the laser fixture, the DMX-cable has to terminate with a terminator.
Contact your dealer to purchase ProX Cables DMX Terminator.
SKU: XC-DMX3PTR
Building a serial DMX-chain (DMX Mode)
If you are using the standard DMX-controllers, you can connect the DMX-output of the controller
directly with the DMX-input of the first fixture in the DMX-chain.
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next
fixture. Always connect output with the input of the next fixture until all fixtures are connected.
If you use a controller with 5 pins DMX connector, you need to use a 5 to 3 pins adapter Connect the fixture together in a daisy chain by DMX XLR plug cable from the output of the fixture
to the input of the next fixture. The cable cannot be branched or split to a Y cable. DMX 512 is a
very high speed signal. Inadequate or damaged cables, soldered joints or corroded connectors
can easily distort signal and shut down the system.
Each fixture needs to have a DMX address to receive the data from the controller. The DMX
address number which could be read from rear panel of each fixture is between 001-512
The end of the DMX 512 chain should be terminated to reduce signal errors.
14 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Instruction for DMX channels
CH1
LASER OFF
041
LASER OFF
Auto Activate 4283
DMX mode, CH2CH12 valid
84125
Built-in cartoon graphics auto running mode
126167
Built-in beam graphics auto running mode
Sound Activate 168209
Built-in beam graphics auto running mode
210251
Built-in cartoon graphics auto running mode
252255
DMX mode, CH2CH12 valid
CH2
Pattern select
0255
Selecting built-in patterns
CH3
Rotation 0127
Manual rotation
128191
Auto counter-clockwise rotation (from slow of fast)
192255
Auto clockwise rotation (from slow to fast)
CH4
X axis rolling 0127
Manual rolling
128255
Auto rolling (from slow to fast)
CH5
Y axis rolling 0127
Manual rolling
128255
Auto rolling (from slow to fast)
CH6
X axis moving 0127
Manual choose moving position
128255
Auto moving (from slow to fast)
CH7
Y axis moving
0~127
Manual choose moving position
128~125
Auto moving (From slow to fast)
CH8
Pattern size
0~63
Choose pattern size, 0 is normal size, 1 is the smallest, 63 is
the biggest
Zooming
64~127
Auto zooming (-) from slow to fast
128~191
Auto zooming (+) from slow to fast
192~255
Manual zooming (+/-) from slow to fast
CH9
Drawing
0~255
Auto drawing from slow to fast
CH10
Scanning speed
0~127
Choose scanning speed from slow to fast
Display dot
128~255
Choose the length of dot
CH11
Color setting
0~24
Normal color
25~199
Choose every single color
200~224
Every single color changing one by one
225~255
All the colors together changing alternatively in
pattern
CH12
Color change
speed
0~255
Adjust color changing speed from slow to fast
15 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
TROUBLE SHOOTING
1. If the power indicator is off the laser doesn’t work, please check the Power
Cord, fuse and power supply.
2. In Stand-Alone operation, if the power supply indicator is ON and sound
active indicator is OFF, but the laser doesn’t work.
The sound may be too small and cannot activate the laser running,
please increase the music volume or increase sound sensitivity on rear panel.
Please check if unit has been set up in slave mode, or DMX mode.
3. In Master-Slave operation, if slave fixtures don’t run; Make sure there’s only one master in the chain, and the others are
set in Slave mode.
Make sure to use a good quality DMX and Power Cables to run the
chain.
4. In DMX operation, if the unit can’t be controlled by the DMX console, but
the DMX signal indicator on the item is flashing, Please make sure the DMX console and fixture have the same channel.
After trying the above solution you still cannot sort out the problem, please contact your Dealer or UNO LASER for service.
1. Please use this device only according to these operating instructions.
2. Do not use the device if there are any visible damages on housing, connector panels, power supplies or power cords.
3. Never look directly into the light source of a laser projector. Danger of damage to the eyes or even blindness in extreme circumstances!
4. Do not operate the device at high humidity, in the rain or in dusty environments.
5. Protect device against dripping or splashing water. Do not place any liquid filled containers near to this device.
Any warranty claims are void if the warranty label is removed or tampered with in any way.
All information provided in this manual is subject to change without notice.
16 | BERMUDA X-LRGB1W ILDA USER MANUAL V2016-A
Please register your new purchase with us for your warranty with
Uno Laser within 30 days of your purchase.
http://warranty.ProXdirect.com
Our Products and You
Year after year, we are continuously blown away by the amazing productions we see happening around the world with ProX Gear! We especially want to thank all our dealers, and all our seriously talented customers who choose ProX, for your support and creativity! Be sure to tag us on social media like Facebook and Instagram, or send us your best images of you and your favorite ProX Gear to our website! THANK YOU!
#unolaser
Follow us:
facebook.com/unolaserusa
UNO Laser
25 Colgate Rd Great Neck NY
Tel: 718-237-2299
www.unolaser.com unolaser@gmail.com