MODELS 5304, 5304L, 2995, 2995L
OPERATIONAL SUMMARY
CONDITION OF ALARM AUDIBLE & VISUAL SIGNALS BEFORE SOLUTION / RECOMMENDATION
HORN RED LED GREEN LED
Silent
Silent
Blinks On once
approx every
40-45 seconds
Blinks On once approx every
40-45 seconds
Stays On
Off
SOLUTION / RECOMMENDATION
AC Power is present. DC Power is present.
AC Power is not present and alarm is receiving DC Power. Check the breaker or fuse box for
power. If the breaker or fuse box looks normal, call a licensed electrician for assistance.
Horn does not
sound when other alarms are active
or horn does not sound when
inter-connected alarm's test
button is pressed
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
3 Beeps,
2 second pause,
Repeat
Silent
(alarmed
previously)
Blinks On once
approx every
40-45 seconds
Blinks On
approx every
2 seconds
Off
Blinks On
approx every
2 seconds
Blinks On
approx every
2 seconds
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once approx every
10 seconds
(silence mode)
Stays On
or Off
Stays On
Stays On
Stays On Nuisance Alarm - If there is no hazard present, verify the alarm is mounted in the correct location
Stays On
Stays On
Press and hold the smoke alarm Test/Silence button for at least 5 seconds. If still no alarm, turn off
AC Power at the circuit breaker or fuse box and disconnect the alarm from the mounting bracket
and make sure the connector plug is securely attached on units that did not alarm. If still no alarm,
have a licensed electrician check to see if the yellow wire is connected to the neutral wire.
Originating Smoke Alarm - If hazard is identified, please take all precautions if an alarm sounds by
calling an Emergency Service and getting out of the home.
Non-originating Smoke Alarm - Another interconnected smoke alarm has sensed smoke, causing
all interconnected units to sound.
(see User's Manual, "AVOID THESE LOCATIONS" section). Reset alarm as instructed below.
Silence Feature is activated by pressing and releasing the Test/Silence button on the initiating
alarm while in alarm condition. Silence mode will last for approx 8-12 minutes.
QUICK FIND
alarm initiated the alarms to sound. The
locate the originating alarm (once the alarms have stopped sounding). To initiate
press the Test/Silence button on any alarm; and, after releasing the button, the originating alarm
will continue to sound for approx 60 seconds. Reset the originating alarm. NOTE: In a noninterconnected installation, it is necessary to test each alarm to determine the originating alarm.
®
Alarm Origination - In an interconnected system, it is difficult to determine which
QUICK FIND
®
feature will allow you to immediately
QUICK FIND
®
,
Silent
1 Chirp
approx every
40 seconds
Blinks On once
approx every
40-45 seconds
(normal operation
mode) or Blinks on once approx every
10 seconds
(silence mode)
Blinks On once
approx every
40-45 seconds
THIS PRODUCT IS LISTED TO UL ST ANDARD FOR SAFETY,
UL217 BY UNDERWRITERS LABORA TORIES, INC.
Stays On To Reset the Alarm - Hold the Test/Silence button for approx. 10 seconds. This will clear alarm
Stays On Low Battery - Check to make sure the battery activation pull tab has been completely removed,
origination. Reset after each smoke alarm event.
battery polarity is correct and the battery terminals are making contact with the smoke alarm
contacts in the battery drawer. If chirp continues, replace the 9V battery (see User's Manual for
recommended battery types).