User Manual
ISS1/14
Electronically controlled
dispensing pump
BOXER 9100
Box contains
The following:
Boxer 9100 pump controller ........................................................... Cat. No. 9110.000
PSU output 24V 1A with universal plug adapters........................... Cat. No. 9200.004
Set tube clips No. 1 ......................................................................... Cat. No.9000.601
Set tube clips No. 2 ......................................................................... Cat. No.9000.602
Set tube clips No. 3 ......................................................................... Cat. No.9000.603
(1)IDØ2.0mm Silicone tube1 metre ............................................ Cat. No. 9000.509
(2)In line connector tube to yellow tip .................................................... Cat. No. 3923
(3)Tip holder support .................................................................... Cat. No. 9100.3003
(4)Yellow Dispense Tip 1-100µl LW1035 .............................................. Cat. No. 3530
This instruction manual .................................................................. Cat. No. 9110.003
Accessories & spares:
Silicone Tubing IDØ1.0mm complete with connectors ..................... Cat.No.9000.504
Silicone Tubing IDØ2.0mm complete with connectors ..................... Cat.No.9000.505
Silicone Tubing IDØ3.0mm complete with connectors ..................... Cat.No.9000.510
Santoprene Tubing IDØ1.0mm complete with connectors ............... Cat.No.9000.501
Santoprene Tubing IDØ2.0mm complete with connectors ............... Cat.No.9000.502
Santoprene Tubing IDØ3.0mm complete with connectors ............... Cat.No.9000.518
Santoprene tubing ID Ø1.00mm1meter running length .................... Cat.No.9000.521
Santoprene tubing ID Ø2.00mm1meter running length .................... Cat.No.9000.506
Santoprene tubing ID Ø3.00mm1meter running length .................... Cat.No.9000.515
Silicone tubing ID Ø1.00mm1meter running length.......................... Cat.No.9000.507
Silicone tubing ID Ø2.00mm1meter running length.......................... Cat.No.9000.509
Silicone tubing ID Ø3.00mm1meter running length.......................... Cat.No.9000.508
Bag of 25 Yellow Dispense Tips1-100µl LW1035 ............................ Cat.No.9100.005
Spare dispense set consisting of above items 1-4 ........................ Cat. No. 9100.006
Unoverse 9100 wall mounting bracket/stand ................................... Cat.No.9100.001
Foot Switch ............................................................................................ Cat.No. 6013
Product Specification:
Mains Voltage ............................................................ 100V-240V 0.3A MAX 47-63Hz
Power Supply Unit output ...................................................................... +12VDC 0.5A
Environmental operating temp ............................................................ +10°C to +40°C
Environmental storage temp ................................................................. +4°C to +40°C
Environmental operating RH ................................................................................. 90%
Environmental storage RH .................................................................................... 95%
Acetaldehyde Chloroacetic acid Linseed Oil Potassium salts Acetic acid Chronic acid Magnesium salt Silver salts Acetic Anhydride Chromium salts Maleic acid Soap solutions Acrylonitrile Copper salts Manganese salts Sodium salts Aluminum Chloride Ethylene glycol Mercury salts Sodium hydroxide Aluminum sulfate Ferric salts Methanol Sodium hypochlorite Ammonia Fluoborate salts Natural gas Stearic acid Ammonium salts Fluoboric acid Nickel salts Sulfur dioxide
Ammonium hydrox­ide
Fluosilicic acid Nitric acid-10% Sulfuric acid, dil.
