INSTALLATION INSTRUCTIONS &
Ultr a Series
Models:
UL2824
UL2830
UL2836
CONTENTS:
Part 1 - Planning The Installation
Part 2 - Electrical Connection
Part 3 - Direction of Vent and
Securing The Hood
Part 4 - Use & Care
USE & CARE GUIDE
Air-O® Ultra Series Range Hoods
READ AND SAVE THESE INSTRUCTIONS
Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and
service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Installer:
Owner:
Please leave these installation instructions with the range hood.
Please keep these installation instructions for local electrical inspector’s use a nd for future reference.
WARNINGS: Must be followed carefully to avoid personal injury
IMPORTANT: Must be followed carefully to avoid damage
TIPS: Contain helpful information
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS OBSERVE THE FOLLOWING:
• Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the
manufacturer.
• Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag to the service panel.
• Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction.
Item No. 0AL00-UL-001 Revised 10/05/04 Copyright (C) 2004, Universal Metal Industries, Inc. Page 1

WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
• Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) or fuel
burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
• When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
• Duct fans must always be vented to the outdoors.
WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
• Never leave surface units unattended at high settings. Boil-overs may cause smoking and greasy spillovers
that may ignite. Heat oils slowly on low or medium settings.
• Always turn hood ON when cooking at high heat or when cooking flaming foods.
• Clean filters and ventil ating fans frequently. Grease should not be allowed to accumulate on filter or fan.
• Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING! TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
• SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL
TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
• NEVER PICK UP A FLAMING PAN—you may be burned.
• DO NOT USE WATER, including wet dishcloths or towels—a violent steam explosion will result.
• Use an extinguisher ONLY if:
- You know you have a Class ABC extinguisher, and you already know how to operate it.
- The fire is small and contained in the area where it started.
- The fire department is being called.
- You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety Tips” published by the NFPA.
PART 1 Planning the Ins tall ation
CAUTION:
• For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
• To reduce the risk of fire and to properly exhaust air, the hood must be exhausted to outside air. Never
exhaust into a wall, an attic or a concealed area in the building. This can create a potential hazard.
• Consult a licensed ventilation contractor or qualified technician for proper installation of exhaust ducting.