OWNERS MANUAL
FORCED AIR NATURAL GAS CONSTRUCTION HEATER
Model
150-FASNG
QUESTIONS?
MISSING / DAMAGED PARTS
Please do not return this product to the store.
If a part is damaged or missing, simply e-mail us at
php@allpro-heaters.com, or visit our website at
STOP
http://allpro-heaters.com, or call our Customer
Service Department at (888) 619-7060.
We will be happy to assist you!
You can register your heater on line at
http://allpro-heaters.com/warranty.
TABLE OF CONTENTS
HEATER SPECIFICATIONS................................................................................................................ 2
WARNINGS .................................................................................................................................. 2
OPERATING PRECAUTIONS ............................................................................................................. 3
SAFETY PRECAUTIONS .................................................................................................................... 3
ODOR FADE WARNING ...................................................................................................................... 4
OPERATING INSTRUCTIONS ............................................................................................................ 5
SERVICING ......................................................................................................................................... 5
150-FASNG - PARTS ........................................................................................................................... 6
150-FASNG - WIRING DIAGRAM ........................................................................................................ 7
WARRANTY......................................................................................................................................... 8
SERVICE CENTERS .......................................................................................................................... 8
INSTRUCTIONS FOR ORDERING PARTS ........................................................................................ 8
WARRANTY REGISTRATION ............................................................................................................. 9
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
© 2002 Scheu Products Company
Model
150-FASNG
HEATER SPECIFICATIONS
Type of Gas: For use with Natural Gas Only
Gas Supply Pressure
to regulator Maximum: Minimum: 5" W.C. (1.25 kPa)
regulator out 4" W.C. (1.0 kPa)
Electrical Input: 115V, 60 Hz, 1Ø, 3a Minimum Operating Voltage: 100V
Ignition: Direct Spark, interrupted type
Primary Flame Control: Solid State, 10-15 Second Timing
High Temperature Control: 240°F (116°C) Minimum Ambient Temp. Rating 0°F (-17.8°C)
Model: 150-FASNG
Rating: 150,000 Btu/hr
(43.93 kW)
Fuel Consumption: 139 CuFt/HR
Fuel Orifice Port No.: 18
Fuel Orifice Port Size: 0.0595
1/2 psig (3.45 kPa)
Heated Air Output: 450 cfm
(12.74 cmm)
WARNINGS
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE
READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN
DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT
THE MANUFACTURER.
WARNING: NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING: FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS
BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED
BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN
CHEMICALS.
Scheu Products Company, Incorporated
Mail: P.O. Box 250, Upland, CA 91785
Plant: 8855 Baker Ave., Rancho Cucamonga, CA 91730
Telephone: 800-325-7057
www.scheuco.com
customerservice@scheuco.com
ANSIZ83.7/CGA2.14-2000
8688
September 2002
Page -2-
Model
150-FASNG
OPERATING PRECAUTIONS
This is a natural gas, direct-fired, forced air heater. It's intended
use is primarily temporary heating of buildings under
construction, alteration or repair.
If natural gas leaks from a connection or fitting, it mixes with
the surrounding air, forming a potentially explosive mixture.
Obviously, gas leaks should be avoided, so set up the gas
supply with utmost care. Read enclosed Odor Fade Sheet
for additional information about detecting gas leaks. Leak
check new connections or reconnections with a soap and
water solution and follow all connections instructions herein.
This heater was designed and certified for use as a
construction heater in accordance with ANSI Standard Z83.7/
CGA 2.14-2000. Check with your local fire safety authority if you
have any questions about your applications. Other standards
govern the use of fuel gases and heat producting products in
specific applications. Your local authority can advise you about
these.
Direct-Fired means that all of the combustion products enter the
heated space. Even though this heater operates very close to
100 percent combustion efficiency, it still produces small
amounts of carbon monoxide. Carbon monoxide (called CO) is
toxic. We can tolerate small amounts but not a lot. CO can build
up in a heated space and failure to provide adequate ventilation
could result in death. The symptoms of inadequate ventilation
are:
headache dizziness
burning eyes and nose nausea
dry mouth or sore throat
So, be sure to follow advice about ventilation in these operating
instructions.
SAFETY PRECAUTIONS
1. Check the heater thoroughly for damage. DO NOT operate a
damaged heater.
2. DO NOT modify the heater or operate a heater which has
been modified from its original condition.
3. Use only natural gas.
4. Provide at least 5" W.C. but not over 1/2 psig to the heater
inlet (regulator inlet).
5. Use an appropriate hose or flexible connector not over 10 ft.
(3.05m) in length.
6.Operate the heater only with the 4" W.C.regulator
provided by the factory.
7. For indoor use only. Area must be well ventilated. Figure 1.
(also see "Operating Precautions").
8. If at any time gas odor is detected, IMMEDIATELY
DISCONTINUE operation until the source of gas has been
located and corrected.
for additional information about detecting gas leaks.
10. Install the heater such that is is not directly exposed to water
spray, rain and/or dripping water.
11. Maintain minimum clearance from normal combustible
material (like paper). Figure 2.
12. Due to the high surface and exhaust temperatures, adults
and children must observe clearances to avoid burns or
clothing ignition.
13. Operate only on a stable, level surface.
14. Do not use with ductwork. Do not restrict inlet or exit.
15. Use only the electrical power specified. The electrical
connection and grounding must comply with National
Electrical Code - ANSI/NFPA 70.
16. Use only a properly grounded 3-prong receptacle and
extension cord.
17. Do not move, handle or service while hot or burning.
18. Use only in accordance with local codes.
Read enclosed Odor Fade Sheet
Forced Air means that a blower or fan pushes the air through
the heater. Proper combustion depends upon this air flow;
therefore, the heater must not be revised, modified or operated
with parts removed or missing. Likewise, safety systems must
not be circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other
people the user is responsible for properly acquainting those
present with the safety precautions and instructions, and of
the hazards involved.
VENTILATION: Minimum openings required
Heater near floor near ceiling
Infrared ............................................................... 1 ft
Convection (25-VC) ........................................... 1 ft
Convection (All others) ...................................... 2 ft
Radiant ................................................................ 2 ft
Forced air (30K-125K BTU/HR) .......................... 1 ft
Forced air (150-FAST, SPC-150T) .................... 2 ft
Forced air (3500-FACV, SPC-350) .................... 3 ft
Forced air (7000-FACV) .................................... 4 ft
Figure 1
Opening Opening
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
2
.....................
1 ft
1 ft
2 ft
2 ft
1 ft
2 ft
3 ft
4 ft
2
2
2
2
2
2
2
2
MINIMUM CLEARANCE: From normal combustible material
Figure 2
Radiant Forced Air
Clearance Infrared Convection Forced Air 7000-FACV
From floor ........................................................... 0 ft .............. 0 ft
From outlet .......................................................... 6 ft .............. 10 ft
From sides ................ 3 ft ............ 4 ft ............... 2 ft .............. 3 ft
From top ....................................... 6 ft ............... 3 ft .............. 5 ft
From front ................. 6 ft
From rear .................. 2 ft
Locate 10 ft. from canvas or plastic tarpaulins or similar coverings and
secure them to prevent flapping or movement due to wind action.
Page -3-