Amyl acetate Formaldehyde Nitroethane Sulfurous acid Antimony salts Formamide Nitrogen oxides Tannic acid Arsenic salts Formic acid Nitr ous acid Tanning extracts Barium salts Glucose Oils, animal Trisodium phosphate
Benzoic acid Glycerins Oils. mineral Urea Bleaching liquor Hydrochloric acid Oils. vegetable Uric acid Boric acid Hydrocyanic acid Oxalic acid Water Bromine Hydrogen peroxide Oxygen Water (brine) Butyric acid Hydrogen sulfide Phosphoric acid Water (stoam) Calcium salts Iodine and solutions Phthalic acid Zinc salts
Carbon Dioxide Lactic acid Phosphoric acid
Chlorine (wet/dry) Lead salts Plating solutions
Acetates Butane Me Et Ketone Skydrol 500-B4 Acetone Butanol Nitric acid-30% Sulfuric acid-90% Alcohols Essential Oils Nitrobenzene T etrahydrofuran Amyl alcohol Ethers Oleic acid Turpentine Aniline Ethanol Phenol Benzaldehyde Furfural Propanol Benzyl alcohol Li thium grease Pyridine
Benzene Cyclohexane Kerosene Nitric acid- 70%
Carbon tetrachloride Ethyl chloride Trichloroethylene Perchloroethylene
Chlorobenzene Freon Lacquer Toluene Chloroform Gasoline, unleaded Naphtha Xylene
Little or no effect on Santoprene
Severe
Moderate effect
Chemical compatibility chart
1. A. Unpacking
Remove the packing materials, unpack the pump controller and the power supply unit.
Make sure that you have got all the components as specified in ’Box Contains’ last page of
this manual.
Please contact your supplier if you notice any one of the components is missing or damaged.
Note: Do not attempt to assemble a unit using damaged components.
Retain the packaging so it can be used for future shipping.
The plug-in power supply unit is Switch Mode and automatically adjusts itself to the mains power supply characteristics. It will work with any mains voltage supply from 100V to 240V. The power supply unit is shipped with three alternative plug adaptors to fit European, American and UK power outlets. Select the correct adaptor for your needs and clip it into the power supply.
2. General information on peristaltic pumps
Peristaltic tube pumps are ideal for fluid transfer, metering and dispensing. In contrary to centrifugal and gear pumps, peristaltic pumps handle fluids of various viscosities, are self priming and can operate in either flow direction.
With no valves, seals or packing to come in direct contact with the pumped fluid, they are ideal for pumping high purity & corrosive fluids and for contamination free dosing.
The principle of the peristaltic pump is based on a tube which is occluded by a series of rollers. As a general rule, the higher the number of rollers and the smaller the tube diameterthe lower are the flow rates but better is the accuracy and precision.
The 9100 controller is equipped as a standard with 3 roller system and Ø2.0mm ID tube. This tube diameter together with maximum speed delivers a flow rate of 48ml/min.*
The highest dispense accuracy is achieved by using a semi rigid tube on the outlet of the pump. We recommend thin wall tubing such as FEP or PVC tube.
*83ml/min for the 9110.010 which has max rotor speed of 520rpm
Page 1
3. The peristaltic tube
The supplied peristaltic tube is made from Silicone. Please make sure the reagents you intend to use are compatible with these material.
3. A. Clamping the peristaltic tube
The pump controller is delivered with a IDØ2.0mm Silicone tube.
Move the lever up to open the clamp and remove the clamp from the pump.
Insert the tube into the two tube holders on each side of the tube clamp and make sure the tube follows tangent and the arc of the clamp.
Push the tube clamp back onto the pump and lower the leverthe tube is now occluded by the rollers.
3.B. Releasing the peristaltic tube when you have finished
Whenever the pump is not in use for long periods of time it is important to release the pressure off the tube. This will reduce tube deformation and ensure that accuracy/precision is maximised.
Release the pressure by lifting the pressure lever
3.C. Replacing the tube
Tube need replacing when worn out or wherever you intend to change the dispense volume range in which you workfor smaller or larger dispense volumes.
Lift the pressure lever and replace the tube, making sure that you have installed the tube centrally and that the tube is fully engaged by the tube guides. .
Page 2
Pressure lever
Clamp
4. The choice of tubing
The unit can work either with fixed length tubing75mm long within the tube clamp, or with continuous tubing which in effect does not have any length restriction. In both cases, the correct tube clips have to be installed in the clamp.
For the continuous tubing there are three sizes of tube clips:.
1. Marked ‘1’ for ID1.0mm tube
2. Marked ‘2’ for ID 2.0mm tube
3. Marked ‘3’ for ID 3.0mm tube
Clip No. 2 is used for the fixed length tubing.
Page 3
5. The Control Panel
U/D keys
Scroll menu Choose range Increase or decrease value
when in calibration mode
Enter
STOP dispense
GO—start dispense
Back space/Escape