Universal Scientific UNA850 User Manual

Page 1
Doc. Title
User Guide for UNA Module and Socket EVB (V23)
Max Shu
Date 2012/09/07 Version DVT V23
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 2
Revision Record
Version Revise content Date
1.0 New release 2012-08-10
1.1
1.Add EVB test point pin define
2.
Identification of PCB version
2012-09-07
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 3
Content
1. FCC Regulations............................................................................................3
2. RF Exposure Information..............................................................................4
3. Information of Installed Module....................................................................5
4. Guide to Use..................................................................................................6
1) Function of Socket EVB V23 and Identification of PCB version................6
2) Configure the Socket EVB............................................................................8
3) Insert the SIM card.....................................................................................11
4) Place the Module .......................................................................................12
5) Connect the antenna..................................................................................13
6) Download setting........................................................................................14
7) Manual control module sleep mode:...........................................................15
8) Apply External power to module.................................................................16
9) Measure current of module setting.............................................................17
10) Connect extend cable for line in & line out :................................................18
11) EVB test point pin define............................................................................19
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 4
1. FCC Regulations
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 5
2. RF Exposure Information
This Modular Approval is limited to OEM installation for mobile and fixed applications only. The antenna installation and operating configurations of this transmitter, including any applicable source-based time-averaging duty factor, antenna gain and cable loss must satisfy MPE categorical Exclusion Requirements of §2.1091.
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons, must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures.
The end user has no manual instructions to remove or install the device and a separate approval is required for all other operating configurations, including portable configurations with respect to 2.1093 and different antenna configurations.
Maximum antenna gain allowed for use with this device is 2 dBi. When the module is installed in the host device, the FCC ID label must be visible through a window on the final device or it must be visible when an access panel, door or cover is easily re-moved. If not, a second label must be placed on the outside of the final device that contains the following text: “Contains FCC ID: IXM-UNA850”.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 6
3. Information of Installed Module
Module Name FCC ID HW Version SW Version GSM Band UMTS Band GSM Feature GPRS EDGE UMTS Feature AT Command
UNA_850
IXM-UNA850
V2.3
V3.1a GSM 850, E-GSM 900, DCS 1800, PCS 1900 FDD I, FDD V Release 99 Release 6, Multi-slot class 12 Release 6, Multi-slot class 12 HSDPA, HSUPA (UMTS Release 6) 3GPP TS 27.007, 27.005
SIM/USIM Interface
Operating Temperature
Operating Voltage
Support 3V and 1.8V USB 2.0 high speed Frequency Stability covers operating
temperature range of -20° to +50°C
3.3 ~ 4.2V
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 7
4. Guide to Use
1) Function of Socket EVB V23 and Identification of PCB version
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 8
Function Description Available Unavailable
USB PORT Connect to Host PC and Download Firmware V Power supply IN Optional Connect to external Power supply input V UART1 Download Firmware V RF SMA connector Connect to external Antenna V SIM card Connect to SIM card V LINE IN Connect to Line in V LINE OUT Connect to Line out V J51 MP test connector V J52 MP test connector V
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 9
2) Configure the Socket EVB
Default JUMP Setting :
Component reference Function Jump 1-2
J40 J41
Enable VBAT_M. (Default) R808 short. Enable VBAT_M1.(Default) R809 short.
No, Note1 No, Note2
Note1 :For current measurement of VBAT_M: de-solder R808. Close J40 Note2 :For current measurement of VBAT_M1: de-solder R809. Close J41
Component reference Function Jump 1-2
J42
(Default) Output +3.3V for module No Output +4.2V for module Yes
Component reference Function Jump 1-2
J45 USB_EN high level input to turn on Module No J53 PWRKEY high level input to turn on Module No
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 10
Download Key :
Component reference Function Jump 1-2
J31 Enable Download through USB No, Note3
Note 3: To enable download mode, Please close J31 and refer to “ Use Data Card Tool To Update Image File Steps-V1.1-2012.07.18.pdf”
Jump setting for normal mode .
Component reference JUMP 1-2
J40 NO J41 NO J42 NO J31 NO J45 NO
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 11
J53 NO
Jump setting for Download mode :
Component reference JUMP 1-2
J40 NO J41 NO J42 NO J31 YES J45 NO J53 NO
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 12
3) Insert the SIM card
To use a UNA module, you need to install: a. A live SIM card (with an active account), or b. A test SIM card for use with call box (for example ,an Agilent 8960 ..)
To install the SIM card: a. Place the Socket EVB face-up(as shown) – the SIM slot is on right side. b. Note the location of the notched corner of the card in the following image.
c. Inset the SIM card into the slot.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 13
4) Place the Module
After inserting the SIM card, insert the module: a. Place the Socket EVB face-up(as shown) – the socket is in the center.
b. Notice the pin 1 location on the socket.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 14
5) Connect the antenna
After installing the Module ,connect the supplied antenna to the EVB a. Place the Socket EVB face-up. The antenna connector on the bottom side.
b. Connect the antenna to the adapter.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 15
6) Download setting
a. Plug in the Jump.
b.Connect the USB cable between EVB & PC.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 16
7) Manual control module sleep mode:
Component reference Function
J45 USB_EN input for sleep / normal mode
a. Follow UNA IO application design notes b. Plug in the Jump from J45 before use manual control. c. Connect J51,16pin to control module .
J51,16pin:
Hi(3.3~5.0V): Normal mode ; Low(0~0.3V): Sleep mode
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 17
8) Apply External power to module
To use external power for module, please follow the steps to setting. a. Red line VCC connect to J38. b. Black line GND connect to J39. c. De-solder the open pad R808.(yellow circle) d. USB cable connect to Host PC.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 18
9) Measure current of module setting
a. De-solder the open pad R809.(yellow circle)
b. Please follow the photo to setup the current meter.
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 19
10) Connect extend cable for line in & line out :
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 20
11) EVB test point pin define
1. J52 Pin define
Pin number Pin name
1 GND 3 DAICLK
5 DAIPCMOUT 7 SCL
9 SDA
11 Reserve Pin 13 URXD2 15 URXD1
Pin number Pin name
2 VBAT_M1 4 DAISYNC
6 DAIPCMIN
8 DAIRST 10 Reserve Pin 12 Reserve Pin
14 UTXD2 16 UTXD1
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.
Page 21
2.J51 Pin define
Pin number Pin name
1 GND 3 Wake
5 #EINT9 7 GPIO2
9 GPIO0
11 Reserve Pin 13 KROW0 15 Reserve Pin
Pin number Pin name
2 AP_Ready
4 #W_Disable
6 ID (
8 GPIO1 10 #Sys_config (
12 Reserve Pin 14 KCOL6 16 Reserve Pin
Note4)
Note5)
Note4: Default- open (900 module);If use 850 module, this pin to pull low(1kΩΩΩΩ). Note5: enable "USB+UART "mode-Default- open (USB only);If use”USB+UART” mode,
this pin to pull low(1kΩΩΩΩ).
The information contained herein is the exclusive property of Universal Scientific Industrial Co., Ltd. and shall not be distributed, reproduced, or disclosed in whole or in part without prior written permission of USI Co., Ltd.