Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the
CAUTION!
The default password is used for your first login. To ensure account security, please change the
password after your first login. You are recommended to set a strong password (no less than eight
characters).
dealer.
Trademark Acknowledgement
The trademarks, company names and product names contained in this manual are the property of their respective
owners.
Disclaimer
To the maximum extent permitted by applicable law, the product described, with its hardware,
software, firmware and documents, is provided on an “as is” basis.
Best effort has been made to verify the integrity and correctness of the contents in this manual,
but no statement, information, or recommendation in this manual shall constitute formal
guarantee of any kind, expressed or implied. We shall not be held responsible for any technical
or typographical errors in this manual. The contents of this manual are subject to change
without prior notice. Update will be added to the new version of this manual.
Use of this manual and the product and the subsequent result shall be entirely on the user’s
own responsibility. In no event shall we be liable to you for any special, consequential,
incidental, or indirect damages, including, among others, damages for loss of business profits,
business interruption, or loss of data or documentation, or product malfunction or information
leakage caused by cyber attack, hacking or virus in connection with the use of this product.
Video and audio surveillance can be regulated by laws that vary from country to country. Check
the law in your local region before using this product for surveillance purposes. We shall not be
held responsible for any consequences resulting from illegal operations of the device.
The illustrations in this manual are for reference only and may vary depending on the version or
model. The screenshots in this manual may have been customized to meet specific
requirements and user preferences. As a result, some of the examples and functions featured
may differ from those displayed on your monitor.
This manual is a guide for multiple product models and so it is not intended for any specific
product.
Due to uncertainties such as physical environment, discrepancy may exist between the actual
values and reference values provided in this manual. The ultimate right to interpretation resides
in our company.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper
storage, use and disposal of this product, national laws and regulations must be observed.
Symbol
Description
WARNING!
Indicates a hazardous situation which, if not avoided, could result in bodily
injury or death.
CAUTION!
Indicates a situation which, if not avoided, could result in damage, data loss
or malfunction to product.
NOTE!
Indicates useful or supplemental information about the use of product.
Symbols
The symbols in the following table may be found in this manual. Carefully follow the instructions indicated by the
symbols to avoid hazardous situations and use the product properly.
3 System ································ ································································································ ·············· 2
Basic ··························································································································································· 2
Time ··························································································································································· 3
Serial ·························································································································································· 4
Device Status ············································································································································ 11
Maintenance ············································································································································ 13
i
1 Introduction
NOTE!
The default IP address of your device is 192.168.1.14; the default subnet mask is 255.255.255.0;
the default gateway is 192.168.1.1.
Use admin as the username and 123456 as the password for first-time login. Please change the
default password under admin to ensure account security.
This product is a high-performance video image processing workstation that can display multiple
dynamic screens on multiple displays to realize the window splicing function. This product,
designed specifically for high-quality multi-screen scenarios, features flexible control of different
types of screens with varied resolutions. It can be used in industries such as education and
research, government announcements, information publishing, administrative management,
military command, exhibition display, security monitoring, and home appliance sales.
This manual describes how to manage the device on a Web browser. The figures in this manual are
only for illustration purpose. The parameters, options and values actually displayed on the Web
pages of your device may be different from those in this manual.
2 Login
Before you start, check that:
The device is operating properly.
The computer is connected to the device.
The computer is installed with Microsoft Internet Explorer (IE) 7.0 or higher, and no proxy server is
being used.
Follow the steps to log in to the device:
1. Enter the device's IP address in the address bar and then press Enter.
1
2. Log in with the correct username and password.
3 System
Set system settings include Basic information, Time, Serial, Window, Running Mode and Security.
Basic
The Basic page lists the basic information including device type, serial number, software version,
hardware version and boot version.
1. Click System > Basic.
2
2. Click Refresh.
Time
Set system time for your device and how to update time.
1. Click System > Time.
2. Set the parameters. Some are described in the table below.
3
Parameter
Description
Time Zone
Choose a time zone for your device.
System Time
Current system time of the device.
Click the Set Time text box and then set the time manually, or select Sync with PC and then the device automatically synchronizes time with your computer.
Auto Update
Enable this function if you have a Network Time Protocol (NTP) server on the
network. The device synchronizes time with the NTP server at the set interval
when enabled.
The NTP server's IP address, port number, and update interval are required.
NTP Server Address
Enter the IP address of the NTP server
Note:
Set only when automatic update is enabled
NTP Port
Enter the port number of the NTP server
Note:
Set only when automatic update is enabled
Update Interval
The device time is updated every few minutes
Note:
the valid range of input time is 1~10080 minutes
only set when auto update is enabled
NOTE!
The device synchronizes time with the central server when operating in server mode.
Serial
Set the serial port on the device, including the number, serial mode, baud rate, date bit, stop bit
check bit and flow control method.
RS232
1. Click System > Serial > RS232.
2. The RS232 page lists the RS232 interface and can set parameters accordingly. The figure
below shows the RS232‘s parameters.
4
Parameter
Description
NO.
Select the serial port to set.
Serial Mode
Screen Controll.
Baud Rate
Transmission rate in bps.
The baud rate must be consistent with that on the connected external device.
Data Bit
Number of data bits per character.
Stop Bit
Number of stop bits per character.
Check Bit
Two kinds of parity bits: even parity bit or odd parity bit.
Flow Control
Whether and how to control flow of data through the serial port.
RS485
3. Click Save.
4. Some parameters are described in the table below.
1. Click System > Serial > RS485.
2. The RS485 page lists the RS485 interface and can set parameters accordingly. The figure
below shows the RS485‘s parameters.
5
3. Click Save.
Parameter
Description
NO.
Select the serial port to set.
Serial Mode
Screen Controll.
Duplex
Full duplex or half duplex.
Available in RS485 page.
Baud Rate
Transmission rate in bps.
The baud rate must be consistent with that on the connected external device.
Data Bit
Number of data bits per character.
Stop Bit
Number of stop bits per character.
Check Bit
Two kinds of parity bits: even parity bit or odd parity bit.
Flow Control
Whether and how to control flow of data through the serial port.
NOTE!
In server mode, only Duplex can be configured on the Web browser, and all the other parameters
can be configured only on the central server.
4. Some parameters are described in the table below.
Window
Set window border
1.System > Window.
6
2. Set the parameters. Some are described in the table below.
Parameter
Description
Boder
Off by default,Display window border after opening
Border Color
Set border color
Border Width
Set border width
3. Click Save.
Running Mode
Set the running mode and protocol of the device.
1. Click System > Running Mode.
2. The Running Mode page lists the running mode and protocol.
3. Click Save.
7
Security
Set the security of the device.
Telnet
Enable Telnet if you want to access the device from a computer with Telnet. By default the admin
username cannot be changed.
1. Click System > Security > Telnet.
2. Select the check box to enable Telnet, and then click Save.
SNMPv3
Through SNMP the central server synchronizes audio/video channel configurations and some of
the scheduled tasks to the device, and the device reports device alarms to the central server.
1. Click System > Security > SNMPv3.
2. This page can’t be configured.
8
Authentication
Parameter
Description
Friendly Password
You must log in with a strong password except in the same network segment
or three private network segments (10.X.X.X/8、172.16.X.X/12
、
192.168.X.X/16).
Enhanced Password
You must log in with a strong password.
Select digest or null in the Authentication page. Digest access authentication is one of the
agreed-upon methods a web server can use to negotiate credentials with server.
1. Click System > Security > Authentication.
2. Select Digest to enable the digest authentication, and then click Save.
Secure password
1. Click System > Security>Secure Password.
2. Select password mode ,and then click Save
3. Some parameters are described in the table below.
9
4 Network
Parameter
Description
Working Mode
Load Balance.
Select NIC1
Select the network interface.
IPv4 Address
Set the IP Address.
IPv4 Subnet Address
Set the subnet address.
IPv4 Default Gateway
Set the gateway.
MAC Address
Display the mac address.
Set network settings include TCP/IP and Telnet so that the device can communicate with other
devices on the network.
TCP/IP
Assign a static IP address manually, or obtain one using the DHCP server.
1. Click Network > TCP/IP.
2. Set the parameters. Some are described in the table below.
3. Click Save.
10
5 Maintenance
Parameter
Description
Device Status
View device information.
For more details, see Device Status.
Maintenance
Restart the device.
Restore factory default settings.
Import and export configuration file.
Export diagnostic information.
Upgrade the software.
For more details, see Maintenance.
The major functions provided on the Maintenance menu are listed in the table below.
Device Status
1. Click Maintenance > Device Status to view information of the device, its basic
information,running status,fan status and slot temperature. The following shows an example.
2. Some are described in the table below.
11
Parameter
Description
Model
The current product model equipment
Serial Number
Firmware Version
Hardware Version
Equipment hardware version of the current
Boot Version
Current versions of bootstrap equipment
Running Mode
The operation of the equipment for the current configuration mode
Access Mode
The current access mode of the equipment
Protocol
The current equipment access protocol
System Time
Equipment of the current system time
Running Time
Equipment continuous operation time
Temperature
The temperature of the current equipment
CPU Usage
Current CPU utilization device
Memory Usage
Equipment the current memory usage
Fan Status
If the current fan online
Fan Speed
The fan speed
Buzzer
On: When the high temperature alarm,the buzzer will beep
Off: When the high temperature alarm, the buzzer won't buzz
3. you can view the current boards in the icon types, such as temperature, whether online status
information
12
Maintenance
Click Maintenance > Maintenance and then perform maintenance operations as needed. You can
restart the device, restore some factory default settings, import and export configuration files,
export diagnostic information, and upgrade the device.
13
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.